These fans are suitable for extraction of aggressive gasses.
They are particularly applicable for the extraction in:
Laboratia
Chemical and petrochemical industry
Metal treatment industry
Food and beverage industry
Water treatment systems
Composition
The casing is made of fire resistant polyethylene (PEs/PE-FR,RAL7036)
The housing is fitted with a splinter guard and condensate drain at its deepest point
The impeller is made of fire-resistant polypropylene (PPs/PP-FR) and is of the backward-curved blade type, statically and dynamically balanced according to Q 6.3 (VDI 2056)
In the case of direct drive, the impeller is directly mounted on the motor shaft by a Taperlock bush
The impeller can be demounted without removing the housing
Squirel cage asynchronous motor
Motor with PTC for use with frequency inverter
Supply: 400Vac 3ph 50 Hz
Protection: IP55
Insulation class: F
Accessories
Flexible connections made of PVC, type PVC
Set anti-vibration mounth, type AVM
Safety switch, type SCHALTER
Motor protection cover, type KC
Frequency controller 3x400V, type FIS(-C)-44-B
Options
ATEX version in accordance with directive ATEX 94/9/CE:
ATEX 3G (ATEX zone 2 inside/outside)
ATEX 2G (ATEX zone 1 inside/outside) with PE-el housing and PP-el impeller for diameters: HF R 125, 160, 200, 250, 315, 400 en 500
Two speed motors
230Vac (plug&play - not suitable for transformer and frequency control)
Other available products
These HF R fans are just a few of the very wide range of HF-fans. For a selection and price, perfectly tailored to your project, please send your request to engineering@cairox.be.
Order example
HF R 160-17D 400V 1500 rpm GR090
HF R = type of fan
160 = diameter
17 = type of impeller
D = direct driven / R = belt driven
400V = supply
1500 rpm = speed
GR090 = casing orientation
Artikelen
Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number
Type
Cooling capacity [kW]
Heating Capacity* [kW]
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
E-shop
J035530012010
UTV-10/L/2P
3.83
5.02
2
AC
Vertical
Left
J035530012020
UTV-20/L/2P
7.05
8.61
2
AC
Vertical
Left
J035530012030
UTV-30/L/2P
9.2
11.3
2
AC
Vertical
Left
J035530012040
UTV-40/L/2P
10.6
12.94
2
AC
Vertical
Left
J035530012050
UTV-50/L/2P
13.1
16.99
2
AC
Vertical
Left
J035530013010
UTV-10/R/2P
3.83
5.02
2
AC
Vertical
Right
J035530013020
UTV-20/R/2P
7.05
8.61
2
AC
Vertical
Right
J035530013030
UTV-30/R/2P
9.2
11.3
2
AC
Vertical
Right
J035530013040
UTV-40/R/2P
10.6
12.94
2
AC
Vertical
Right
J035530013050
UTV-50/R/2P
13.1
16.99
2
AC
Vertical
Right
J035530014110
UTV-10/L/4P
3.6
4.18
4
AC
Vertical
Left
J035530014120
UTV-20/L/4P
7.00
7.01
4
AC
Vertical
Left
J035530014130
UTV-30/L/4P
9.01
9.16
4
AC
Vertical
Left
J035530014140
UTV-40/L/4P
9.57
10.60
4
AC
Vertical
Left
J035530014150
UTV-50/L/4P
13.63
12.65
4
AC
Vertical
Left
J035530015010
UTV-10/R/4P
3.6
4.18
4
AC
Vertical
Right
J035530015020
UTV-20/R/4P
7.00
7.01
4
AC
Vertical
Right
J035530015030
UTV-30/R/4P
9.01
9.16
4
AC
Vertical
Right
J035530015040
UTV-40/R/4P
9.57
10.60
4
AC
Vertical
Right
J035530015050
UTV-50/R/4P
13.63
