Flat heat recovery units with counterflow heat exchanger with or without integrated electrical post-heating. The unit is available in different versions until approx. 2.000 m³/h with horizontal outlets, in left or right execution. The unit is tested according to NBN EN308.


AmberAir Compact RIS-P is the successor to the HRS-F range.

Brand

  • R-COVERY by SALDA

Application

  • Ventilation for both residential and non-residential applications
  • For indoor mounting in a frost protected area

Composition

  • Housing in prelacquered steel plate RAL7040
  • 50mm rock wool insulation, fire class A1
  • Rectangular duct connections
  • Panel filters M5 - ISO 16890 ePM10 55% / F7 - ISO 16890 ePM1 65% (exhaust/supply)
  • Filter detection with pressure switch
  • Condensation tray with drain
  • Automatic bypass (100%)
  • With or without built-in electrical post-heater (duct battery available as an option)
  • Modbus communication included as standard
  • Possibility of regulation by constant pressure or CO2 (sensors not included)
  • The remote control is not included
  • MCB Light regulation

Fan

  • Directly driven EC direct current fan with backward inclined blades
  • Can be regulated 20-100%

Exchanger

  • High efficiency counterflow heat exchanger in aluminium
  • Heat exchanger certified according Eurovent EN 13141-7

Filter

  • The AmberAir Compact RIS-P unit is equipped with two filters
  • Panel filters M5 - ISO 16890 ePM10 55% / F7 - ISO 16890 ePM1 65% (exhaust/supply)

Regulation & functions

  • MCB regulation
    • Type RIS-P....E: can additionally control an external duct battery (cooling)
    • Type RIS-P....W: can control two external batteries (cooling and heating)

Versions

  • Type RIS-P xxxx WL: ceiling unit, without battery, left execution
  • Type RIS-P xxxx WR: ceiling unit, without battery, right execution
  • Type RIS-P xxxx EL: ceiling unit, with integrated electrical post heater, left execution
  • Type RIS-P xxxx ER: ceiling unit, with integrated electrical post heater, right execution


Versions

Certification

  • The unit is tested according to NBN EN 308: www.epbd.be
  • Getest volgens EUROVENT classificaties volgens EN13053
    • Mechanische sterkte: D1
    • Luchtdichtheidsklasse: L2/L1 (+700Pa/-400Pa)
    • Thermische overdrachtsklasse: T3
    • Koudebrugfactor: TB2
    • Filterlekkage: F9

Accessories

  • Touchscreen controller, type TS-AIR
  • Airtight control valve, type RM-RBS
  • Connection piece, type MS-RBS
  • CO2 transmitter, type DOX/E or WOX/E(-D)
  • Replacement filters, type FS-RIS

Order example

RIS-PE 1900 L

Explanation

RIS-P = type of heat recovery unit

E = with integrated electrical post-heating

1900 = size

L = left execution

Technical data

   RIS-P 1200 ERIS-P 1200 WRIS-P 1900 ERIS-P 1900 W
Main power supply [50Hz/VAC]1 x 2301 x 2301 x 2301 x 230
Heating batteryAbsorbed power[kW]3-3-
EC FansSupply voltage[50Hz/VAC]1 x 2301 x 2301 x 2301 x 230
Extract fanPower/current[kW/A]0,33/1,550,33/1,550,78/4,00,78/4,0
Extract fanFan speed[rpm]3350335037303730
Supply fanPower/current[kW/A]0,33/1,550,33/1,550,78/4,00,78/4,0
Supply fanFan speed[rpm]3350335037303730
Max. electrical power/current [kW/A]3,77/16,630,77/3,584,67/21,51,65/8,4
Working temperature between -23°C and +40°C

Dimensions

 Dimensions casing*Duct connectionsWeight
L [mm]W [mm]H [mm]D [mm]G [mm][kg]
RIS-P 120015501486393500250160
RIS-P 190017501956400700300250
*Dimensional drawing: see "Downloads"