PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

Flatpower • Ceiling mounted heat recovery units ≤ 2200 m³/h (counterflow)

  • Non residential
  • Counterflow
  • R-COVERY by ZEHNDER CALADAIR
  • Qv ≤ 2200 m³/h
  • Horizontal

Flat heat recovery unit with high efficiency > 90%. The range includes 5 sizes and 4 types for flow rates from 100 to 2200 m³/h.

The Flatpower Premium is a self-regulating ceiling unit with an extensive control module and is equipped with either an electric battery or a water or DX change-over battery. Each Flatpower Premium model comes standard with 2 adjustable flow rates.

The unit is only intended for an indoor installation.


The Flatpower is available in 4 versions:


  • FLATPOWER FIRST (Basic unit with 2 filters, 2 fans and counterflow)
  • FLATPOWER SMART (First with electric preheating battery)
  • FLATPOWER PREMIUM (First with electric post-heating battery OR water/DX change-over battery)
  • FLATPOWER INFINITE (Premium unit with electric preheating battery)


The Flatpower has a EUROVENT and VDI certificate!

The Flatpower will be EPB approved according to NBN EN 308.

Brand

  • R-COVERY by ZEHNDER CALADAIR

Application

  • Self-regulated ventilation and high efficiency heat recovery for non-residential and industrial installations
  • Air filtration, temperature control
  • Compact monoblock ventilation unit, with plug & play energy-saving regulation (EN 15232)

Composition

  • Double skinned panels with high-density mineral wool insulation 25 mm (M0), fire class A2-S1
  • Outer layer: prelacquered steel plate in light grey (RAL 7035) with protective foil
  • Inner layer: galvanized steel plate 10/10
  • Appropriate for indoor installation, ceiling mounting
  • Patented mounting frame for easy ceiling mounting
  • Access from underneath
  • Round connections with lip sealing for all models
  • Integrated condensate tray with 2% slope for easy installation and drain ½”
  • Built-in 100% Bypass, motorised and auto-regulating
  • Built-in regulation with display
  • Integrated FREE-COOLING and NIGHT-COOLING function
  • Built-in temperature sensors (4)
  • Built-in clock for operation between two flow rates
  • Built-in week clock with public holidays
  • Safety switch
  • Pressure switch on inlet filter F7
  • Pressure switch on each fan
  • Fire safety function that allows control of the supply and extraction fans.
  • Standard Modbus or Bacnet available
  • Only available in right version (see configuration)

Fan

  • Direct driven EC motor with electronic commutation (EC) with high efficiency, thermal protection and integrated speed control
  • The EC technology ensures limited energy consumption by managing and controlling the operating point (regulation from 10 to 100%)
  • Low noise level for a better acoustic comfort

Exchanger

  • High-efficiency counterflow heat exchanger made of seawater-resistant aluminum
  • Efficiency >90% (EN308)
  • Frost protection through bypass regulation

Filter

  • Filters are placed directly in front of the components for optimal protection
  • Mounted on sliding rails with lip sealing to ensure efficient air tightness
  • Flatpower basic configuration with a F7 - ISO 16890 ePM1 55% - (inlet air) filter and a M5 - ISO 16890 ePM10 50% - (exhaust air) filter, thickness 48mm
  • F7 high efficiency filter: 10x higher filtration surface than a gravimetric filter and 2,5x longer life span

Versions

  • Flatpower First: ventilation group without integrated battery
  • Flatpower Smart: ventilation group equipped with an integrated electric preheating resistance
  • Flatpower Premium BE: ventilation group equipped with an integrated electric post-heating resistance
  • Flatpower Premium CO: ventilation group equipped with an integrated water battery as a change-over coil (cooling OR heating)
  • Flatpower Premium DX: ventilation group equipped with an integrated DX battery as a change-over coil (cooling OR heating)
  • Flatpower Infinite BE: ventilation group equipped with an integrated electric preheating resistance and an integrated electric post-heating resistance
  • Flatpower Infinite CO: ventilation group equipped with an integrated electric preheating resistance and an integrated water battery as a change-over coil (cooling OR heating)
  • Flatpower Infinite DX: ventilation group equipped with an integrated electric preheating resistance and an integrated DX battery as a change-over coil (cooling OR heating)

