This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Single or double deflection grilles with adjustable blades for S-COL R subcollectors
Brand
Cairox
Application
For air supply and exhaust in ventilation and air conditioning systems
Material
Steel
Colour
Standard colour white, RAL 9016
Other colours available upon request
Composition
SHN: Single row of adjustable blades
SHVN: Double row of adjustable blades
Mounting
Invisible mounting with clips in subcollector, type S-COL R
Accessories
Subcollector, type S-COL R
Text for tender
The air supply grilles for wall mounting have individually adjustable blades to regulate the direction of the air flow pattern. They are of the deflection type with an invisible clip fixing system and are supplied with a volume control damper. Powder coating finish white RAL 9016
Cairox Type SH(V)N
The air supply grilles for wall mounting have individually adjustable blades to regulate the direction of the air flow pattern. They are of the deflection type with an invisible clip fixing system and are supplied with a volume control damper. Powder coating finish white RAL 9016
Cairox Type SH(V)N
Order example
SHVN, 190 x 091 LxH
SHN = Grille type
190 = Length (see table)
091 = Height (see table)
Artikelen
Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
E-shop
J035520030010
FRESH-H-1/L/2P
2
AC
Horizontal
Left
J035520030012
FRESH-V-1/L/2P
2
AC
Vertical
Left
J035520030020
FRESH-H-2/L/2P
2
AC
Horizontal
Left
J035520030022
FRESH-V-2/L/2P
2
AC
Vertical
Left
J035520030030
FRESH-H-3/L/2P
2
AC
Horizontal
Left
J035520030032
FRESH-V-3/L/2P
2
AC
Vertical
Left
J035520030040
FRESH-H-4/L/2P
2
AC
Horizontal
Left
J035520030042
FRESH-V-4/L/2P
2
AC
Vertical
Left
J035520030050
FRESH-H-5/L/2P
2
AC
Horizontal
Left
J035520030052
FRESH-V-5/L/2P
2
AC
Vertical
Left
J035520030060
FRESH-H-6/L/2P
2
AC
Horizontal
Left
J035520030062
FRESH-V-6/L/2P
2
AC
Vertical
Left
J035520030070
FRESH-H-7/L/2P
2
AC
Horizontal
Left
J035520030072
FRESH-V-7/L/2P
2
AC
Vertical
Left
J035520031010
FRESH-H-1/R/2P
2
AC
Horizontal
Right
J035520031012
FRESH-V-1/R/2P
2
AC
Vertical
Right
J035520031020
FRESH-H-2/R/2P
2
AC
Horizontal
Right
J035520031022
FRESH-V-2/R/2P
2
AC
Vertical
Right
J035520031030
FRESH-H-3/R/2P
2
AC
Horizontal
Right
J035520031032
FRESH-V-3/R/2P
2
AC
Vertical
Right
J035520031040
FRESH-H-4/R/2P
2
AC
Horizontal
Right
J035520031042
FRESH-V-4/R/2P
2
AC
Vertical
Right
J035520031050
FRESH-H-5/R/2P
2
AC
Horizontal
Right
J035520031052
FRESH-V-5/R/2P
2
AC
Vertical
Right
J035520031060
FRESH-H-6/R/2P
2
AC
Horizontal
Right
J035520031062
FRESH-V-6/R/2P
2
AC
Vertical
Right
J035520031070
FRESH-H-7/R/2P
2
AC
Horizontal
Right
J035520031072
FRESH-V-7/R/2P
2
AC
Vertical
Right
J035520032010
FRESH-H-1/L/4P
4
AC
Horizontal
Left
J035520032012
FRESH-V-1/L/4P
4
AC
Vertical
Left
J035520032020
FRESH-H-2/L/4P
4
AC
Horizontal
Left
J035520032022
FRESH-V-2/L/4P
4
AC
Vertical
Left
J035520032030
FRESH-H-3/L/4P
4
AC
Horizontal
Left
J035520032032
FRESH-V-3/L/4P
4
AC
Vertical
Left
J035520032040
FRESH-H-4/L/4P
4
AC
Horizontal
Left
J035520032042
FRESH-V-4/L/4P
4
AC
Vertical
Left
J035520032050
FRESH-H-5/L/4P
