Set for connecting the air intake and air outlet of the Edel 150 with wall passage. Concentric connection with diameter of 125/80 mm and length of 370 or 990 mm. The concentric design of the duct ensures simultaneous air intake and air outlet. This system is designed to meet both thermal and acoustic requirements. The tube is provided with an access cover for easy maintenance. In the cold months, this cover can be removed to partly use indoor air for an increased COP.

Brand

  • Auer - Intuis

Application

  • Suited for installation with heat pump water heater Edel 150 Air
  • Suited for horizontal or vertical mounting

Composition

  • T-shaped tube made of insulating polyolefin foam with a length of 370 mm (EDEL CON 370)
  • T-shaped tube made of insulating polyolefin foam with a length of 990 mm (EDEL CON 990)
  • 90 ° PVC bend
  • Access cover
  • Wall passage with rubber

Installation

  • First place the female side of the elbow with a diameter of 80 mm (1) on the EDEL AIR 150 (inner ring) on ​​the other side (male) of this elbow, place the hose (3) which you tighten with 1 of the tension straps (8)
  • Place the 2 half-T-pieces (4) on top of each other to form a 125 mm diameter T-piece and push it also onto the EDEL AIR 150 (outer ring)
  • At one end of this newly assembled Tee, place the end cover (5) (can be removed to take in room air, instead of outside air) At the other end of this T, place the connecting piece containing the hose (2)
  • On the one hand, the insulated extension 125 mm in diameter (6) is connected to this connecting piece and to the central flexible (and to the 2 nd clamping collar (2)) a fixed PVC conduit 80 mm in diameter is connected ( this PVC conduit is not included and is not part of the CAIROX range)
  • Make a hole in the outer wall with the same diameter as the outer diameter of the collar of the suction/delivery valve (9) and place this valve in the outer wall. Finish the valve with the external rosette supplied with gasket (10)
  • You can connect the fixed pipe with a diameter of 80 mm to this valve (9) in the middle.
  • Place the interior rosette (7) against the inside of the exterior wall around the opening and mount the insulated extension 125 mm diameter (6)

Specifications

  • EDEL CON 370 length = 370mm
  • EDEL CON 990 length = 990mm
  • Very easy installation
  • Easy to maintain thanks to access cover
  • High thermal insulation value, to prevent condensation
  • Acoustic damping by using polyolefin foam
  • Outside diameter 160mm
  • PVC pipe diameter 80 not included

Accessories

  • Insulated bend 90 ° 125/80 mm, type IBJ12590
  • Insulated bend 45 ° 125/80 mm, type IBJ12545
  • Concentric duct 2m 80/125mm, type INP 2M
  • Connecting piece, type JFP125
  • Suspension bracket diameter 125, type OBMC 125

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...