PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

HRC70 040 ZéPAC HEAT COOL • High temperature air/water heat pumps 70°C HEATING/COOLING

This HRC70 40 ZéPAC is an air/water heat pump that is suitable for heating and cooling. The water can be heated to high temperatures. The monoblock unit is filled with natural refrigerant propane (R290) and easily reaches water temperatures up to 70°C. The device guarantees proper operation at outside temperatures down to -20°C.
The HRC70 40 ZéPAC is a heating/cooling unit that uses 2 scroll compressors of equal capacity, which are equipped with soft starters as standard. This ensures 2 power stages and low power consumption. Due to the specific construction, the device will switch to defrost mode less often and the defrost cycle will be completed as efficiently as possible.
The unit maintains its high COP values even at negative outside temperatures. Possibility to cascade 2 HRC70 40 Zépac heating/cooling devices with a total power of 80 kW.

Brand

  • Auer - Intuis

Application

  • Production of domestic hot water
  • Floor heating or cooling
  • Fan coils heating or cooling
  • Radiators only heating
  • Also available in a cascade of 2 reversible HRC70 40 on 1 Pilote ZéPAC

Composition

Monoblock heat pump (outdoor unit) HRC70 40 kW with :

  • Flexible pipes (Durite) of 5 m long and rigid insulated pipe to indoor module (diameter according to distance between the two, see table at the bottom of this page).
  • Filter 1"1/4 already installed in the return duct of the heat pump.
  • Primary pump already installed in the heat pump.
  • 2,5 bar pressure relief valve mounted in the heat pump.


Indoor module ZéPAC Uni-module 1x Pilote:
  • Buffertank/hydraulic découpling bottle 78L with air vent and release valve
  • 50 m long bus cable for communication between the HRC70 and the ZéPAC (do not place in parallel with power cable).
  • Pressure sensor
  • 6 bar safety valve
  • Flow meter
  • Electronic CAREL regulation
  • USB stick (comes with manual)
  • 4 x Shut-off valve on the left-side
  • Sludge valve

Installation

  • The addition of an anti-corrosion agent or a glycol/anti-corrosion mixture is mandatory.

Accessories

  • Wireless room thermostat TH NCR/2 radio
  • DHW sensor DHW S HRC70
  • Extra secondary pump HRC PK ZéPAC
  • Startup is chargeable (MANDATORY), type XSTARTUPJ, quotation available upon request

Applicable boiler

  • Domestic hot water tank 300 liters, type SANI+ 300 R-AQUA
  • Domestic hot water tank 500 liters, type SANI+ 500 R-AQUA

Articles

Article selection assistant
Diameter [mm]
Airflow range [m³/h]
Factory setpoint [m³/h]
Article number Type Diameter [mm] Airflow range [m³/h] Factory setpoint [m³/h] E-shop
B020102080015 KVR-R Ø80 15m³/h 80 15 - 50 15
B020102080025 KVR-R Ø80 25m³/h 80 15 - 50 25
B020102080030 KVR-R Ø80 30m³/h 80 15 - 50 30
B020102080045 KVR-R Ø80 45m³/h 80 15 - 50 45
B020102080050 KVR-R Ø80 50m³/h 80 15 - 50 50
B020102100015 KVR-R Ø100 15m³/h 100 15 - 50 15
B020102100025 KVR-R Ø100 25m³/h 100 15 - 50 25
B020102100030 KVR-R Ø100 30m³/h 100 15 - 50 30
B020102100045 KVR-R Ø100 45m³/h 100 15 - 50 45
B020102100050 KVR-R Ø100 50m³/h 100 15 - 50 50
B020102100060 KVR-R Ø100 60m³/h 100 51 - 100 60
B020102100075 KVR-R Ø100 75m³/h 100 51 - 100 75
B020102100090 KVR-R Ø100 90m³/h 100 51 - 100 90
B020102100100 KVR-R Ø100 100m³/h 100 51 - 100 100
B020102125015 KVR-R Ø125 15m³/h 125 15 - 50 15
B020102125025 KVR-R Ø125 25m³/h 125 15 - 50 25
B020102125030 KVR-R Ø125 30m³/h 125 15 - 50 30
B020102125045 KVR-R Ø125 45m³/h 125 15 - 50 45
B020102125050 KVR-R Ø125 50m³/h 125 15 - 50 50
B020102125060 KVR-R Ø125 60m³/h 125 51 - 100 60
B020102125075 KVR-R Ø125 75m³/h 125 51 - 100 75
B020102125090 KVR-R Ø125 90m³/h 125 51 - 100 90
B020102125100 KVR-R Ø125 100m³/h 125 51 - 100 100
B020102125120 KVR-R Ø125 120m³/h 125 101 - 180 120
B020102125150 KVR-R Ø125 150m³/h 125 101 - 180 150
B020102125180 KVR-R Ø125 180m³/h 125 101 - 180 180
B020102150050 KVR-R Ø150 50m³/h 150 15 - 50 50
B020102150100 KVR-R Ø150 100m³/h 150 51 - 100 100
B020102150120 KVR-R Ø150 120m³/h 150 101 - 180 120
B020102150150 KVR-R Ø150 150m³/h 150 101 - 180 150
B020102150180 KVR-R Ø150 180m³/h 150 101 - 180 180
B020102150210 KVR-R Ø150 210m³/h 150 181 - 300 210
B020102150240 KVR-R Ø150 240m³/h 150 181 - 300 240
B020102150250 KVR-R Ø150 250m³/h 150 181 - 300 250
B020102150270 KVR-R Ø150 270m³/h 150 181 - 300 270
B020102150300 KVR-R Ø150 300m³/h 150 181 - 300 300
B020102160050 KVR-R Ø160 50m³/h 160 15 - 50 50
B020102160100 KVR-R Ø160 100m³/h 160 51 - 100 100
B020102160120 KVR-R Ø160 120m³/h 160 101 - 180 120
B020102160150 KVR-R Ø160 150m³/h 160 101 - 180 150
B020102160180 KVR-R Ø160 180m³/h 160 101 - 180 180
B020102160210 KVR-R Ø160 210m³/h 160 181 - 300 210
B020102160240 KVR-R Ø160 240m³/h 160 181 - 300 240
B020102160250 KVR-R Ø160 250m³/h 160 181 - 300 250
B020102160270 KVR-R Ø160 270m³/h 160 181 - 300 270
B020102160300 KVR-R Ø160 300m³/h 160 181 - 300 300
B020102200180 KVR-R Ø200 180m³/h 200 101 - 180 180
B020102200210 KVR-R Ø200 210m³/h 200 181 - 300 210
B020102200240 KVR-R Ø200 240m³/h 200 181 - 300 240
B020102200250 KVR-R Ø200 250m³/h 200 181 - 300 250
B020102200270 KVR-R Ø200 270m³/h 200 181 - 300 270
B020102200300 KVR-R Ø200 300m³/h 200 181 - 300 300
B020102200350 KVR-R Ø200 350m³/h 200 301 - 500 350
B020102200400 KVR-R Ø200 400m³/h 200 301 - 500 400
B020102200450 KVR-R Ø200 450m³/h 200 301 - 500 450
B020102200500 KVR-R Ø200 500m³/h 200 301 - 500 500
B020102250300 KVR-R Ø250 300m³/h 250 181 - 300 300
B020102250350 KVR-R Ø250 350m³/h 250 301 - 500 350
B020102250400 KVR-R Ø250 400m³/h 250 301 - 500 400
B020102250450 KVR-R Ø250 450m³/h 250 301 - 500 450
B020102250500 KVR-R Ø250 500m³/h 250 301 - 500 500
B020102250550 KVR-R Ø250 550m³/h 250 501 - 700 550
B020102250600 KVR-R Ø250 600m³/h 250 501 - 700 600
B020102250650 KVR-R Ø250 650m³/h 250 501 - 700 650
B020102250700 KVR-R Ø250 700m³/h 250 501 - 700 700
=> Stock product central warehouse, except sales
=> Stock product local warehouses, except sales