4
AC
Horizontal
Left
J035520032052
FRESH-V-5/L/4P
4
AC
Vertical
Left
J035520032060
FRESH-H-6/L/4P
4
AC
Horizontal
Left
J035520032062
FRESH-V-6/L/4P
4
AC
Vertical
Left
J035520032070
FRESH-H-7/L/4P
4
AC
Horizontal
Left
J035520032072
FRESH-V-7/L/4P
4
AC
Vertical
Left
J035520033010
FRESH-H-1/R/4P
4
AC
Horizontal
Right
J035520033012
FRESH-V-1/R/4P
4
AC
Vertical
Right
J035520033020
FRESH-H-2/R/4P
4
AC
Horizontal
Right
J035520033022
FRESH-V-2/R/4P
4
AC
Vertical
Right
J035520033030
FRESH-H-3/R/4P
4
AC
Horizontal
Right
J035520033032
FRESH-V-3/R/4P
4
AC
Vertical
Right
J035520033040
FRESH-H-4/R/4P
4
AC
Horizontal
Right
J035520033042
FRESH-V-4/R/4P
4
AC
Vertical
Right
J035520033050
FRESH-H-5/R/4P
4
AC
Horizontal
Right
J035520033052
FRESH-V-5/R/4P
4
AC
Vertical
Right
J035520033060
FRESH-H-6/R/4P
4
AC
Horizontal
Right
J035520033062
FRESH-V-6/R/4P
4
AC
Vertical
Right
J035520033070
FRESH-H-7/R/4P
4
AC
Horizontal
Right
J035520033072
FRESH-V-7/R/4P
4
AC
Vertical
Right
Quick selection
SHN
SHVN
Qv
LxH
190 x 091
296 x 091
190 x 091
296 x 091
Ak
0.0092
0.0159
0.0073
0.0127
50
Vk
1.5
1.9
X0,25
1.5
1.7
Ps
1
1.6
Lw(A)
<20
<20
100
Vk
3
1.7
3.8
2.2
X0,25
3
2.3
3.4
2.6
Ps
4
1.3
6.3
2.1
Lw(A)
<20
<20
24
<20
150
Vk
4.5
2.6
5.7
3.3
X0,25
4.6
3.5
5.1
3.9
Ps
8.9
3
14.2
4.7
Lw(A)
30
<20
35
22
200
Vk
6
3.5
7.6
4.4
X0,25
6.1
4.6
6.8
5.2
Ps
15.9
5.3
25.3
8.3
Lw(A)
37
25
42
30
250
Vk
7.5
4.4
5.5
X0,25
7.6
5.8
6.5
Ps
24.9
8.3
13.1
Lw(A)
43
31
36
300
Vk
5.2
6.6
X0,25
7
7.8
Ps
12
18.8
Lw(A)
36
41
400
Vk
7
X0,25
9.3
Ps
21.4
Lw(A)
44
Symbols and specifications
LxH = Width L and height H in mm
Q = Air volume in m³/h
Ak = Effective surface (free area) in m²
Vk = Average effective velocity through the grill in m/s
X0.25 = Horizontal throw in m at an endvelocity Vt of 0.25 m/s
Ps = Static pressure loss given in Pa
Lw(A) = Acoustic power in dB(A)
The throw X0.25 is given without deflection of the airstream at an end velocity of 0.25m/s. The distances are given for a smooth ceiling and installation distance of the center of the grille at 300mm from the ceiling surface. When mounted at a distance of 400 to 600 mm from the ceiling, a horizontal deflection towards the ceiling of 15° is advised. When mounted at a distance larger than 600mm from the ceiling, the throw distance X0.25 will be smaller than mentioned due to the missing coanda effect. In these cases and for all other special requirements, please contact our engineering office.
The values are given for isothermal supply air. Throw distances for cooling conditions at -11K can be calculated by dividing the X0.25 values with factor 1.1. For heating purposes at Dt of +11K a multiplier of 1.1 should be applied to the given X0.25 value.
Advised mounting distance between centers of multiple grilles in the same wall should be greater than 1/3 of the throw length X0.25 (without spread)
The pressure losses Ps are given for grilles without damper of with fully opened damper.
The acoustic powers Lw(A) are given for grilles without damper of with fully opened damper without room attenuation. Acoustic powers below 20dB(A) are mentioned as "<20" in the tables.