This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Heat recovery units with rotor heat exchanger for recuperation of humidity and electrical or water post-heating. The unit is available in different versions, 700 m³/h until 5500 m³/h with vertical outlets in left or right execution or with horizontal outlets. The unit has been tested according to NBN EN308.
Brand
R-COVERY by SALDA
Application
Ventilation for both residential and non-residential applications
For indoor mounting in a frost protected area
Outside mounting only
possible for horizontal versions (from model 700Hand on) with a roof (with electrical resistance to be built into the control box)
Composition
Housing in prelacquered steel plate RAL9016 (model 700) and RAL7040 (other models)
50 mm insulation
Round or rectangular connections depending on the model
2 motorised dampers included for horizontal model 2500 and higher
Electrical or warm water post-heating (external warm water battery not included)
Automatic bypass
Standard Modbus communication
Possibility of regulation by constant pressure or regulation by CO2 (sensors not included)
Filter detection with pressure switch
The remote control is not included
Fan
Directly driven EC direct current fan with backward inclined blades
Can be regulated 20-100%
Exchanger
Rotor heat exchanger on/off with high efficiency up to 80%
Version RHX: rotor with variable speed
Filter
HRS-RE / HRS-RW is equipped with two panelfilters M5 - ISO 16890 ePM10 55% / F7 - ISO 16890 ePM1 70% (exhaust/supply)
Versions
Vertical execution:
Type HRS-REV xxx L: vertical unit, left execution, electrical battery
Type HRS-REV xxx R:vertical unit, right execution, electrical battery
Type HRS-RWV xxx L: vertical unit, left execution, warm water battery
(external battery not included)
Type HRS-RWV xxx R:vertical unit, right execution, warm water battery (external battery not included)
Horizontal execution:
Type HRS-REH xxx: horizontal unit, electrical battery
Type HRS-RWH xxx: horizontal unit, warm water battery (external battery not included)
Mounting
HRS-R V 3500 will be delivered in 1 part
HRS-R H 3500 can be delivered in 3 parts, on demand
Accessories
Airtight control valve AKH
Manual control with weekly timer, type MC-HRS
Air outlet, type UT (for models up to 1900 m³/h)
Connection piece, type MDV (for models up to 1900 m³/h)