Options

  • ECO®: Adjusting the speed of the fans by entering 2 air flow rates (high – low flow) in the regulation
  • MAC2®EC: DTwo constant flow rates for each fan
  • LOBBY®: Constant pressure for each fan for use with e.g. VAV boxes
  • DIVA®: Proportional modulating flow rate (between a set min. and max. flow rate) of each fan according to a built-in CO2 measurement.

Certification

  • The device is tested according to NBN EN 308: www.epbd.be
  • Efficiency of the heat exchanger of more than 90% (EN308), in accordance with RT2012 and ErP 2009/125/EC directives
  • EUROVENT classifications according to EN1886 and EN13053
  • Standard construction with double skinned panels of 25mm
  • Mechanical strength class: D2
  • Air tightness class: L1
  • Conductivity: T3
  • Thermal bridge factor: TB3
  • Filter leakage class: F9
  • Insulation: high density 25mm mineral wool, fire class A2-S1 (M0)

Accessories

  • Airtight control valves, type AKH
  • Replacement filters FS-FLATPOWER
  • Controllers for Flatpower:
    • Easy 5.0 controller mounted on the unit as standard
      • Master touch screen controller
    • EDT2 remote controller available as an option
      • Touch screen controller for end user

Other available products

  • Neotime

Text for tender

Copy
See downloads

Order example

Flatpower 600 Premium BE MAC2

Explanation

Flatpower = type of heat recovery unit

600 = size (600-900-1300-1800-2500)

Premium = Premium version

BE = with electrical battery

MAC2 = MAC2 regulation

Artikelen

Artikelselectie-assistent
Type batterij
Configuratie
Type
Grootte
Artikelnummer Type batterij Configuratie Type Grootte E-shop Wisselstukken
I100880000601 BC DIVA SILVERTOP 06 PRE BC DIVA 6
I100880000602 BC LOBBY SILVERTOP 06 PRE BC LOBBY 6
I100880000801 BC DIVA SILVERTOP 08 PRE BC DIVA 8
I100880000802 BC LOBBY SILVERTOP 08 PRE BC LOBBY 8
I100880001501 BC DIVA SILVERTOP 15 PRE BC DIVA 15
I100880001502 BC LOBBY SILVERTOP 15 PRE BC LOBBY 15
I100880001503 BC MAC2 SILVERTOP 15 PRE BC MAC2 15
I100880001504 BC QUATTR SILVERTOP 15 PRE BC QUATTR 15
I100880002301 BC DIVA SILVERTOP 23 PRE BC DIVA 23
I100880002302 BC LOBBY SILVERTOP 23 PRE BC LOBBY 23
I100880002303 BC MAC2 SILVERTOP 23 PRE BC MAC2 23
I100880002304 BC QUATTR SILVERTOP 23 PRE BC QUATTR 23
I100880003501 BC DIVA SILVERTOP 35 PRE BC DIVA 35
I100880003502 BC LOBBY SILVERTOP 35 PRE BC LOBBY 35
I100880003503 BC MAC2 SILVERTOP 35 PRE BC MAC2 35
I100880003504 BC QUATTR SILVERTOP 35 PRE BC QUATTR 35
I100880005201 BC DIVA SILVERTOP 52 PRE BC DIVA 52
I100880005202 BC LOBBY SILVERTOP 52 PRE BC LOBBY 52
I100880005203 BC MAC2 SILVERTOP 52 PRE BC MAC2 52
I100880005204 BC QUATTR SILVERTOP 52 PRE BC QUATTR 52
I100881000601 BE DIVA SILVERTOP 06 PRE BE DIVA 6
I100881000602 BE LOBBY SILVERTOP 06 PRE BE LOBBY 6
I100881000801 BE DIVA SILVERTOP 08 PRE BE DIVA 8
I100881000802 BE LOBBY SILVERTOP 08 PRE BE LOBBY 8
I100881001501 BE DIVA SILVERTOP 15 PRE BE DIVA 15
I100881001502 BE LOBBY SILVERTOP 15 PRE BE LOBBY 15
I100881001503 BE MAC2 SILVERTOP 15 PRE BE MAC2 15
I100881001504 BE QUATTR SILVERTOP 15 PRE BE QUATTR 15
I100881002301 BE DIVA SILVERTOP 23 PRE BE DIVA 23
I100881002302 BE LOBBY SILVERTOP 23 PRE BE LOBBY 23
I100881002303 BE MAC2 SILVERTOP 23 PRE BE MAC2 23
I100881002304 BE QUATTR SILVERTOP 23 PRE BE QUATTR 23
I100881003501 BE DIVA SILVERTOP 35 PRE BE DIVA 35
I100881003502 BE LOBBY SILVERTOP 35 PRE BE LOBBY 35
I100881003503 BE MAC2 SILVERTOP 35 PRE BE MAC2 35
I100881003504 BE QUATTR SILVERTOP 35 PRE BE QUATTR 35
I100881005201 BE DIVA SILVERTOP 52 PRE BE DIVA 52
I100881005202 BE LOBBY SILVERTOP 52 PRE BE LOBBY 52
I100881005203 BE MAC2 SILVERTOP 52 PRE BE MAC2 52
I100881005204 BE QUATTR SILVERTOP 52 PRE BE QUATTR 52