Notes

1. Buffer tank 78L
2. Electronic regulation
3. Drain valve

Technical data

Technical specifications HRC70 40 ZéPAC HEAT COOL
Maximum water temperature°C70
Maximum heating capacitykW41
Heating capacity +7°C/+35°CkW33
COP +7°C/+35°C 4,20
Heating capacity +7°C/+45°CkW31
Heating capacity +7°C/+55°CkW30,5
Heating capacity -7°C/+35°CkW25
Heating capacity -7°C/+45°CkW24
Heating capacity -7°C/+65°CkW22
Cooling capacity 35°C Ext. 7/12°C WaterkW24,58
Energy class 35C°/55C° A+
Annual energy consumptionkWh/year16093
Operating range°C-20°C ~ +40°C
Outdoor unit dimensions HxWxDmm1545 x 1630 x 1200
Weightkg425
Air flow ratem³/h6000 to 12000
Rated water flow ratem³/h4,7
Condensate drain connectionG F1"
Hydraulic connection diameterVictualic/Rainuré40/49 male
Sound level @ 1m 1 / 2 CompressorsdB(A)52/61
Refrigerant (GWP) R290 (3)
Amount of refrigerant R290kg3,6 (0,702)
Power supply 3 x 400V + N
FuseA32 (D)
Cable section outdoor unitA5G6
Maximum absorbed currentA26,3
Maximum starting currentA54
Power position OFF (POFF)kW0,0077
Power thermostat OFF (PTO)kW0,0117
Power standby (PSB)kW0,0077
Power carter heating (PCK)kW0,0117

Technical data

Indoor module PILOTE ZéPAC Uni-module 1x Pilote
Power supply 230V/1 ph
Minimum power cable diametermm²3G 2,5
Circuit breakerA20
Multifunctional tankL78
Dimensions ZéPAC Uni-module (WxHxD)mm509 x 1401 x 550
Weight Pilote ZéPAC without waterkg51
Number of hydraulic connections 10

Dimensions

Minimum required piping diameter between HRC70 40 and ZéPACDepending on the tube used
1 Heatpump on 1 pilote ZéPACSteelCopperPER-tube
If distance between heat pump and indoor module >10 m and <20 m34,3 mm26 mm26 mm
If distance between heat pump and indoor module >20 m and <35 m40,5 mm30,9 mm30,9 mm
If distance between heat pump and indoor module >35 m and <50 m45,9 mm35,3 mm35,3 mm
If distance between heat pump and indoor module >50 m and <75 m49,4 mm38,2 mm38,2 mm
If distance between heat pump and indoor module >75 m and <100 m52,1 mm40,5 mm40,5 mm
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...