12.65
4
AC
Vertical
Right
J035530022010
UTC-10/L/2P
3.83
5.02
2
AC
Horizontal
Left
J035530022020
UTC-20/L/2P
7.05
8.61
2
AC
Horizontal
Left
J035530022030
UTC-30/L/2P
9.20
11.33
2
AC
Horizontal
Left
J035530022040
UTC-40/L/2P
10.60
12.94
2
AC
Horizontal
Left
J035530022050
UTC-50/L/2P
13.10
16.99
2
AC
Horizontal
Left
J035530023010
UTC-10/R/2P
3.83
5.02
2
AC
Horizontal
Right
J035530023020
UTC-20/R/2P
7.05
8.61
2
AC
Horizontal
Right
J035530023030
UTC-30/R/2P
9.20
11.33
2
AC
Horizontal
Right
J035530023040
UTC-40/R/2P
10.60
12.94
2
AC
Horizontal
Right
J035530023050
UTC-50/R/2P
13.10
16.99
2
AC
Horizontal
Right
J035530032010
UTC-10/L/4P
3.60
4.18
4
AC
Horizontal
Left
J035530032020
UTC-20/L/4P
7
7.01
4
AC
Horizontal
Left
J035530032030
UTC-30/L/4P
9.01
9.16
4
AC
Horizontal
Left
J035530032040
UTC-40/L/4P
9.57
10.60
4
AC
Horizontal
Left
J035530032050
UTC-50/L/4P
13.63
12.65
4
AC
Horizontal
Left
J035530033010
UTC-10/R/4P
3.60
4.18
4
AC
Horizontal
Right
J035530033020
UTC-20/R/4P
7
7.01
4
AC
Horizontal
Right
J035530033030
UTC-30/R/4P
9.01
9.16
4
AC
Horizontal
Right
J035530033040
UTC-40/R/4P
9.57
10.60
4
AC
Horizontal
Right
J035530033050
UTC-50/R/4P
13.63
12.65
4
AC
Horizontal
Right
*According to Eurovent at highest speed 0Pa
Air performance data
Q [m³/h]
75Pa
100Pa
150Pa
200Pa
250Pa
300Pa
400Pa
500Pa
600Pa
750Pa
1000Pa
HF R125 17D
375
300
150
-
-
-
-
-
-
-
-
HF R140 17D
550
500
400
200
-
-
-
-
-
-
-
HF R160 17D
-
800
700
600
300
-
-
-
-
-
-
HF R180 17D
-
-
1050
950
700
600
-
-
-
-
-
HF R200 17D
-
-
-
1450
1260
1080
600
-
-
-
-
HF R250 17D
-
-
-
-
3100
2880
2600
2160
1440
-
-
HF R280 17D
-
-
-
-
-
4400
4000
3600
3240
2160
-
HF R315 15D
-
-
-
-
-
-
3960
3600
3240
2160
-
HF R355 15D
-
-
-
-
-
-
-
5760
5400
4500
2520
HF R400 15D
-
-
-
-
-
-
-
-
7200
6840
5760
HF R450 15D
-
-
-
-
-
7200
6840
5760
4800
-
-
HF R500 15D
-
-
-
-
-
-
10440
9720
8640
6480
-
Attention
The given pressure is the total pressure.
Selection curves
Selection curves
Technical data
U [V]
P [kW]
I [A]
SCF
Tm [°C]
n [rpm]
Lpa @ 1m [dB(A)]
Lpa 5 = Lpa 6
Lpa 2
HF R125 17D
3x400
0.12
0.52
FIS-4420E-0.75-B
60
1450
53
41
HF R140 17D
3x400
0.12
0.52
FIS-4420E-0.75-B
60
1450
56
44
HF R160 17D
3x400
0.25
0.82
FIS-4420E-0.75-B
60
1450
60
48
HF R180 17D
3x400
0.25
0.82
FIS-4420E-0.75-B
60
1450
64
52
HF R200 17D
3x400
0.25
0.82
FIS-4420E-0.75-B
60
1450
67
55
HF R250 17D
3x400
0.55
1.60
FIS-4420E-0.75-B
60
1450
74
62
HF R280 17D
3x400
1.1
2.70
FIS-4420E-1.5-B
60
1450
77
66
HF R315 15D
3x400
1.1
2.70
FIS-4420E-1.5-B
60
1450
71
62
HF R355 15D
3x400
1.5
3.3
FIS-4420E-1.5-B
60
1450
75
66
HF R400 15D
3x400
3
6.33
FIS-4420E-4.0-B
60
1450
78
69
HF R450 15D
3x400
1.5
3.75
FIS-4420E-1.5-B
60
950
69
60
HF R500 15D
3x400
2.2
5.29
FIS-4420E-2.2-B
60
950
71
64
SCF = Speed controller
Tm = Maximum air temperature
Lpa 2 = Sound pressure level measured at 1 m distance with ducted inlet and outlet
Lpa 5 = Lpa 6 = Sound pressure level measured at 1 m distance in free field
Sound pressure level Lpa measured according to DIN 45635
Attention
At the orientation drawing, the motor is directed towards you.