Outdoor unit for air/water heat pump with refrigerant R32 and a DC inverter controlled compressor, to be used in combination with a hydromodule type CGW-IU A1 or CGW-ID A1 (with integrated water heater). The DC rotary compressor guarantees an economical, quiet operation and a long service life.
This outdoor unit is only sold as a set in combination with the indoor unit CGW-IU A1 or CGW-ID A1
CGW-IU A1: 6, 8, 10, 12, 14 and 16 kW
CGW-ID A1: 6, 8, 10, 12, 14 and 16 kW
Startup
- Start up by CAIROX BELGIUM strongly recommended
Technical data
|
Refrigerant (GWP) | | R32 (675) | R32 (675) | R32 (675) | R32 (675) | R32 (675) | R32 (675) | Maximum air flow rate | m³/h | 3200 | 3300 | 3300 | 5014 | 5014 | 5014 | Power
supply | V / Ph / Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | Rated current (H/C) | A | 10,0/11,0 | 13,5/20,0 | 15,0/22,0 | 17,8/25,6 | 20,9/28,7 | 22,6/30,3 | Compressor power input | kW | 1,23 | 2,14 | 2,14 | 3,25 | 3,25 | 3,25 | Compressor type | | Inverter rotary | Inverter rotary | Inverter rotary | Inverter rotary | Inverter rotary | Inverter rotary | Sound power level* | dB | 62 | 67 | 68 | 68 | 68 | 68 | Sound pressure level @ 1m* | dB(A) | 52 | 55 | 55 | 57 | 58 | 58 | Sound pressure level @ 5m** | dB(A) | 40 | 45 | 46 | 46 | 46 | 46 | Dimensions (L x D x H) | mm | 975x396x702 | 982x427x787 | 982x427x787 | 940x460x820 | 940x460x820 | 940x460x820 | Weight | kg | 55 | 82 | 82 | 104 | 104 | 104 | Refrigerant pipes (liquid - gas) | inch | 1/4 - 1/2 | 1/4 - 1/2 | 1/4 - 1/2 | 1/4 - 5/8 | 1/4 - 5/8 | 1/4 - 5/8 | Amount of prefilled refrigerant | g (CO2eq-T) | 1100 (0,74) | 1840 (1,242) | 1840 (1,242) | 1840 (1,242) | 1840 (1,242) | 1840 (1,242) | Extra amount of refrigerant per meter | g/m | 16 | 16 | 16 | 16 | 16 | 16 | Number of prefilled meters | m | 10 | 10 | 10 | 10 | 10 | 10 | Maximum length/height of refrigerant pipes | m/m | 20/15 | 25/15 | 25/15 | 25/15 | 25/15 | 25/15 | Minimum length of refrigerant pipes | m | 5 | 5 | 5 | 5 | 5 | 5 | Operating temperature in cooling | °C | +10 ~ +48 | +10 ~ +48 | +10 ~ +48 | +10 ~ +48 | +10 ~ +48 | +10 ~ +48 | Operating temperature in heating | °C | -25 ~ +35 | -25 ~ +35 | -25 ~ +35 | -25 ~ +35 | -25 ~ +35 | -25 ~ +35 | Operating temperature DHW | °C | -25 ~ +45 | -25 ~ +45 | -25 ~ +45 | -25 ~ +45 | -25 ~ +45 | -25 ~ +45 | Power supply cable section | mm² | 3G2,5 | 3G4 | 3G4 | 3G6 | 3G6 | 3G6 | Automatic fuse (slow) | A | 16 | 25 | 25 | 32 | 32 | 32 | Specifications and design can be modified for further improvement without prior notice | * Measured according to EN12102 | ** Lp measured at 5m in free field (Q=2) |
|