Startup
- Start-up by CAIROX BELGIUM is strongly recommended
Technical data
|
Min. - Max heating capacity A7/W35 | kW | 1,80 - 6,70 | 1,80 - 9,75 | 2,40 - 12,30 | 4,56 - 14,45 | 5,30 - 22,30 | 4,56 - 14,45 | 6,10 - 22,30 | Nom. heating capacity A7/W35 | kW | 4,00 | 6,00 | 8,00 | 10,00 | 17,00 | 10,00 | 17,00 | COP A7/W35 | | 4,71 | 4,65 | 4,60 | 4,65 | 4,45 | 4,65 | 4,45 | Nom. heating capacity A7/W55 | kW | 4,50 | 5,50 | 7,50 | 9,30 | 17,00 | 9,30 | 17,00 | COP A7/W55 | | 3,21 | 2,93 | 2,96 | 3,05 | 2,97 | 3,05 | 2,97 | Nom. heating capacity A2/W35 | kW | 4,50 | 6,00 | 8,00 | 10,00 | 16,00 | 10,00 | 16,00 | COP A2/W35 | | 4,00 | 3,80 | 3,40 | 3,30 | 3,68 | 3,30 | 3,68 | Nom. heating capacity A2/W55 | kW | 4,50 | 6,00 | 7,80 | 9,50 | 16,00 | 9,50 | 16,00 | COP A2/W55 | | 2,80 | 2,50 | 2,36 | 2,23 | 2,35 | 2,23 | 2,35 | Nom. heating capacity A-7/W35 | kW | 4,50 | 6,00 | 8,10 | 10,00 | 16,30 | 10,00 | 16,30 | COP A-7/W35 | | 3,55 | 3,28 | 2,84 | 3,06 | 2,83 | 3,06 | 2,83 | Nom. heating capacity A-7/W55 | kW | 4,70 | 5,70 | 7,70 | 9,70 | 15,00 | 9,70 | 15,00 | COP A-7/W55 | | 2,24 | 2,04 | 2,08 | 2,14 | 1,89 | 2,16 | 1,91 | Nom. heating capacity A-10/W35 | kW | 4,50 | 5,90 | 7,75 | 10,00 | 16,00 | 10,00 | 16,00 | Nom. heating capacity A-10/W55 | kW | 4,60 | 5,20 | 7,00 | 9,15 | 14,30 | 9,06 | 14,44 | Nom. cooling capacity A35/W7 | kW | 4,00 | 5,00 | 8,00 | 10,00 | 15,00 | 10,00 | 15,00 | EER A35/W7 | | 3,08 | 2,78 | 2,58 | 2,33 | 2,50 | 2,33 | 2,50 | Nom. cooling capacity A35/W18 | kW | 4,00 | 6,00 | 8,00 | 10,00 | 17,00 | 10,00 | 17,00 | EER A35/W18 | | 4,65 | 4,14 | 4,00 | 3,66 | 3,01 | 3,66 | 3,01 | SEER A35 | | 4,80 | 4,51 | 4,37 | 4,70 | 4,54 | 4,70 | 4,54 | SCOP W35/W55 | | 4,96/3,59 | 4,87/3,46 | 4,82/3,53 | 4,85/3,65 | 4,87/3,61 | 4,80/3,53 | 4,90/3,65 | Seasonal efficiency heat pump ηs W35/W55 | | 195/141 | 192/135 | 190/138 | 191/143 | 192/141 | 189/138 | 193/143 | Annual energy consumption heat pump W35/W55 | kWh | 1864/2735 | 2387/3333 | 3252/4462 | 4187/5554 | 6244/8502 | 4232/5748 | 6136/8323 | Energy class W35/W55 | | A+++/A++ | Refrigerant (GWP) | | R290 (3) | Amount of refrigerant | gr (CO2eq-T) | 750 (0,002) | 750 (0,002) | 800 (0,002) | 980 (0,003) | 1400 (0,004) | 980 (0,003) | 1400 (0,004) | Power
supply | V / Ph / Hz | 230/1/50 | 400/3/50 | Max. absorbed power | kW | 2,76 | 3,90 | 5,10 | 6,30 | 8,52 | 6,30 | 9,10 | Max. absorbed current | A | 12,00 | 17,00 | 22,00 | 30,00 | 36,10 | 12,20 | 16,00 | Hydraulic connections (supply - return) | inch | 1" | Operating range (min.-max) | Heating | °C | -25 ~ 43 | DHW | °C | -25 ~ 43 | Cooling | °C | 10 ~ 43 | Uitgoing water temperature (min.-max.) | Heating | °C | 15 ~ 75 | DHW | °C | 10 ~ 70 | Cooling | °C | 5 ~ 20 | Components | Compressor | Type | - | DC Rotary | Absorbed power | W | 1580 | 1580 | 2150 | 2860 | 4330 | 2860 | 4330 | Fan | Type | | DC Motor | Number | | 1 | 1 | 1 | 1 | 2 | 1 | 2 | Air flow rate (min.-max.) | m³/h | 800 ~ 2400 | 800 ~ 2800 | 800 ~ 3600 | 1000 ~ 4000 | 1800 ~ 6000 | 1000 ~ 4000 | 1800 ~ 6000 | Absorbed power | W | 90 | 105 | 150 | 200 | 240 | 200 | 240 | Pump | Type | - | High efficiency pump | Regulation | - | Electronic - Stepless | Capacity (max.) | W | 60 | 60 | 60 | 60 | 180 | 60 | 180 | Flow rate (nom.) | l/h | 690 | 1030 | 1380 | 1700 | 2900 | 1700 | 2900 | Discharge hight (head) | m | 5,50 | 7,50 | 6,80 | 5,60 | 10,50 | 5,60 | 10,50 | Heat exchanger | Type | - | Plate heat exchanger | Number | - | 1 | Sound power level* | dB | 57 | 58 | 60 | 61 | 63 | 61 | 63 | Sound pressure level @ 1m* | dB(A) | 42 | 45 | 46 | 46 | 48 | 46 | 48 | Sound pressure level @ 5m** | dB(A) | 35 | 36 | 39 | 40 | 41 | 40 | 41 | Power cable section heat pump | mm² | 3G2,5 | 3G4 | 3G4 | 3G6 | 3G6 | 5G2,5 | 5G2,5 | Automatisc fuse (slow) heat pump | A | 16 | 32 | 32 | 40 | 40 | 16 | 16 | Dimensions | Device (LxDxH) | mm | 1167x407x795 | 1167x407x795 | 1167x407x795 | 1287x458x928 | 1250x540x1330 | 1287x458x928 | 1250x540x1330 | Weight | kg | 105 | 105 | 120 | 145 | 205 | 159 | 220 | Specifications and design can be altered for further improvement without prior notice | Capacities measured according to EN14511 | * Measured according to EN12102 | ** Lp at 5m in free field (Q=2) |
|