This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Flat heat recovery unit with high efficiency > 90%.
The range includes 5 sizes and 4 types for flow rates from 100 to 2200 m³/h.
The Flatpower Premium is a self-regulating ceiling
unit with an extensive control module and is equipped with either an electric
battery or a water or DX change-over battery. Each Flatpower Premium model
comes standard with 2 adjustable flow rates.
The unit is only intended for an indoor installation.
The Flatpower is available in 4 versions:
FLATPOWER FIRST (Basic unit with 2 filters, 2 fans and
counterflow)
FLATPOWER SMART (First with electric preheating
battery)
FLATPOWER PREMIUM (First with electric post-heating
battery OR water/DX change-over battery)
FLATPOWER INFINITE (Premium unit with electric preheating
battery)
The Flatpower has a EUROVENT and VDI certificate!
The Flatpower will be EPB approved according to NBN EN 308.
Brand
R-COVERY by ZEHNDER CALADAIR
Application
Self-regulated ventilation and high efficiency heat recovery for non-residential and industrial installations
Air filtration, temperature control
Compact monoblock ventilation unit, with plug & play energy-saving regulation (EN 15232)
Composition
Double skinned panels with high-density mineral wool insulation 25 mm (M0), fire class A2-S1
Outer layer: prelacquered steel plate in light grey (RAL 7035) with protective foil
Inner layer: galvanized steel plate 10/10
Appropriate for indoor installation, ceiling mounting
Patented mounting frame for easy ceiling mounting
Access from underneath
Round connections with lip sealing for all models
Integrated condensate tray with 2% slope for easy installation and drain ½”
Built-in 100% Bypass, motorised and auto-regulating
Built-in regulation with display
Integrated FREE-COOLING and NIGHT-COOLING function
Built-in temperature sensors (4)
Built-in clock for operation between two flow rates
Built-in week clock with public holidays
Safety switch
Pressure switch on inlet filter F7
Pressure switch on each fan
Fire safety function that allows control of the supply and extraction fans.
Standard Modbus or Bacnet available
Only available in right version (see configuration)
Fan
Direct driven EC motor with electronic commutation (EC) with high efficiency, thermal protection and integrated speed control
The EC technology ensures limited energy consumption by managing and controlling the operating point (regulation from 10 to 100%)
Low noise level for a better acoustic comfort
Exchanger
High-efficiency counterflow heat exchanger made of seawater-resistant aluminum
Efficiency >90% (EN308)
Frost protection through bypass regulation
Filter
Filters are placed directly in front of the components for optimal protection
Mounted on sliding rails with lip sealing to ensure efficient air tightness
Flatpower basic configuration with a F7 - ISO 16890 ePM1 55% - (inlet air) filter and a M5 - ISO 16890 ePM10 50% - (exhaust air)filter, thickness 48mm
F7 high efficiency filter: 10x higher filtration surface than a gravimetric filter and 2,5x longer life span
Versions
Flatpower First: ventilation group without integrated battery
Flatpower Smart: ventilation group equipped with an integrated electric preheating resistance
Flatpower Premium BE: ventilation group equipped with an integrated electric post-heating resistance
Flatpower Premium CO: ventilation group equipped with an integrated water battery as a change-over coil (cooling OR heating)
Flatpower Premium DX: ventilation group equipped with an integrated DX battery as a change-over coil (cooling OR heating)
Flatpower Infinite BE: ventilation group equipped with an integrated electric preheating resistance and an integrated electric post-heating resistance
Flatpower Infinite CO: ventilation group equipped with an integrated electric preheating resistance and an integrated water battery as a change-over coil (cooling OR heating)
Flatpower Infinite DX: ventilation group equipped with an integrated electric preheating resistance and an integrated DX battery as a change-over coil (cooling OR heating)
Options
ECO®: Adjusting the speed of the fans by entering 2 air flow rates (high – low flow) in the regulation
MAC2®EC:DTwo constant flow rates for each fan
LOBBY®: Constant pressure for each fan for use with e.g. VAV boxes
DIVA®: Proportional modulating flow rate (between a set min. and max. flow rate) of each fan according to a built-in CO2 measurement.
