PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

MVX-DX • Direct expansion coil module

  • Cooling modules
  • DX-cooling module
  • 25mm insulation

Direct expansion coil module

Composition

  • Battery with copper tubes and aluminium fins, mounted on sliding rails - Suitable for R32 and R410A
  • Integrated drop separator (separator pressure loss see curves). See the datasheet MVX-BF for the pressure loss graph
  • Integrated condensation tray mounted on sliding rails
  • Positioning of the module: horizontal
  • Supplied as a separate component, unmounted; factory mounted upon request
  • Outer panel: pre-painted sheet steel (RAL 9007) with protective film

Connections of the battery

  • Intake: male, by welding (expansion valve not supplied)
  • Exhaust: male tube, welding
  • Condensates: hydraulic mail piping in steel tube at gas thread
  • Connection side: on the right, in the sense of the air flow direction (on the left on request)

Selection table

TypeV[l]INOUT
MVX-4DX11/25/8
MVX-5DX1,93/41"1/8
MVX-6DX3,13/41"1/8
MVX-7DX4,67/81"3/8
MVX-8DX7,21"1/81"5/8
MVX-9DX10,61"1/81"5/8

Approximate volume of batteries with 1/4 in the liquid phase and 3/4 in the gaseous phase

Selection table cooling

 Tev [°C]Ta,i/RH [°C/%]

