RENOVENT SKY • HRU system D ≤ 300 m³/h

Horizontal high efficiency heat recovery unit with counterflow heat exchanger. The range includes 3 sizes and 3 types for flow rates from 50 to 300 m³/h.

Brand

  • Brink

Accessories

  • wallmounted control, DCREN AC
  • 4-position switch with filter indication, type CVREN 4
  • Remote control (4 positions) with receiver, type RFREN
  • Stench trap, type SIP 32
  • Replacement filters, type FSREN SKY
  • Enthalpy changer, type WTW-H
  • Electric pre-heater, type CVR-VS (Sky 300)
  • Electric post-heater, type CVR-NS (plus version)
  • Humidity sensor, type HRT REN
  • CO2 sensor, type CO2 REN E-BUS

Technical data

 Q [m³/h]P [W]Lwa [dB(A)]
Lwa2Lwa5Lwa6
SKY 150V145 @ 10Pa19.0272741
V275 @ 25Pa27.0333450
V3105 @ 50Pa38.0384057
Vmax150 @ 100Pa72.0454764
SKY 200V175 @ 25 Pa17.03418.635.4
V2100 @ 50 Pa27.039.557.841.8
V3150 @ 100 Pa57.047.965.749.2
Vmax200 @ 100 Pa125.051.770.452.9
SKY 300V1100 @ 17Pa14.7293243
V2150 @ 67Pa27.5404353
V3225 @ 84Pa63.3464960
Vmax300 @ 150Pa133.2535569

Lwa2 = Sound power level enviromment
Lwa 5 = Sound power level @inlet
Lwa 6 = Sound power level @outlet

Energy efficiency class

ModelSensorsClock / sensor
SKY 150AA
SKY 300A+A

1: to the house 2: to outside 3: from the house

4: from outside 5: electrical connection 6: condensate drain

Dimensions

 

L [mm]

B [mm]

H [mm]

ø [mm]

[kg]

SKY 150

1000

660

198

125

24,5

SKY 200100066019816024,5

SKY 300

1185

644

310

150/160

37

Technical Data

 

Qv[m3/h]

P[W]

Lwa [dB(A)]

Lwa2

Lwa5

Lwa6

V1

100@26Pa

16.3

29

43

32

V2

150@38Pa

28

37

51

41

V3

225@84Pa

63.3

46

60

49

Vmax

300@150Pa

133.2

53

69

55

Note

Lwa2 = Sound power level enviromment

Lwa5= Sound power level @ inlet

Lwa6 = Sound power level @outlet