Certification
The device is tested according to NBN EN 308: www.epbd.be
Efficiency of the heat exchanger of more than 90% (EN308), in accordance with RT2012 and ErP 2009/125/EC directives
EUROVENT classifications according to EN1886 and EN13053
Standard construction with double skinned panels of 25mm
Mechanical strength class: D2
Air tightness class: L1
Conductivity: T3
Thermal bridge factor: TB3
Filter leakage class: F9
Insulation: high density 25mm mineral wool, fire class A2-S1 (M0)
Accessories
Airtight control valves, type AKH
Replacement filters FS-FLATPOWER
Controllers for Flatpower:
Easy 5.0 controller
mounted on the unit as standard
Master touch screen controller
EDT2 remote
controller available as an option
Touch screen controller for end user
Other available products
Neotime
Text for tender
See downloads
See downloads
Order example
Flatpower 600 Premium BE MAC2
Explanation
Flatpower = type of heat recovery unit
600 = size (600-900-1300-1800-2500)
Premium = Premium version
BE = with electrical battery
MAC2 = MAC2 regulation
Articles
Artikelselectie-assistent
Type
Diameter [mm]
Type
Oriëntatie
Spanning [V]
Artikelnummer
Type
Diameter [mm]
Type
Oriëntatie
Spanning [V]
E-shop
I050111125440
HF R 125-17D 400V 1400 rpm GR360
125
17D
GR360**
400
I050111125441
HF R 125-17D 400V 1400 rpm GL360
125
17D
GL360**
400
I050111125442
HF R 125-17D 400V 1400 rpm GR090
125
17D
GR090**
400
I050111125443
HF R 125-17D 400V 1400 rpm GL090
125
17D
GL090**
400
I050111140440
HF R 140-17D 400V 1400 rpm GR360
140
17D
GR360**
400
I050111140441
HF R 140-17D 400V 1400 rpm GL360
140
17D
GL360**
400
I050111140442
HF R 140-17D 400V 1400 rpm GR090
140
17D
GR090**
400
I050111140443
HF R 140-17D 400V 1400 rpm GL090
140
17D
GL090**
400
I050111160440
HF R 160-17D 400V 1400 rpm GR360
160
17D
GR360**
400
I050111160441
HF R 160-17D 400V 1400 rpm GL360
160
17D
GL360**
400
I050111160442
HF R 160-17D 400V 1400 rpm GR090
160
17D
GR090**
400
I050111160443
HF R 160-17D 400V 1400 rpm GL090
160
17D
GL090**
400
I050111180440
HF R 180-17D 400V 1400 rpm GR360
180
17D
GR360**
400
I050111180441
HF R 180-17D 400V 1400 rpm GL360
180
17D
GL360**
400
I050111180442
HF R 180-17D 400V 1400 rpm GR090
180
17D
GR090**
400
I050111180443
HF R 180-17D 400V 1400 rpm GL090
180
17D
GL090**
400
I050111200440
HF R 200-17D 400V 1400 rpm GR360
200
17D
GR360**
400
I050111200441
HF R 200-17D 400V 1400 rpm GL360
200
17D
GL360**
400
I050111200442
HF R 200-17D 400V 1400 rpm GR090
200
17D
GR090**
400
I050111200443
HF R 200-17D 400V 1400 rpm GL090
200
17D
GL090**
400
I050111250440
HF R 250-17D 400V 1400 rpm GR360
250
17D
GR360**
400
I050111250441
HF R 250-17D 400V 1400 rpm GL360
250
17D
GL360**
400
