PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

CGW-OU A1 • A2W inverter outdoor units R32

Outdoor unit for air/water heat pump with refrigerant R32 and a DC inverter controlled compressor, to be used in combination with a hydromodule type CGW-IU A1 or CGW-ID A1 (with integrated water heater). The DC rotary compressor guarantees an economical, quiet operation and a long service life.

This outdoor unit is only sold as a set in combination with the indoor unit CGW-IU A1 or CGW-ID A1
CGW-IU A1: 6, 8, 10, 12, 14 and 16 kW
CGW-ID A1: 6, 8, 10, 12, 14 and 16 kW

Brand

  • R-AQUA

Composition

  • Integrated outside temperature sensor

  • DC inverter-controlled two-stage compressor with gas injection
  • DC fan motor
  • Gold Fin condenser

Refrigerant

  • R32

Specifications

  • Split system
  • Robust and compact
  • Easy installation
  • Valve protection
  • Operating range in cooling at outdoor temperatures from +10°C to +48°C
  • Operating range in heating at outdoor temperatures from -25°C to +35°C

Accessories

  • Anti-vibration mounting blocks, type MPRH
  • Insulated copper pipes, type P-COIL

Applicable indoor units

  • Hydromodule, type CGW-IU A1
  • Hydromodule with integrated water heater, type CGW-ID A1

Startup

  • Start up by CAIROX BELGIUM strongly recommended

Technical data

Technical specifications CGW-OU 06 A1CGW-OU 08 A1CGW-OU 10 A1CGW-OU 12 A1CGW-OU 14 A1CGW-OU 16 A1
Refrigerant (GWP) R32 (675)R32 (675)R32 (675)R32 (675)R32 (675)R32 (675)
Maximum air flow ratem³/h320033003300501450145014
Power
supply
V / Ph / Hz230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50
Rated current (H/C)A10,0/11,013,5/20,015,0/22,017,8/25,620,9/28,722,6/30,3
Compressor power inputkW1,232,142,143,253,253,25
Compressor type Inverter rotaryInverter rotaryInverter rotaryInverter rotaryInverter rotaryInverter rotary
Sound power level*dB626768686868
Sound pressure level @ 1m*dB(A)525555575858
Sound pressure level @ 5m**dB(A)404546464646
Dimensions (L x D x H)mm975x396x702982x427x787982x427x787940x460x820940x460x820940x460x820
Weightkg558282104104104
Refrigerant pipes (liquid - gas)inch1/4 - 1/21/4 - 1/21/4 - 1/21/4 - 5/81/4 - 5/81/4 - 5/8
Amount of prefilled refrigerantg (CO2eq-T)1100 (0,74)1840 (1,242)1840 (1,242)1840 (1,242)1840 (1,242)1840 (1,242)
Extra amount of refrigerant per meterg/m161616161616
Number of prefilled metersm101010101010
Maximum length/height of refrigerant pipesm/m20/1525/1525/1525/1525/1525/15
Minimum length of refrigerant pipesm555555
Operating temperature in cooling°C+10 ~ +48+10 ~ +48+10 ~ +48+10 ~ +48+10 ~ +48+10 ~ +48
Operating temperature in heating°C-25 ~ +35-25 ~ +35-25 ~ +35-25 ~ +35-25 ~ +35-25 ~ +35
Operating temperature DHW°C-25 ~ +45-25 ~ +45-25 ~ +45-25 ~ +45-25 ~ +45-25 ~ +45
Power supply cable sectionmm²3G2,53G43G43G63G63G6
Automatic fuse (slow)A162525323232
Specifications and design can be modified for further improvement without prior notice
* Measured according to EN12102
** Lp measured at 5m in free field (Q=2)