*Qv,a [m³/h]
400600800100012001300-
∆P [Pa]20385985112123
MVX-4 DX732/40P [kW]/ Ta,o - RH [°C - %]3,37/14,6-824,08/17,0-784,47/18,7-764,62/20,0-754,58/21-744,6/21,5-75-
Qv,R410A [l/h] / Dp,R410A [kPa]68/10,782/15,290/17,993/18,993/18,693/19-
27/50P [kW]/ Ta,o - RH [°C - %]2,72/13,5-863,28/15,5-833,6/16,8-823,73/17,8-813,73/18,6-803,69/19,0-80-
Qv,R410A [l/h] / Dp,R410A [kPa]55/7,366/10,273/12,175/12,975/12,975/12,9-
25/50P [kW]/ Ta,o - RH [°C - %]2,23/13,0-852,63/14,8-832,83/16,0-812,86/16,9-812,89/17,6-792,99/17,9-77-
Qv,R410A [l/h] / Dp,R410A [kPa]45/5,153/6,957/7,858/858/8,160/8,7-
532/40P [kW]/ Ta,o - RH [°C - %]3,77/13,2-824,64/15,8-795,17/17,7-775,45/19,0-755,53/20,2-745,51/20,6-74-
Qv,R410A [l/h] / Dp,R410A [kPa]76/13,994/20,2105/24,6110/27112/27,7112/27,5-
27/50P [kW]/ Ta,o - RH [°C - %]3,12/12,1-863,84/14,2-844,29/15,7-824,55/16,9-814,66/17,7-804,67/18,1-80-
Qv,R410A [l/h] / Dp,R410A [kPa]63/9,978/14,387/17,592/19,595/20,495/20-
25/50P [kW]/ Ta,o - RH [°C - %]2,63/11,6-863,19/13,5-833,52/14,9-823,67/15,9-813,7/16,7-803,68/17,1-80-
Qv,R410A [l/h] / Dp,R410A [kPa]53/7,365/10,371/12,374/13,375/13,475/13,3-
Tev [°C]Ta,i/RH [°C/%]
*100012001400160018002000
∆P [Pa]567696118139162
MVX-5 DX732/40P [kW]/ Ta,o - RH [°C - %]8,1/15-828,92/16-819,45/16,9-809,83/17,8-7910,1/18,5-7810,2/19,2-77-
Qv,R410A [l/h] / Dp,R410A [kPa]162/12,9180/15,5190/17,3198/18,5203/19,4206/19,9-
27/50P [kW]/ Ta,o - RH [°C - %]6,59/13,7-867,14/14,7-857,57/15,4-847,88/16,1-838,09/16,7-838,21/17,2-82-
Qv,R410A [l/h] / Dp,R410A [kPa]133/9144/10,4152/11,6159/12,4163/13166/13,4-
25/50P [kW]/ Ta,o - RH [°C - %]5,37/13,2-865,76/14-856,04/14,7-846,22/15,3-836,32/15,9-836,34/16,3-82-
Qv,R410A [l/h] / Dp,R410A [kPa]108/6,2116/7,1122/7,7125/8,1127/8,3128/8,4-
532/40P [kW]/ Ta,o - RH [°C - %]9,21/13,4-8310,1/14,7-8110,8/15,7-8011,3/16,6-7911,7/17,4-7812/18,1-77-
Qv,R410A [l/h] / Dp,R410A [kPa]187/17,5204/20,6218/23,2229/25,3237/26,9243/28,1-
27/50P [kW]/ Ta,o - RH [°C - %]7,6/12,3-878,32/13,4-868,89/14,2-859,34/14,9-849,69/15,6-839,95/16,1-83-
Qv,R410A [l/h] / Dp,R410A [kPa]154/12,3168/14,5180/16,4189/17,9196/19,1202/20,1-
25/50P [kW]/ Ta,o - RH [°C - %]6,39/11,8-866,94/12,7-857,36/13,5-847,68/14,2-837,91/14,8-838,06/15,3-82-
Qv,R410A [l/h] / Dp,R410A [kPa]129/9141/10,5149/11,7156/12,6160/13,3163/13,7-
Tev [°C]Ta,i/RH [°C/%]
*140018002200260030003200
∆P [Pa]466894121149163
MVX-6 DX732/40P [kW]/ Ta,o - RH [°C - %]12,3/13,9-8314/15,5-8115,2/16,8-8015,9/17,8-7916,4/18,7-7816,5/19,1-77-
Qv,R410A [l/h] / Dp,R410A [kPa]249/12,9282/16,1305/18,6321/20,4331/21,5333/21,8-
27/50P [kW]/ Ta,o - RH [°C - %]9,93/13-8711,2/14,3-8512,1/15,3-8412,8/16,1-8313,2/16,8-8313,3/17,1-82-
Qv,R410A [l/h] / Dp,R410A [kPa]200/8,7226/10,8245/12,5258/13,7266/14,5268/14,7-
25/50P [kW]/ Ta,o - RH [°C - %]8,15/12,5-869,1/13,7-859,73/14,6-8410,1/15,4-8310,3/16-8310,3/16,3-82-
Qv,R410A [l/h] / Dp,R410A [kPa]164/6,1183/7,4196/8,4204/9207/9,3208/9,3-
532/40P [kW]/ Ta,o - RH [°C - %]13,8/12,5-8415,7/14,2-8217,2/15,5-8018,3/16,7-7919,1/17,6-7819,3/18,1-77-
Qv,R410A [l/h] / Dp,R410A [kPa]279/16,6319/21,1349/24,9371/27,8386/29,9392/30,7-
27/50P [kW]/ Ta,o - RH [°C - %]11,4/11,5-8813/12,9-8613/12,9-8615,2/15-8415,8/15,7-8316,1/16,1-83-
Qv,R410A [l/h] / Dp,R410A [kPa]230/11,8263/15263/15307/19,8321/21,4326/22-
25/50P [kW]/ Ta,o - RH [°C - %]9,61/11,1-8710,9/12,4-8511,8/13,4-8412,5/14,2-8312,9/14,9-8313,1/15,2-82-
Qv,R410A [l/h] / Dp,R410A [kPa]195/8,7220/10,9239/12,6253/13,9262/14,8264/15,1-
Tev [°C]Ta,i/RH [°C/%]
*2000250030003500400045004700
∆P [Pa]415979102126152160
