PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

EDEL D Air • Heat pump water heater floor model or floor mounting

Heat pump water heater for heating of sanitary water. Thanks to the A + label, the heat pump is extremely economical. The extra sound insulation ensures that the device is very quiet. The reservoir is made of stainless steel and has a volume of 200 or 270 liters. This allows domestic hot water to be provided for 5 or 6 people. The appliance has a patented eHD heat exchanger with microchannels, made of aluminum, which has the advantage that they are not in contact with the sanitary water.

Brand

  • Auer - Intuis

Application

  • Production of domestic hot water for household use

Product

  • Stainless steel water tank (AISI 444) of 200 or 270 liters
  • The aluminum heat exchanger of the heat pump is located around the tank and not in the tank: this ensures a separation between the refrigerant and the hot water
  • The Solar version (ECH SOLAR) is equipped with an additional heat exchanger for the connection of solar collectors
  • Energy label A+ with a COP up to 3.08 according to EN16147
  • Low-noise device of only 33 dB (A) (fan motor is fully encapsulated in insulation material)

  • Production of domestic hot water possible from 30°C to 60°C (65°C with resistance)
  • Tank insulation PU 50 mm
  • Anti-legionella cycle
  • Heating capacity of the heat pump: 2.2 kW
  • Electric back-up resistance of 1.2 kW
  • Boost function
  • Holiday mode
  • Potential-free contact "PV mode active" higher sentpoint during PV production
  • The device comes standard with a handy carrying bag to put the water heater in place
  • Safety group of 7 Bar max. pressure MUST be placed on the cold water supply pipe - connect to the drain pipe.

Refrigerant

  • Refrigerant R290 (GWP = 3)

Installation

  • Smart Grid ready
  • Electrical supply to be connected via an electrical distribution box (there's no plug)

Accessories

  • Insulated duct (2m), type ISDR 200/170
  • Insulated bend, type ISDR BD90/45° 200/170
  • Connecting piece, type ISDR MS 200/150 (transition diam. 160mm EDEL to ISDR 200/170)
  • Wall passage, type ISDR BLR 200/170
  • Roof passage, type ISDR DDI 200/170
  • Suspension bracket, type OBMC 200, for mounting the ducts with outer diameter 200
  • Connection piece, type MDV 160
  • Spiral duct, type SD 160 (insulation required)
  • Filter boxes FLK-BN

Technical data

  Edel D200 AirEdel D270 AirEdel D270 Air ECH SOLAR
Volumel200270
Max. heating capacity heat pump + electrical resistanceW34473356
Heating capacity heat pumpW22472156
Absorbed power compressorW700700
Integrated electrical back-up heaterW12001200
Temperature range°C-7 to +35-7 to +35
Temperature domestic hot water with heat pump°C30 to 6030 to 60
Flow ratem³/h320 to 400320 to 400
Static pressure ventilator*Pa170170
Sound pressure level at 2 mdB(A)3333
Refrigerant (GWP) R290 (3)R290 (3)
Precharged quantity of refrigerantg(CO2eq-kg)150 (0,45)150 (0,45)
COP (outdoor temperature +7°C) 3.213.08
COP (indoor temperature +15°C) 3.33.2
SEER%130128
Heating time 6h139h58
Energy class A+ (at 7°C)A+ (at 7°C)
DimensionsmmØ 630 x 1470 HØ 630 x 1748 H
Weigth (net)kg56,56386
Connection diameter of air duct (supply/discharge)mm2 x 1602 x 160
Maximum length of air ductmFlexible duct: 10 m (supply + discharge)Flexible duct: 10 m (supply + discharge)
Rigid duct: 20 m (supply + discharge)Rigid duct: 20 m (supply + discharge)
Hydraulic connection diameterinchM 3/4"M 3/4"
Power supplyV - Hz - A230 V - 50 Hz - 10 A230 V - 50 Hz - 10 A
Protection class IPX4IPX4
Tank insulation Polyurethane foam 50mmPolyurethane foam 50mm
Tank material InoxInox
Maximum condensation flow ratel/h0.30.3
Maximum temperature with electrical back-up resistance°C6565
Integrated heat exchangerm²/kW--0,9/20
Connection diameter of intagrated heat exchangerinch--M 3/4"
* Static back-pressure measured at 320m³ / h

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...