FIS(-C)-11-B • Frequency converters 1x230V

  • Frequency converter
  • 1x230V / 1x230V
  • 4.3 - 10.5A
  • IP20 / IP66

Frequency converter 1x230V

Application

  • The FIS(-C)-11 brings solutions to meet any demand for frequency conversion in a power range between 0.37 kW and 1.1 kW.

Composition

  • Single-phase input / single-phase output (1x230V / 1x230V)
  • Frequency input: 48 - 62 Hz
  • Frequency output: 0 - 500 Hz
  • Protection class:
    • IP20 type FIS
    • IP66 type FIS-C, equipped with potentiometer and 3-position switch
  • Maximum ambient temperature: 0...50°C; storage max. -40...+60°C
  • Equipped with control panel and terminal strip for external control
  • Serial communication Modbus RTU
  • EMC filter

Text for tender

Kopiëren
  • The frequency inverter will have: single-phase input/ signle-phase output (1x230V / 1x230V), small mechanical IP20 or IP66 housing, heavy industrial operation at ambient temperatures up to 50°C, no external fans to replace, simple mechanical and electrical installation, simple operation, powerful features and easy to use, fast setup, factory default settings for most applications, only fourteen basic parameters, motor current and rpm indication, 150 % overload for 60 sec (175 % for 2 sec), keypad control, integral RFI filter option, modbus RTU serial communication, PI control for feedback.
  • CAIROX type FIS(-C)-11

Order example

FIS-1320E-0.75-B

Explication
FIS-11 - frequency inverter type
20 - IP protection class
E - EMC filter
0.75 - motor power
B = basic version

Artikelen

Artikelselectie-assistent
Type batterij
Type
Grootte
Artikelnummer Type batterij Type Grootte E-shop
I100254010120 BC CB-BC 1000 L 1000
I100254010130 DX CB-DX 1000 L 1000
I100254010220 BC CB-BC 1000 R 1000
I100254010230 DX CB-DX 1000 R 1000
I100254015120 BC CB-BC 1500 L 1500
I100254015130 DX CB-DX 1500 L 1500
I100254015220 BC CB-BC 1500 R 1500
I100254015230 DX CB-DX 1500 R 1500
I100254020120 BC CB-BC 2000 L 2000
I100254020130 DX CB-DX 2000 L 2000
I100254020220 BC CB-BC 2000 R 2000
I100254020230 DX CB-DX 2000 R 2000
I100254030120 BC CB-BC 3000 L 3000
I100254030130 DX CB-DX 3000 L 3000
I100254030220 BC CB-BC 3000 R 3000
I100254030230 DX CB-DX 3000 R 3000

Notes

INPUTS
  • PE = earth connections
  • L1 L = single phase supply voltage 230 Vac– 50/60 Hz - line
  • L2 N = signle phase supply voltage 230 Vac– 50/60 Hz - neutral
  • Fuses = *fuses depending on nominal power
OUTPUTS
  • U = output to motor 230V
  • V = output to motor 230V
TERMINAL STRIP 1-11 (based on factory settings)
  • 1. connect a start/stop switch to terminals 1 and 2 close contact = start contact open = stop
  • 2. connect a 10 kOhm potentiometer to terminals 5, 6 and 7 to vary the speed from 35 to 50 Hz (60 Hz for HP drives)