PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

CWP-M • Air/water heat pumps R290 Monoblock

  • R-AQUA
  • Air/water monoblock
  • Outdoor unit
  • R290
  • 4 - 17 kW

The CWP-M is a DC inverter controlled monoblock heat pump with R290 refrigerant.

By using the natural refrigerant R290 with a GWP value of only 3, the heat pump uses the heat in the outdoor air in an environmentally friendly and cost-saving way to heat, cool and provide your home with sanitary hot water. The construction of the unit makes it possible to heat water up to 75°C at outdoor temperatures down to -7°C without using a resistance. The unit guarantees proper operation down to -25°C outside temperature. The fully bubble-foam-lined interior, the compartmentalized compressor, the acoustically optimized fan and blades contribute to extremely quiet operation. The exterior of the monoblock is made of ASA plastic, making it resistant to all weather conditions. The contemporary design and anthracite colour are characteristic for this heat pump.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Production of domestic hot water, provided a hot water heater is installed

Composition

  • High efficiency plate heat exchanger
  • Energy-efficient circulation pump
  • User friendly Colour touch screen controller
  • Integrated outside temperature sensor

  • DTU module
(The DTU module uses the 4G network to operate your device via the smartphone WarmLink application)

Refrigerant

  • R290

Specifications

  • Monobloc system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 75°C at outside temperatures down to -7°C
  • A+++ at 35°C water temperature
  • Standard equipped with a DTU module
  • Standard equipped with a Modbus interface
  • Easy installation

Accessories

  • Automatic gas separator R290, type PGS
  • Anti-vibration mounting blocs, type MPRH
  • Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Buffer tank, type BTE 60, BTE 100
  • 3-way zone valve, type TWV
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Y-strainer, type YDS

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group, anti-freeze protection and expansion vessel MUST be provided on site.

Applicable indoor units

The CWP-M monoblock can operate autonomously or in combination with the following hydro modules:
  • Type CWP-IU A1 (single phase)
  • Type CWP-IU M1 (three-phase)

Applicable boiler

  • Domestic hot water heater 200 liters, type SANI-EM 200
  • Domestic hot water heater 300 liters, type SANI-EM 300, SANI 300+
  • Domestic hot water heater 500 liters, type SANI-EM 500, SANI 500+

Three-way valve not included and has to be provided by the installer.

Startup

  • Start-up by CAIROX BELGIUM is strongly recommended

Technical data

Monoblock unitCWP-M 04 A1CWP-M 06 A1CWP-M 08 A1CWP-M 10 A1CWP-M 17 A1CWP-M 10 M1CWP-M 17 M1
Min. - Max heating capacity A7/W35kW1,80 - 6,701,80 - 9,752,40 - 12,304,56 - 14,455,30 - 22,304,56 - 14,456,10 - 22,30
Nom. heating capacity A7/W35kW4,006,008,0010,0017,0010,0017,00
COP A7/W35 4,714,654,604,654,454,654,45
Nom. heating capacity A7/W55kW4,505,507,509,3017,009,3017,00
COP A7/W55 3,212,932,963,052,973,052,97
Nom. heating capacity A2/W35kW4,506,008,0010,0016,0010,0016,00
COP A2/W35 4,003,803,403,303,683,303,68
Nom. heating capacity A2/W55kW4,506,007,809,5016,009,5016,00
COP A2/W55 2,802,502,362,232,352,232,35
Nom. heating capacity A-7/W35kW4,506,008,1010,0016,3010,0016,30
COP A-7/W35 3,553,282,843,062,833,062,83
Nom. heating capacity A-7/W55kW4,705,707,709,7015,009,7015,00
COP A-7/W55 2,242,042,082,141,892,161,91
Nom. heating capacity A-10/W35kW4,505,907,7510,0016,0010,0016,00
Nom. heating capacity A-10/W55kW4,605,207,009,1514,309,0614,44
Nom. cooling capacity A35/W7kW4,005,008,0010,0015,0010,0015,00
EER A35/W7 3,082,782,582,332,502,332,50
Nom. cooling capacity A35/W18kW4,006,008,0010,0017,0010,0017,00
EER A35/W18 4,654,144,003,663,013,663,01
SEER A35 4,804,514,374,704,544,704,54
SCOP W35/W55 4,96/3,594,87/3,464,82/3,534,85/3,654,87/3,614,80/3,534,90/3,65
Seasonal efficiency heat pump ηs W35/W55 195/141192/135190/138191/143192/141189/138193/143
Annual energy consumption heat pump W35/W55kWh1864/27352387/33333252/44624187/55546244/85024232/57486136/8323
Energy class W35/W55 A+++/A++
Refrigerant (GWP) R290 (3)
Amount of refrigerantgr (CO2eq-T)750 (0,002)750 (0,002)800 (0,002)980 (0,003)1400 (0,004)980 (0,003)1400 (0,004)
Power
supply
V / Ph / Hz230/1/50400/3/50
Max. absorbed powerkW2,763,905,106,308,526,309,10
Max. absorbed currentA12,0017,0022,0030,0036,1012,2016,00
Hydraulic connections (supply - return)inch1"
Operating range (min.-max)Heating°C-25 ~ 43
DHW°C-25 ~ 43
Cooling°C10 ~ 43
Uitgoing water temperature (min.-max.)Heating°C15 ~ 75
DHW°C10 ~ 70
Cooling°C5 ~ 20
ComponentsCompressorType-DC Rotary
Absorbed powerW1580158021502860433028604330
FanType DC Motor
Number 1111212
Air flow rate (min.-max.)m³/h800 ~ 2400800 ~ 2800800 ~ 36001000 ~ 40001800 ~ 60001000 ~ 40001800 ~ 6000
Absorbed powerW90105150200240200240
PumpType-High efficiency pump
Regulation-Electronic - Stepless
Capacity (max.)W6060606018060180
Flow rate (nom.)l/h690103013801700290017002900
Discharge hight (head)m5,507,506,805,6010,505,6010,50
Heat exchangerType-Plate heat exchanger
Number-1
Sound power level*dB57586061636163
Sound pressure level @ 1m*dB(A)42454646484648
Sound pressure level @ 5m**dB(A)35363940414041
Power cable section heat pumpmm²3G2,53G43G43G63G65G2,55G2,5
Automatisc fuse (slow) heat pumpA16323240401616
DimensionsDevice (LxDxH)mm1167x407x7951167x407x7951167x407x7951287x458x9281250x540x13301287x458x9281250x540x1330
Weightkg105105120145205159220
Specifications and design can be altered for further improvement without prior notice
Capacities measured according to EN14511
* Measured according to EN12102
** Lp at 5m in free field (Q=2)
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be