Electrical data

 PT  FIRST/PREMIUM CO/DXRINFINITE CO/DXR
SMART
PREMIUM BEINFINITE BE
[W][°C / °C][V/Ph/Hz][A][V/Ph/Hz][A][V/Ph/Hz][A][V/Ph/Hz][A]
6002 x 169-20 / 60IP54/BPTI230/1/502,8230/1/508,2230/1/508,2230/1/5013,7
9002 x 220-20 / 60IP44/BPTI230/1/503,4230/1/5014,3230/1/5011230/1/5021,9
13002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5023,6230/1/5019,5230/1/5034,7
18002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5024,9230/1/5024,9400/3+N/5015,1
25002 x 400-20 / 40IP44/FPTI230/1/508,6230/1/5031,4230/1/5031,4400/3+N/5019,5

Battery

For more info, see downloads

Horizontal configurations - side by side flow - top view

The Flatpower is only available in a right version, viewed from the top of the device, following the direction of the air flow. The access doors are located at the bottom of the unit.

Dimensions

  600900130018002500
Ø[mm]250315355400400
A[mm]20052245235524352435
A1[mm]610640885885885
A2[mm]610640595595595
B[mm]8551040129512951815
C[mm]390485485565565
E[mm]390495600600900
E1[mm]290325405405545
E2[mm]205255255290290
F[mm]13551595144515251525
F1[mm]245245520520520
F2[mm]245245230230230
G[mm]8075325325330
G1[mm]155155430430430
J[mm]110110110110110
J1[mm]170250250330330
J2[mm]320415420495500
K[mm]12651420133014151415
K1[mm]310405405485485
L1[mm]365550---
L2[mm]--348348510
L3[mm]--348348510
M1[mm]172172172172272
M2[mm]95959595194
ØT1''1/2''1/2''1/2''1/2''1/2''
ØT2 out''1/2''1/2''5/8''5/8''3/4''
ØT3 in''3/8''3/8''1/2''1/2''5/8''
FIRST / SMART[kg]172240297321418
PREMIUM BE[kg]174244300323423
PREMIUM CO/DXR[kg]176247306327431
INFINITE BE[kg]176245300329425
INFINITE CO/DXR[kg]178248308333433
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...