HTI PREMIUM+ • Inverter high temperature heat pump 70°C

The HTI air/water heat pump uses heat from nature and converts it into usable hot water. The construction of the unit makes it possible to heat water up to 70°C at negative outside temperatures without using a resistance. The unit guarantees good operation down to -20°C outside temperature. The natural refrigerant R290 (propane) has a GWP value of 3 and is therefore hundreds of times better than alternative refrigerants. The HTI is a single heating unit that uses a scroll compressor to ensure a good operation in part load and a low power consumption. Due to the special construction of the unit, the unit will have to defrost less often and the defrost cycle will be completed as efficiently as possible. The unit maintains its high COP values even at negative outside temperatures.

Brand

  • Auer - Intuis

Application

  • Production of domestic hot water
  • Floor heating
  • Fan coils
  • Radiators

Appropriate for:
  • Renovation of houses

Composition

Monoblock outdoor unit HTI70 6-8-11-14 kW including:

  • Communication bus cable 10 m long HTI/ Pilote (3-wired and already connected to the HTI) (do not connect in parallel with the power cable).
  • Flexible hose (Durite) 1 m long => rest in an insulated rigid pipe towards the indoor module (diameter depending on the distance between the two, see table below).
  • Ball valve with integrated filter to be mounted on the return connection.
  • Overpressure valve 2.5 bar to be mounted on the flow connection.


Indoor module Pilote PREMIUM+:

  • 1x primary + 1x secondary pump
  • Buffer tank/ hydraulic decoupling bottle 38 liters with air purge and drain valve
  • Extra hydraulic connection for bivalent operation with boiler
  • Adjustable backup resistance 0-6 kW
  • Pressure sensor
  • Flow meter
  • Electronic regulation
  • USB stick (included with manual)
  • Outdoor sensor for weather dependent control

Installation

  • When combining production of DHW with central heating water, an extra pump and a DHW S HRC70 sensor must be provided.
  • The addition of an anti-corrosion agent or a glycol/anti-corrosion mixture is mandatory.

Accessories

  • Room thermostat TH HRC70
  • Domestic hot water sensor DHW S HRC70
  • Additional secondary pump HRC PK Premium+
  • Regulation on 2nd circuit with lower water temperature THORIX
  • Clean existing heating systems first.
  • Startup is chargeable (MANDATORY), type XSTARTUPJ with quotation on demand and with startup report according to Auer standards

Applicable boiler

  • Warm water tank 300 liters, type SANI+ 300 R-AQUA
  • Warm water tank 500 liters, type SANI+ 500 R-AQUA

Articles

Article selection assistant
Dia [mm]
Color
Q Intake (2,5 m/s in the duct) [m³/h]
Q Outtake (3,5 m/s in the valve) [m³/h]
Article number Type Dia [mm] Color Q Intake (2,5 m/s in the duct) [m³/h] Q Outtake (3,5 m/s in the valve) [m³/h] E-shop
A090101125000 CT125R 125 Red 105 147
A090101150000 CT150R 150 Red 153 214
A090101160000 CT160R 160 Red 153 214
A090101200000 CT200R 200 Red 275 384
A090101250000 CT250R 250 Red 431 604
A090101315000 CT315R 315 Red 689 964
A090101355000 CT355R 355 Red 876 1226
A090101400000 CT400R 400 Red 1114 1560
A090101450000 CT450R 450 Red 1412 1977
A090101500000 CT500R 500 Red 1746 2444
A090101630000 CT630R 630 Red 2779 3891
A090102125000 CT125B 125 Gray 105 147
A090102150000 CT150B 150 Gray 153 214
A090102160000 CT160B 160 Gray 153 214
A090102200000 CT200B 200 Gray 275 384
A090102250000 CT250B 250 Gray 431 604
A090102315000 CT315B 315 Gray 689 964
A090102355000 CT355B 355 Gray 876 1226
A090102400000 CT400B 400 Gray 1114 1560
A090102450000 CT450B 450 Gray 1412 1977
A090102500000 CT500B 500 Gray 1746 2444
A090102630000 CT630B 630 Gray 2779 3891
=> Stock product central warehouse, except sales
=> Stock product local warehouses, except sales
=> Article with a volume discount

