PS/RWR-FCSA (RAL9016) • Square swirl diffusers with fixed curved blades for suspended ceilings

Swirl ceiling diffusers with high induction rate, consisting of a square plate for for suspended ceilings with multiple fixed blades arranged in a circular pattern, to be equipped with galvanized steel plenum box.

Brand

  • CAIROX

Application

  • For air supply and exhaust in ventilation and air conditioning systems

Material

  • Steel

Colour

  • Standard colour white, RAL 9016
  • Other colours available upon request

Composition

  • Front plate made of powder coated steel
  • Central screw mounting

Mounting

  • Fixing by central screw in the crossbar of the plenum box

Accessories

  • Square plenum box, type REV-B
  • Square insulated plenum box, type REV-B ISO
  • Circular plenum box, type RER-B
  • Insulated circular plenum box, type RER-B ISO
  • Regulating valve for plenum box,type CRC
  • Polystyrene plenum box, type PPS-P with duct connection PPS-APD and mounting bar PPS-MB

Text for tender

Copy
  • The air supply ceiling diffusers are square with a circular arranged swirl with fixed curved blades. They are made of a steel powdercoated frontplate in white finish RAL 9016. The diffusers are standard delivered with galvanized steel plenumbox equipped with perforated plate and damper in the side entry spigot. The diffuser is centrally screw mounted.
  • Cairox type PS/RWR-FCSA + RER-B(ISO) + CRC

Order example

  • PS/RWR-FCSA, 400 + RER-B 400 + CRC 200

Explanation

PS/RWR-FCSA = Diffuser type

400 = Diffuser size

Accessories

RER-B = Plenum box type

400 = Size plenum box

CRC = Regulating valve for plenum box
200 = Plenum box connection diameter 200

Dimensions

 D [mm]D1 [mm]D2 [mm]D3 [mm]#Blades
PS/RWR-FCSA 30023810023659616
PS/RWR-FCSA 40033815033659622
PS/RWR-FCSA 50043815043659624

Quick selection

PS/RWR-FCSA300400500
QAk0.0230.030.0465
B1.22.43.61.22.43.61.22.43.6
100 H=2.70.170.130.11      
VzH=3.20.140.110.09      
 H=3.80.110.090.08      
Vk1.2  
X0,250.9  
Ps7  
Lw(A)<20  
150 H=2.70.260.20.160.230.180.15   
VzH=3.20.20.170.140.180.150.13   
 H=3.80.170.140.120.150.130.12   
Vk1.81.4 
X0,251.61.3 
Ps175 
Lw(A)26<20 
200 H=2.70.340.260.210.290.230.20.210.170.14
VzH=3.20.270.220.190.240.20.170.170.150.13
 H=3.80.220.190.160.20.170.150.150.130.12
Vk2.41.91.2
X0,252.21.91.1
Ps3082
Lw(A)34<20<20
250 H=2.70.430.330.270.360.290.240.250.20.17
VzH=3.20.340.280.230.30.250.210.210.180.16
 H=3.80.280.230.20.250.210.190.180.160.14
Vk32.31.5
X0,252.92.51.5
Ps47133
Lw(A)4124<20
300 H=2.70.510.390.320.430.340.280.290.240.2
VzH=3.20.410.330.280.350.290.250.250.210.18
 H=3.80.330.280.240.290.250.220.210.180.17
Vk3.62.81.8
X0,253.73.21.9
Ps67195
Lw(A)4730<20
400 H=2.7   0.560.440.370.380.310.26
VzH=3.2   0.460.380.330.320.270.24
 H=3.8   0.380.330.290.270.240.21
Vk 3.72.4
X0,25 4.72.9
Ps 339
Lw(A) 3921
500 H=2.7   0.690.540.460.460.380.32
VzH=3.2   0.560.470.410.390.330.29
 H=3.8   0.470.410.360.330.290.26
Vk 4.63
X0,25 6.44
Ps 5114
Lw(A) 4528
600 H=2.7      0.540.440.38
VzH=3.2      0.450.390.34
 H=3.8      0.390.340.31
Vk  3.6
X0,25  5.2
Ps  20
Lw(A)  34
800 H=2.7      0.70.570.49
VzH=3.2      0.590.50.44
 H=3.8      0.50.440.39
Vk  4.8
X0,25  7.9
Ps  35
Lw(A)  43

Symbols and specifications

  • Q = Air volume in m³/h
  • Ak = Effective surface (free area) in m²
  • B = Distance between the diffusers in m
  • H = Installation height of the diffusers in m
  • Vz = Maximum velocity at the occupied zone according to distance between the diffusers and installation height in m/s
  • Vk = Average effective velocity through the diffuser in m/s
  • X0.25 = Throw length in m at an end velocity Vt of 0,25m/s
  • Ps = Static pressure loss given in Pa
  • Lw(A) = Acoustic power in dB(A)


  • The throw X0.25 is given at an end velocity of 0.25m/s for a smooth ceiling without any obstacles.
  • The values are given for isothermal supply air. Throw distances for cooling conditions at -11K can be calculated by dividing the X0.25 values with factor 1.1. For heating purposes at Dt of +11K a multiplier of 1.1 should be applied to the given X0.25 value.
  • In order to achieve a high comfort level, selections can be made according to the maximal velocity at the occupied zone Vz. These values are given at distances between diffusers B and installation heights H. Velocities Vz lower than, or equal to 0,25m/s at the occupied zone are advised.
  • The pressure losses Ps are given for diffusers without damper of with fully opened damper.
  • The acoustic power values Lw(A) are given for diffusers without damper of with fully opened damper without room attenuation. Acoustic powers below 20dB(A) are mentioned as "<20" in the tables.
  • For all special requirements, please contact our engineering office.


Placement instruction

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...