MVX-7 DX732/40P [kW]/ Ta,o - RH [°C - %]18,2/13,5-8420,5/14,9-8222,2/16-8023,5/17-7924,4/17,9-7825/18,6-7825,1/18,9-77
Qv,R410A [l/h] / Dp,R410A [kPa]385/17,7432/21,8469/25,3496/28515/29,9527/31,2530/31,5
27/50P [kW]/ Ta,o - RH [°C - %]14,7/12,6-8716,5/13,7-8617,9/14,7-8519/15,4-8419,7/16,1-8320,2/16,7-8320,4/16,9-82
Qv,R410A [l/h] / Dp,R410A [kPa]311/12348/14,8378/17,1400/19416/20,3426/21,3429/21,6
25/50P [kW]/ Ta,o - RH [°C - %]12,2/12,2-8713,5/13,2-8514,5/14-8415,2/14,7-8415,6/15,3-8315,9/15,9-8315,9/16,1-82
Qv,R410A [l/h] / Dp,R410A [kPa]256/8,5285/10,3306/11,7320/12,7330/13,4335/13,8336/13,8
532/40P [kW]/ Ta,o - RH [°C - %]20,3/12,0-8522,9/13,5-8325/14,8-8126,7/15,8-8027,9/16,8-7928,8/17,6-7829,1/17,9-78
Qv,R410A [l/h] / Dp,R410A [kPa]429/22,6486/28,3531/33,2566/37,2592/40,4612/42,8617/43,5
27/50P [kW]/ Ta,o - RH [°C - %]16,8/11,1-8819/12,4-8720,8/13,4-8522,2/14,2-8423,3/15,0-8424,1/15,6-8324,3/15,9-83
Qv,R410A [l/h] / Dp,R410A [kPa]356/16,1403/20,1440/23,6470/26,6493/29511/30,9516/31,5
25/50P [kW]/ Ta,o - RH [°C - %]14,2/10,7-8716/11,8-8617,4/12,8-8518,4/13,5-8419,2/14,2-8319,7/14,8-8319,9/15,0-82
Qv,R410A [l/h] / Dp,R410A [kPa]302/12339/14,8368/17,1390/19407/20,5418/21,6422/21,9
Tev [°C]Ta,i/RH [°C/%]
*300040005000600070007400
∆P [Pa]386189119151162
MVX-8 DX732/40P [kW]/ Ta,o - RH [°C - %]28/13,1-8432,6/15-8235,8/16,4-8038/17,6-7939,3/18,5-7839,6/18,9-77-
Qv,R410A [l/h] / Dp,R410A [kPa]564/19,4657/25,4722/30,2766/33,6792/35,6797/36,1-
27/50P [kW]/ Ta,o - RH [°C - %]22,6/12,3-8826,3/13,8-8628,9/14,9-8430,8/15,8-8331,9/16,6-8332,2/16,9-82-
Qv,R410A [l/h] / Dp,R410A [kPa]456/13,2530/17,3583/20,5620/22,9643/24,5649/24,9-
25/50P [kW]/ Ta,o - RH [°C - %]18,7/11,9-8721,5/13,2-8523,4/14,3-8424,5/15,1-8325,1/15,8-8325,1/15,8-83-
Qv,R410A [l/h] / Dp,R410A [kPa]378/9,4434/12471/14495/15,3506/15,9506/15,9-
532/40P [kW]/ Ta,o - RH [°C - %]31/11,7-8536,4/13,6-8240,4/15,2-8043,3/16,4-7945,2/17,5-7845,7/17,9-78-
Qv,R410A [l/h] / Dp,R410A [kPa]628/24,6738/32,9819/39,8877/45916/48,7927/49,7-
27/50P [kW]/ Ta,o - RH [°C - %]25,7/10,8-8930,2/12,4-8633,6/13,7-8536,1/14,7-8437,8/15,6-8338,4/15,9-83-
Qv,R410A [l/h] / Dp,R410A [kPa]521/17,6612/23,5680/28,5731/32,4766/35,3777/36,2-
25/50P [kW]/ Ta,o - RH [°C - %]21,9/10,4-8825,5/11,9-8628,1/13--8429,9/14-8331,1/14,7-8331,4/15-82-
Qv,R410A [l/h] / Dp,R410A [kPa]443/13,1516/17,3568/20,6605/23,1630/24,7636/25,2-
Tev [°C]Ta,i/RH [°C/%]
*60007000800090001000011000
∆P [Pa]6482101122145172
MVX-9 DX732/40P [kW]/ Ta,o - RH [°C - %]48,5/15,0-8251,9/16,0-8054,5/16,9-7956,4/17,6-7957,8/18,3-7858,6/18,9-77-
Qv,R410A [l/h] / Dp,R410A [kPa]978/261046/29,31099/321137/34,11164/35,61180/36,5-
27/50P [kW]/ Ta,o - RH [°C - %]39,2/13,9-8641,9/14,6-8544,1/15,3-8445,7/15,9-8346,9/16,4-8347,7/16,9-82-
Qv,R410A [l/h] / Dp,R410A [kPa]790/17,7845/19,9888/21,8921/23,3945/24,4961/25,1-
25/50P [kW]/ Ta,o - RH [°C - %]32/13,3-8534/14,0-8435,4/14,6-8436,4/15,2-8337,1/15,6-8337,3/16,1-82-
Qv,R410A [l/h] / Dp,R410A [kPa]646/12,3685/13,7714/14,7734/15,5747/16752/16,2-
532/40P [kW]/ Ta,o - RH [°C - %]54,2/13,7-8258,4/14,8-8161,7/15,7-8064,3/16,5-7966,3/17,3-7867,7/17,9-77-
Qv,R410A [l/h] / Dp,R410A [kPa]1099/33,71183/38,41250/42,513,3/45,81343/48,31372/50,2-
27/50P [kW]/ Ta,o - RH [°C - %]45/12,5-8648,5/13,4-8551,3/14,1-8453,6/14,8-8455,4/15,4-8356,8/15,9-83-
Qv,R410A [l/h] / Dp,R410A [kPa]912/24982/27,51040/30,51086/331123/351151/36,6-
25/50P [kW]/ Ta,o - RH [°C - %]37,9/12,0-8640,6/12,7-8542,7/13,4-8444,4/14-8345,6/14,6-8346,5/15,1-82-
Qv,R410A [l/h] / Dp,R410A [kPa]768/17,6823/19,9866/21,9899/23,4924/24,6942/25,5-

