PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

Flatpower • Ceiling mounted heat recovery units ≤ 2200 m³/h (counterflow)

  • Non residential
  • Counterflow
  • R-COVERY by ZEHNDER CALADAIR
  • Qv ≤ 2200 m³/h
  • Horizontal

Flat heat recovery unit with high efficiency > 90%. The range includes 5 sizes and 4 types for flow rates from 100 to 2200 m³/h.

The Flatpower Premium is a self-regulating ceiling unit with an extensive control module and is equipped with either an electric battery or a water or DX change-over battery. Each Flatpower Premium model comes standard with 2 adjustable flow rates.

The unit is only intended for an indoor installation.


The Flatpower is available in 4 versions:


  • FLATPOWER FIRST (Basic unit with 2 filters, 2 fans and counterflow)
  • FLATPOWER SMART (First with electric preheating battery)
  • FLATPOWER PREMIUM (First with electric post-heating battery OR water/DX change-over battery)
  • FLATPOWER INFINITE (Premium unit with electric preheating battery)


The Flatpower has a EUROVENT and VDI certificate!

The Flatpower will be EPB approved according to NBN EN 308.

Brand

  • R-COVERY by ZEHNDER CALADAIR

Application

  • Self-regulated ventilation and high efficiency heat recovery for non-residential and industrial installations
  • Air filtration, temperature control
  • Compact monoblock ventilation unit, with plug & play energy-saving regulation (EN 15232)

Composition

  • Double skinned panels with high-density mineral wool insulation 25 mm (M0), fire class A2-S1
  • Outer layer: prelacquered steel plate in light grey (RAL 7035) with protective foil
  • Inner layer: galvanized steel plate 10/10
  • Appropriate for indoor installation, ceiling mounting
  • Patented mounting frame for easy ceiling mounting
  • Access from underneath
  • Round connections with lip sealing for all models
  • Integrated condensate tray with 2% slope for easy installation and drain ½”
  • Built-in 100% Bypass, motorised and auto-regulating
  • Built-in regulation with display
  • Integrated FREE-COOLING and NIGHT-COOLING function
  • Built-in temperature sensors (4)
  • Built-in clock for operation between two flow rates
  • Built-in week clock with public holidays
  • Safety switch
  • Pressure switch on inlet filter F7
  • Pressure switch on each fan
  • Fire safety function that allows control of the supply and extraction fans.
  • Standard Modbus or Bacnet available
  • Only available in right version (see configuration)

Fan

  • Direct driven EC motor with electronic commutation (EC) with high efficiency, thermal protection and integrated speed control
  • The EC technology ensures limited energy consumption by managing and controlling the operating point (regulation from 10 to 100%)
  • Low noise level for a better acoustic comfort

Exchanger

  • High-efficiency counterflow heat exchanger made of seawater-resistant aluminum
  • Efficiency >90% (EN308)
  • Frost protection through bypass regulation

Filter

  • Filters are placed directly in front of the components for optimal protection
  • Mounted on sliding rails with lip sealing to ensure efficient air tightness
  • Flatpower basic configuration with a F7 - ISO 16890 ePM1 55% - (inlet air) filter and a M5 - ISO 16890 ePM10 50% - (exhaust air) filter, thickness 48mm
  • F7 high efficiency filter: 10x higher filtration surface than a gravimetric filter and 2,5x longer life span

Versions

  • Flatpower First: ventilation group without integrated battery
  • Flatpower Smart: ventilation group equipped with an integrated electric preheating resistance
  • Flatpower Premium BE: ventilation group equipped with an integrated electric post-heating resistance
  • Flatpower Premium CO: ventilation group equipped with an integrated water battery as a change-over coil (cooling OR heating)
  • Flatpower Premium DX: ventilation group equipped with an integrated DX battery as a change-over coil (cooling OR heating)
  • Flatpower Infinite BE: ventilation group equipped with an integrated electric preheating resistance and an integrated electric post-heating resistance
  • Flatpower Infinite CO: ventilation group equipped with an integrated electric preheating resistance and an integrated water battery as a change-over coil (cooling OR heating)
  • Flatpower Infinite DX: ventilation group equipped with an integrated electric preheating resistance and an integrated DX battery as a change-over coil (cooling OR heating)

