Set for connecting the air intake and air outlet of the Edel 150 with wall passage. Concentric connection with diameter of 125/80 mm and length of 370 or 990 mm. The concentric design of the duct ensures simultaneous air intake and air outlet. This system is designed to meet both thermal and acoustic requirements. The tube is provided with an access cover for easy maintenance. In the cold months, this cover can be removed to partly use indoor air for an increased COP.
Brand
Auer - Intuis
Application
Suited for installation with heat pump water heater Edel 150 Air
Suited for horizontal or vertical mounting
Composition
T-shaped tube made of insulating polyolefin foam with a
length of 370 mm (EDEL CON 370)
T-shaped tube made of insulating polyolefin foam with a
length of 990 mm (EDEL CON 990)
90 ° PVC bend
Access cover
Wall passage with rubber
Installation
First place the female side of the elbow with a diameter of 80 mm (1) on the EDEL AIR 150 (inner ring) on the other side (male) of this elbow, place the hose (3) which you tighten with 1 of the tension straps (8)
Place the 2 half-T-pieces (4) on top of each other to form a 125 mm diameter T-piece and push it also onto the EDEL AIR 150 (outer ring)
At one end of this newly assembled Tee, place the end cover (5) (can be removed to take in room air, instead of outside air)
At the other end of this T, place the connecting piece containing the hose (2)
On the one hand, the insulated extension 125 mm in diameter (6) is connected to this connecting piece and to the central flexible (and to the 2 nd clamping collar (2)) a fixed PVC conduit 80 mm in diameter is connected ( this PVC conduit is not included and is not part of the CAIROX range)
Make a hole in the outer wall with the same diameter as the outer diameter of the collar of the suction/delivery valve (9) and place this valve in the outer wall. Finish the valve with the external rosette supplied with gasket (10)
You can connect the fixed pipe with a diameter of 80 mm to this valve (9) in the middle.
Place the interior rosette (7) against the inside of the exterior wall around the opening and mount the insulated extension 125 mm diameter (6)
Specifications
EDEL CON 370 length = 370mm
EDEL CON 990 length = 990mm
Very easy installation
Easy to maintain thanks to access cover
High thermal insulation value, to prevent condensation