PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

HPB 100/150 • Heat pump water heaters for wall mounting 100L/150L

Boiler heat pump for the production of domestic hot water. The heat pump is very energy efficient and has the A+ energy label. Sound insulation ensures silent operation of the boiler. The tank is made of enamelled steel and has a volume of 100 or 150 liters, which allows the production of domestic hot water. The device is equipped with a micro-channel heat exchanger made of aluminum. The main advantage being the absence of contact with water.

Brand

  • R-AQUA

Application

  • Production of domestic hot water

Product

  • Smart Grid Ready
  • Enamelled water tank of 100 or 150 liters (enamelling process at 860°C)
  • The aluminum heat exchanger of the heat pump is located around the water tank instead of in the water tank: this ensures a separation between the refrigerant and the domestic hot water
  • Energy label A+ with a COP up to 2,78 according to EN16147
  • Low-noise operation of only 35,5 dB (A)
  • Production of domestic hot water possible from 38°C to 55°C (60°C with resistance)
  • Anti-legionella cycle
  • Heating capacity of the heat pump: 0,9 kW
  • Electric back-up resistance of 1,5 kW
  • Protection through a magnesium anode
  • Economy, smart or boost function
  • Warning: The safety group (max. pressure 7 bar) is not included. To be provided by the installer and to be mounted on the cold water supply pipe - To be connected to the drain pipe.

Refrigerant

  • R290

Installation

  • Wall mounting (mounting bracket included)

Accessories

  • WiFi module, type HPB(-S) WIFI
  • Insulation coupling, type ISCM

  • Safety group, type PSG

  • Siphon for pressure safety group, type SSG

  • Expansion vessel for sanitary water, type SEV

  • Connection kit for sanitary expansion vessel, type EVC SAN

  • Pressure regulator, type PRV

  • Insulated duct (2m), type ISDR 160/125
  • Insulated bend, type ISDR BD90/45° 160/125
  • Connection piece, type ISDR M 160/160
  • Wall passage, type ISDR BLR 160/125
  • Roof passage, type ISDR DDI 160/125
  • Suspension bracket, type OBMC 160, for mounting of ducts with outer diameter 160

Artikelen

Artikelselectie-assistent
Type
Koelvermogen* [kW]
Verwarmingsvermogen* [kW]
Wateraansluiting
Artikelnummer Type Koelvermogen* [kW] Verwarmingsvermogen* [kW] Wateraansluiting E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Links
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Links
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Links
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Links
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Links
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Links
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Rechts
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Rechts
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Rechts
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Rechts
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Rechts
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Rechts
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Links
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Links
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Links
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Links
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Links
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Links
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Rechts
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Rechts
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Rechts
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Rechts
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Rechts
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Rechts
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Links
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Links
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Links
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Links
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Links
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Links
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Rechts
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Rechts
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Rechts
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Rechts
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Rechts
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Rechts
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Links
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Links
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Links
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Links
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Links
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Links
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Rechts
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Rechts
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Rechts
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Rechts
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Rechts
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Rechts
* (Koeling) Binnen temp.: 27°C ruimtetemp. - Waterregime.: 7°C ingaand /12°C uitgaand op middensnelheid (Verwarming) Binnen temp.: 20°C - Waterregime.: 45°C ingaand /40°C Uitgaand op middensnelheid.

Technical data

  HPB 100HPB 150
Volumel100150
Max. heating capacity heat pump + electrical resistanceW24002400
Heating capacity heat pump *W900900
Absorbed power compressorW250250
Built-in electrical backup resistanceW15001500
Operating temperature range°C-5 ~ 43-5 ~ 43
Temperature DHW with heat pump°C38 ~ 5538 ~ 55
Air flow ratem³/h250250
Static fan pressurePa2020
Sound pressure level at 1 mdB(A)35,5037,00
Refrigerant (GWP) R290 (3)R290 (3)
Precharged quantity of refrigerantg(CO2eq-kg)150 (0,45)150 (0,45)
Heating time*h5h107h45
COP (outdoor temperature +7°C)** 2,582,78
COP (indoor temperature +14°C)** 2,732,87
Seasonal energy efficiency ratio (outdoor temperature +7°C)**%110,30115,70
Energy class (outdoor temperature +7°C)** A+A+
DimensionsmmØ560 X 1117 HØ560 X 1430 H
Weight (net)kg6871
Connection diameter of air duct (supply/discharge)mm2 x 1252 x 125
Hydraulic connection diameterinch1/2"1/2"
Power supplyV / Ph / Hz230/1/50230/1/50
Automatic fuseA1616
Protection class IPX1IPX1
Tank material Enamelled steelEnamelled steel
Maximum operating pressurebar77
Maximum temperature with electrical back-up resistance°C6060
* Test conditions: ambient temp.: 20°C D.B. /15°C W.B., water inlet/outlet temp.: 15°C /55°C
** Test conditions according to standard EN 16147: ambient temp.: 20°C D.B. /15°C W.B., water inlet/outlet temp.: 10°C /55°C

Dimensions

  HPB 100HPB 150
Amm11171430
Bmm352352
Cmm200200
Dmm305305
Emm275520
FmmØ560Ø560
GmmØ125Ø125