Options

  • ECO®: Adjusting the speed of the fans by entering 2 air flow rates (high – low flow) in the regulation
  • MAC2®EC: DTwo constant flow rates for each fan
  • LOBBY®: Constant pressure for each fan for use with e.g. VAV boxes
  • DIVA®: Proportional modulating flow rate (between a set min. and max. flow rate) of each fan according to a built-in CO2 measurement.

Certification

  • The device is tested according to NBN EN 308: www.epbd.be
  • Efficiency of the heat exchanger of more than 90% (EN308), in accordance with RT2012 and ErP 2009/125/EC directives
  • EUROVENT classifications according to EN1886 and EN13053
  • Standard construction with double skinned panels of 25mm
  • Mechanical strength class: D2
  • Air tightness class: L1
  • Conductivity: T3
  • Thermal bridge factor: TB3
  • Filter leakage class: F9
  • Insulation: high density 25mm mineral wool, fire class A2-S1 (M0)

Accessories

  • Airtight control valves, type AKH
  • Replacement filters FS-FLATPOWER
  • Controllers for Flatpower:
    • Easy 5.0 controller mounted on the unit as standard
      • Master touch screen controller
    • EDT2 remote controller available as an option
      • Touch screen controller for end user

Other available products

  • Neotime

Text for tender

Kopiëren
See downloads

Order example

Flatpower 600 Premium BE MAC2

Explanation

Flatpower = type of heat recovery unit

600 = size (600-900-1300-1800-2500)

Premium = Premium version

BE = with electrical battery

MAC2 = MAC2 regulation

Electrical data

 PT  FIRST/PREMIUM CO/DXRINFINITE CO/DXR
SMART
PREMIUM BEINFINITE BE
[W][°C / °C][V/Ph/Hz][A][V/Ph/Hz][A][V/Ph/Hz][A][V/Ph/Hz][A]
6002 x 169-20 / 60IP54/BPTI230/1/502,8230/1/508,2230/1/508,2230/1/5013,7
9002 x 220-20 / 60IP44/BPTI230/1/503,4230/1/5014,3230/1/5011230/1/5021,9
13002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5023,6230/1/5019,5230/1/5034,7
18002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5024,9230/1/5024,9400/3+N/5015,1
25002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5031,4230/1/5031,4400/3+N/5019,5

Battery

For more info, see downloads

Horizontal configurations - side by side flow - top view

The Flatpower is only available in a right version, viewed from the top of the device, following the direction of the air flow. The access doors are located at the bottom of the unit.

Dimensions

  600900130018002500
Ø[mm]250315355400400
A[mm]20052245235524352435
A1[mm]610640885885885
A2[mm]610640595595595
B[mm]8551040129512951815
C[mm]390485485565565
E[mm]390495600600900
E1[mm]290325405405545
E2[mm]205255255290290
F[mm]13551595144515251525
F1[mm]245245520520520
F2[mm]245245230230230
G[mm]8075325325330
G1[mm]155155430430430
J[mm]110110110110110
J1[mm]170250250330330
J2[mm]320415420495500
K[mm]12651420133014151415
K1[mm]310405405485485
L1[mm]365550---
L2[mm]--348348510
L3[mm]--348348510
M1[mm]172172172172272
M2[mm]95959595194
ØT1''1/2''1/2''1/2''1/2''1/2''
ØT2 out''1/2''1/2''5/8''5/8''3/4''
ØT3 in''3/8''3/8''1/2''1/2''5/8''
FIRST / SMART[kg]172240297321418
PREMIUM BE[kg]174244300323423
PREMIUM CO/DXR[kg]176247306327431
INFINITE BE[kg]176245300329425
INFINITE CO/DXR[kg]178248308333433
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be