PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

HTI PREMIUM+ • Inverter high temperature heat pump 70°C

The HTI air/water heat pump uses heat from nature and converts it into usable hot water. The construction of the unit makes it possible to heat water up to 70°C at negative outside temperatures without using a resistance. The unit guarantees good operation down to -20°C outside temperature. The natural refrigerant R290 (propane) has a GWP value of 3 and is therefore hundreds of times better than alternative refrigerants. The HTI is a single heating unit that uses a scroll compressor to ensure a good operation in part load and a low power consumption. Due to the special construction of the unit, the unit will have to defrost less often and the defrost cycle will be completed as efficiently as possible. The unit maintains its high COP values even at negative outside temperatures.

Brand

  • Auer - Intuis

Application

  • Production of domestic hot water
  • Floor heating
  • Fan coils
  • Radiators

Appropriate for:
  • Renovation of houses

Composition

Monoblock outdoor unit HTI70 6-8-11-14 kW including:

  • Communication bus cable 10 m long HTI/ Pilote (3-wired and already connected to the HTI) (do not connect in parallel with the power cable).
  • Flexible hose (Durite) 1 m long => rest in an insulated rigid pipe towards the indoor module (diameter depending on the distance between the two, see table below).
  • Ball valve with integrated filter to be mounted on the return connection.
  • Overpressure valve 2.5 bar to be mounted on the flow connection.


Indoor module Pilote PREMIUM+:

  • 1x primary + 1x secondary pump
  • Buffer tank/ hydraulic decoupling bottle 38 liters with air purge and drain valve
  • Extra hydraulic connection for bivalent operation with boiler
  • Adjustable backup resistance 0-6 kW
  • Pressure sensor
  • Flow meter
  • Electronic regulation
  • USB stick (included with manual)
  • Outdoor sensor for weather dependent control

Installation

  • When combining production of DHW with central heating water, an extra pump and a DHW S HRC70 sensor must be provided.
  • The addition of an anti-corrosion agent or a glycol/anti-corrosion mixture is mandatory.

Accessories

  • Room thermostat TH HRC70
  • Domestic hot water sensor DHW S HRC70
  • Additional secondary pump HRC PK Premium+
  • Regulation on 2nd circuit with lower water temperature THORIX
  • Clean existing heating systems first.
  • Startup is chargeable (MANDATORY), type XSTARTUPJ with quotation on demand and with startup report according to Auer standards

Applicable boiler

  • Warm water tank 300 liters, type SANI+ 300 R-AQUA
  • Warm water tank 500 liters, type SANI+ 500 R-AQUA

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right

Notes

A: HTI70
B: Bivalent with existing central heating boiler possible
C: DHW-tank optional
D: 2nd circuit DHW or CH

Schematic diagram: see technical manual for the exact connection of the hydraulic connections

Technical data

HTI outdoor unit HTI 6 mono8 mono8 tri11 mono11 tri14 mono14 tri
Maximum water temperature°C70
Maximum heating powerkW68811111414
Rated heating power +7°C/+35°CkW4.176.066.069.019.0111.2111.21
Rated heating power +7°C/+35°CkW0.831.131.131.851.852.292.29
COP +7°C/+35°C 5.055.355.354.864.864.894.89
Heating power -7°C/+65°CkW5.56.856.8511.011.013.013.0
Energy class 35°C/55°C A+++/A++A+++/A+++A+++/A+++A+++/A++A+++/A++A+++/A++A+++/A++
Annual energy consumption KWh/jaar2571313431344894489463246324
Sound level (EN 14825 +7°C/+55°C Aver.)dB(A)56575750506060
Refrigerant (GWP) R290 (3)
Amount of refrigerant R290kg (CO2eq)0.42 (1,26)0.6 (1,8)0.6 (1,8)0.8 (2,4)0.8 (2,4)0.95 (2,85)0.95 (2,85)
Outdoor unit dimensions (HxWxD)mm1035 x 820 x 4801035 x 1070 x 4801035 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 480
Outdoor unit weightkg8498109121126128133
Nominal air flow ratem³/h3500350035007250725080008000
Nominal water flow ratem³/h1.051.351.351.651.651.851.85
Hydraulic connection diametermm26/34 mannelijk
Operating range°C-20°C tot +40°C
Maximum absorbed currentA1515630103010
Power supply outdoor unit 230V230V400V tri230V400V tri230V400V tri
FuseA20 mono20 mono16 tri32 mono16 tri32 mono20 tri
Cable section 3G2,53G2,55G2,53G65G2,53G65G2,5
Power OFF position (POFF) 0.0030.0030.0030.0030.0030.0030.003
Power thermostat OFF (PTO) 0.005
Power standby (PSB) 0.003
Power carter heating (PCK) 0.013

Technical data

Indoor module PILOT Pilote PREMIUM+
Minimum power cable widthmm²3G65G2,5
Circuit breakerA3216
Power supply 230V 1 ph400V 3ph
Multifunctional tankL38
Dimensions Pilote PREMIUM+mmH 845 x L 590 x D 420
Weight of the PILOT without waterkg47
Hydraulic connectionsmm26/34 male
Boiler connection compatible
Electrical back-up heater (as standard)kW0 to 6 kW
Decoupling of circuits Yes

Dimensions

 DescriptionHydraulic connection
1Outgoing water heat pump1"
2Incoming water back-up boiler1"
3Emptying3/4"
4Outgoing water back-up boiler1"
5Incoming water circuit 11"
6Outgoing water circuit 11"
7Incoming water circuit 2 (optional)1"
8Outgoing water circuit 2 (optional)1"
9Incoming water (cold) to heat pump1"
10Safety valve for draining 
    
HTIMinimum required piping diameter
6 kW 8 kW
If distance between heat pump and indoor module >10m[mm]22/2422/24
(or the equivalent of 20m linear pressure losses)
If distance between heat pump and indoor module >10m and <15m[mm]24/628/30
(or the equivalent of 30m lineair drukverlies)
If distance between heat pump and indoor module >15 and <25m[mm]28/3032/34
(or the equivalent of 50m linear pressure losses)
If distance between heat pump and indoor module >25m and <50m[mm]32/3436/38
(or the equivalent of 100m linear pressure losses)
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...