Notes

A: HTI70
B: Bivalent with existing central heating boiler possible
C: DHW-tank optional
D: 2nd circuit DHW or CH

Schematic diagram: see technical manual for the exact connection of the hydraulic connections

Technical data

HTI outdoor unit HTI 6 mono8 mono8 tri11 mono11 tri14 mono14 tri
Maximum water temperature°C70
Maximum heating powerkW68811111414
Rated heating power +7°C/+35°CkW4.176.066.069.019.0111.2111.21
Rated heating power +7°C/+35°CkW0.831.131.131.851.852.292.29
COP +7°C/+35°C 5.055.355.354.864.864.894.89
Heating power -7°C/+65°CkW5.56.856.8511.011.013.013.0
Energy class 35°C/55°C A+++/A++A+++/A+++A+++/A+++A+++/A++A+++/A++A+++/A++A+++/A++
Annual energy consumption KWh/jaar2571313431344894489463246324
Sound level (EN 14825 +7°C/+55°C Aver.)dB(A)56575750506060
Refrigerant (GWP) R290 (3)
Amount of refrigerant R290kg (CO2eq)0.42 (1,26)0.6 (1,8)0.6 (1,8)0.8 (2,4)0.8 (2,4)0.95 (2,85)0.95 (2,85)
Outdoor unit dimensions (HxWxD)mm1035 x 820 x 4801035 x 1070 x 4801035 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 4801235 x 1070 x 480
Outdoor unit weightkg8498109121126128133
Nominal air flow ratem³/h3500350035007250725080008000
Nominal water flow ratem³/h1.051.351.351.651.651.851.85
Hydraulic connection diametermm26/34 mannelijk
Operating range°C-20°C tot +40°C
Maximum absorbed currentA1515630103010
Power supply outdoor unit 230V230V400V tri230V400V tri230V400V tri
FuseA20 mono20 mono16 tri32 mono16 tri32 mono20 tri
Cable section 3G2,53G2,55G2,53G65G2,53G65G2,5
Power OFF position (POFF) 0.0030.0030.0030.0030.0030.0030.003
Power thermostat OFF (PTO) 0.005
Power standby (PSB) 0.003
Power carter heating (PCK) 0.013

Technical data

Indoor module PILOT Pilote PREMIUM+
Minimum power cable widthmm²3G65G2,5
Circuit breakerA3216
Power supply 230V 1 ph400V 3ph
Multifunctional tankL38
Dimensions Pilote PREMIUM+mmH 845 x L 590 x D 420
Weight of the PILOT without waterkg47
Hydraulic connectionsmm26/34 male
Boiler connection compatible
Electrical back-up heater (as standard)kW0 to 6 kW
Decoupling of circuits Yes

Dimensions

 DescriptionHydraulic connection
1Outgoing water heat pump1"
2Incoming water back-up boiler1"
3Emptying3/4"
4Outgoing water back-up boiler1"
5Incoming water circuit 11"
6Outgoing water circuit 11"
7Incoming water circuit 2 (optional)1"
8Outgoing water circuit 2 (optional)1"
9Incoming water (cold) to heat pump1"
10Safety valve for draining 
    
HTIMinimum required piping diameter
6 kW 8 kW
If distance between heat pump and indoor module >10m[mm]22/2422/24
(or the equivalent of 20m linear pressure losses)
If distance between heat pump and indoor module >10m and <15m[mm]24/628/30
(or the equivalent of 30m lineair drukverlies)
If distance between heat pump and indoor module >15 and <25m[mm]28/3032/34
(or the equivalent of 50m linear pressure losses)
If distance between heat pump and indoor module >25m and <50m[mm]32/3436/38
(or the equivalent of 100m linear pressure losses)
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...