Welcome to CAIROX BELGIUM
BFSA-I EC • Extra flat fan box with EC motor
- Insulated fan boxes
- 25 mm insulation
- Direct driven
- EC motor
Sound-dampening centrifugal fan box with EC motor and safety switch, with or without pressure controlled or constant flow regulation (Regulo)
Application
- Ventilation in rooms with little available space that require a low noise level, such as offices, restaurants, hotels,…
- Convenient for indoor or outdoor mounting
- Convenient for air supply and extraction
Composition
- Housing in galvanized plate steel
- Removable cover by screws for maintenance
- Integrated thermal protection
- Isolation: 25 mm rockwool (50-62 kg/m³)
- Fire class A1 according to EN13501-1
- Mounting feet with fastening
- Round connections with sealing on the air supply and extraction
- Integrated operating switch IP65 with lock standardly provided
- Equipped with built-in potentiometer for one-off speed setting
- Turnbuckle for electric supply of the motor directly on the operation switch
Fan
- Non residential ventilation unit with single flow direction
- Housing and spiral casing in galvanized plate steel 10/10
- Centrifugal ventilator with backward curved impeller
- Electric supply: mono phased 230V
- Integrated thermal safety device
- Soft start
- Modulating flow rate:
- Constant flow regulation (regulation by 0-10V signal) for model BFSA-I EC
- Constant pressure or constant flow regulation (to decide on-site) for model BFSA-I EC REGULO
- Integrated speed controller on the fan (only models with REGULO)
Accessories
- Potentiometer, type ESCP010 (for model without REGULO)
- Supple connection pieces, type MTS
Air performance data
|
|
BFSAHP-I EC 125 - 160 | - | 460 | 328 | 298 | 186 | BFSAHP-I EC 200 - 250 | - | 1050 | 919 | 788 | 588 | BFSA-I EC 315 | 1544 | 1320 | 981 | 254 | - | BFSA-I EC 355 | 1797 | 1721 | 1566 | 1419 | 1296 | BFSA-I EC 400 | 2925 | 2849 | 2601 | 2219 | 1782 |
Selection curves
- Value in circle = Sound pressure Lpa in dB (A) at a distance of 4 m in the free field, suction connected
- Value in square = Sound power LwA in dB (A) on the suction
- Q [m³/h] = Air flow
- Ps [Pa] = Static pressure
- P [W] = Absorbed power
Technical data
|
|
BFSAHP-I EC 125-160 | 230 | 95 | 0.73 | ESCP010 | 40°C | -20°C | IP 44 / B | 64 | 58 | 64 | BFSAHP-I EC 200-250 | 230 | 180 | 1.6 | ESCP010 | 40°C | -20°C | IP 44 / B | 64 | 60 | 65 | BFSA-I EC 315 | 230 | 105 | 0.75 | ESCP010 | 40°C | -20°C | IP 44 / B | 66 | 64 | 67 | BFSA-I EC 355 | 230 | 400 | 1.9 | ESCP010 | 40°C | -20°C | IP 44 / B | 67 | 65 | 67 | BFSA-I EC 400 | 230 | 1074 | 4.62 | ESCP010 | 40°C | -20°C | IP 44 / B | 79 | 74 | 75 |
- SCP = Potentiometer 0-10V
- ** Potentiometer only applicable to models without REGULO
- Tu = Maximum ambient temperature
- To = Minimum operating temperature
- Lwa 2 = Casing sound power level
- Lwa 5 = Sound power level @inlet
- Lwa 6 = Sound power level @outlet
Dimensions
|
BFSAHP-I EC 125-160 | 400 | 400 | 360 | 200 | 125/160 | 23 | 11 | BFSAHP-I EC 200-250 | 500 | 400 | 360 | 300 | 200/250 | 23 | 14.5 | BFSA-I EC 315 | 540 | 550 | 510 | 380 | 315 | 23 | 17 | BFSA-I EC 355 | 640 | 600 | 560 | 420 | 355 | 23 | 20 | BFSA-I EC 400 | 640 | 600 | 560 | 470 | 400 | 23 | 26.5 |
|