I050111250442
HF R 250-17D 400V 1400 rpm GR090
250
17D
GR090**
400
I050111250443
HF R 250-17D 400V 1400 rpm GL090
250
17D
GL090**
400
I050111280440
HF R 280-17D 400V 1400 rpm GR360
280
17D
GR360**
400
I050111280441
HF R 280-17D 400V 1400 rpm GL360
280
17D
GL360**
400
I050111280442
HF R 280-17D 400V 1400 rpm GR090
280
17D
GR090**
400
I050111280443
HF R 280-17D 400V 1400 rpm GL090
280
17D
GL090**
400
I050111315440
HF R 315-15D 400V 1400 rpm GR360
315
15D
GR360**
400
I050111315441
HF R 315-15D 400V 1400 rpm GL360
315
15D
GL360**
400
I050111315442
HF R 315-15D 400V 1400 rpm GR090
315
15D
GR090**
400
I050111315443
HF R 315-15D 400V 1400 rpm GL090
315
15D
GL090**
400
I050111355440
HF R 355-15D 400V 1400 rpm GR360
355
15D
GR360**
400
I050111355441
HF R 355-15D 400V 1400 rpm GL360
355
15D
GL360**
400
I050111355442
HF R 355-15D 400V 1400 rpm GR090
355
15D
GR090**
400
I050111355443
HF R 355-15D 400V 1400 rpm GL090
355
15D
GL090**
400
I050111400440
HF R 400-15D 400V 1400 rpm GR360
400
15D
GR360**
400
I050111400441
HF R 400-15D 400V 1400 rpm GL360
400
15D
GL360**
400
I050111400442
HF R 400-15D 400V 1400 rpm GR090
400
15D
GR090**
400
I050111400443
HF R 400-15D 400V 1400 rpm GL090
400
15D
GL090**
400
I050111450440
HF R 450-15D 400V 900 rpm GR360
450
15D
GR360**
400
I050111450441
HF R 450-15D 400V 900 rpm GL360
450
15D
GL360**
400
I050111450442
HF R 450-15D 400V 900 rpm GR090
450
15D
GR090**
400
I050111450443
HF R 450-15D 400V 900 rpm GL090
450
15D
GL090**
400
I050111500440
HF R 500-15D 400V 900 rpm GR360
500
15D
GR360**
400
I050111500441
HF R 500-15D 400V 900 rpm GL360
500
15D
GL360**
400
I050111500442
HF R 500-15D 400V 900 rpm GR090
500
15D
GR090**
400
I050111500443
HF R 500-15D 400V 900 rpm GL090
500
15D
GL090**
400
** Oriëntatie te bepalen aan de hand van onderstaande technische tekening
Electrical data
P
T
FIRST/PREMIUM CO/DXR
INFINITE CO/DXR
SMART
PREMIUM BE
INFINITE BE
[W]
[°C / °C]
[V/Ph/Hz]
[A]
[V/Ph/Hz]
[A]
[V/Ph/Hz]
[A]
[V/Ph/Hz]
[A]
600
2 x 169
-20 / 60
IP54/B
PTI
230/1/50
2,8
230/1/50
8,2
230/1/50
8,2
230/1/50
13,7
900
2 x 220
-20 / 60
IP44/B
PTI
230/1/50
3,4
230/1/50
14,3
230/1/50
11
230/1/50
21,9
1300
2 x 400
-20 / 40
IP44/F
PTI
230/1/50
8,6
230/1/50
23,6
230/1/50
19,5
230/1/50
34,7
1800
2 x 400
-20 / 40
IP44/F
PTI
230/1/50
8,6
230/1/50
24,9
230/1/50
24,9
400/3+N/50
15,1
2500
2 x 400
-20 / 40
IP44/F
PTI
230/1/50
8,6
230/1/50
31,4
230/1/50
31,4
400/3+N/50
19,5
Battery
For more info, see downloads
Horizontal configurations - side by side flow - top view
The Flatpower is only available in a right version, viewed from the top of the device, following the direction of the air flow. The access doors are located at the bottom of the unit.