The control valves ensure that only polluted and/or moist air is discharged, where and when required and in the right amount. The control valves are used as standard with the
Duco Comfort Plus &
Duco Tronic Plus systems.
- All 'dry rooms', such as the living room/open kitchen or the bedrooms, can be fitted with a CO2-controlled valve (DC-VAV CO2 75 and DC-VAV CO2 30): This constantly monitors the indoor climate and ensures for the polluted air (at a ppm> 800 ppm) to be extracted in the relevant room and only there
- The 'wet rooms', such as the bathroom, can be equipped with a controlled valve (DC-VAV RH 50): As soon as, for example, a shower is carried out, the moisture sensor on the valve automatically ensures that the moist air is extracted in the bathroom. until the condition is normalized again
- In addition, there is also a possibility to provide a sensorless valve (DC-VAV SC 25) for efficient drainage in, for example, the toilet: This valve can also be adjusted to any flow
- For the toilet, an extremely sensitive CO2 valve DC-VAV CO2 25 can optionally be provided, which already responds to a change of 5 ppm.
Wireless communication (via RF protocol) or wired communication (via Duco protocol) with other control components in the Duco network
- Measuring area:
- CO2 and temperature
- Relative humidity and temperature
- Measuring range: 400-2000 ppm or 0-100% RH
- Installation: in the DC-BOX FOCUS
- Placement:
- DC-VAV CO2 75 and DC-VAV CO2 30: Connected to the drain for the living room/open kitchen and bedroom(s)
- DC-VAV CO2 25: Following the drain for the toilet
- DC-VAV RH 50: Following the drain for the bathroom or laundry room
- DC-VAV SC 25: Valve without integrated sensor that can fulfill several functions, can be used in combination with DC-SEN room sensors, DC-CV control switch, DC-SC switch contact
- The standard flow rate of the control valves can be changed manually during or after installation via the display menu or via the Duco Ventilation App
- NOTE: For optimum system operation, all zones must be provided with a separate air duct network
DC-VAV CO2 75
Explanation:
DC = Duco brand
VAV = control valve
CO2 = measurement of CO2 content
75 = flow rate 75 m³ / h (adjustable)
Technical data
|
|
Width x height x depth | 141 x 167 x 46,5 mm | Weight | 220 g | Material | PP | Color | White | Sensors | Temperature (only CO2 control valve & RH control valve) CO2 (only CO2 control valve) Relative humidity (RH control valve only) | Communication | Wired | Power | 12 VDC (powered by the DucoBox) | Peak power | 2,04 W | Standby power | 0,24 W | RH range | 0-100 % RH | CO2 range | 300 - 2000 ppm | CO2 accuracy | DC-VAV CO2 25: 5 ppm +/- 5% Other types: 40 ppm +/- 5% | Polarity protection | Graetz bridge |
|