Selection table heating

 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

Qv,a [m³/h]
400600800100012001300
∆P [Pa]20385985112123
MVX-4 DX4011P [kW]3,194,1855,76,326,6
Ta,o [°C]34,231,229,127,526,325,7
15P [kW]2,723,554,244,845,365,6
Ta,o [°C]3532,530,629,328,227,7
 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

100012001400160018002000
 ∆P [Pa]567696118139162
MVX-5 DX4011P [kW]7,858,859,7710,611,412,1
Ta,o [°C]33,832,431,330,329,428,6
15P [kW]6,77,58,399,710,3
Ta,o [°C]34,733,532,531,0630,830,2
 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

140018002200260030003200
 ∆P [Pa]466894121149163
MVX-6 DX4011P [kW]11,513,615,517,218,719,4
Ta,o [°C]34,83331,530,229,128,6
15P [kW]9,7811,613,214,615,916,5
Ta,o [°C]35,63432,631,530,630,2
 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

200025003000350040004500
 ∆P [Pa]415979102126152
MVX-7 DX4011P [kW]16,819,622,124,426,428,3
Ta,o [°C]35,433,832,431,230,229,3
15P [kW]14,316,718,820,722,424,1
Ta,o [°C]36,134,733,532,431,630,8
 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

300040005000600070007400
 ∆P [Pa]386189119151162
MVX-8 DX4011P [kW]25,731,336,240,544,345,8
Ta,o [°C]35,933,73230,629,429
15P [kW]21,926,730,834,437,738,9
Ta,o [°C]36,634,733,231,930,930,5
 Tev [°C]Ta,i [°C]

Qv,a [m³/h]

60007000800090001000011000
 ∆P [Pa]6482101122145172
MVX-9 DX4011P [kW]46,551,455,96063,967,4
Ta,o [°C]33,532,331,330,429,528,8
15P [kW]39,643,747,55154,357,3
Ta,o [°C]34,533,432,531,73130,4

  • Tev = Evaporation temperature R410A
  • Ta,i = Temperature air before the coil
  • P = Total power
  • Ta,o = Temperature air after the coil
  • RH = Relative humidity
  • Qv,R410A = Flow refrigerant R410A
  • Dp, R410A = Pressure loss refrigerant R410A

Dimensions

 

A [mm]

B [mm]

C [mm]

G [mm]

I [mm]

J [mm]

K [mm]

L [mm]

M [mm]

ØUE [mm]

ØUS [mm]

ØW [mm]

[kg]

MVX-DX 4

44554544511510513590757512161/232

MVX-DX 5

5455455459514013090757518281/240

MVX-DX 6

64564564513517513590757518281/255

MVX-DX 7

74574574513515514095757522351/277

MVX-DX 8

845845970145185150110757528421/2107
MVX-DX 99459451170145175150110757528421/2140
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...