Startup
- Start-up by CAIROX BELGIUM is strongly recommended
Notes
The 3-way valve is not supplied with the CGW-M unit.
Technical data
|
Heating capacity A7/W35 | kW | 6,00 | 8,20 | 10,20 | 12,00 | 15,70 | 15,70 | COP A7/W35 | | 5,40 | 5,32 | 5,05 | 4,94 | 4,55 | 4,40 | Heating capacity A7/W45 | kW | 6,80 | 8,30 | 10,20 | 13,00 | 16,20 | 16,20 | COP A7/W45 | | 4,10 | 4,36 | 4,08 | 3,77 | 3,61 | 3,61 | Heating capacity A2/W35 | kW | 4,80 | 8,16 | 8,80 | 11,04 | 12,64 | 12,64 | COP A2/W35 | | 3,99 | 3,80 | 3,76 | 3,65 | 3,57 | 3,34 | Heating capacity A2/W45 | kW | 4,80 | 8,16 | 8,80 | 11,04 | 12,64 | 12,64 | COP A2/W45 | | 3,19 | 3,04 | 3,01 | 2,92 | 2,86 | 2,86 | Heating capacity A-7/W35 | kW | 3,96 | 7,26 | 7,79 | 9,11 | 10,43 | 10,43 | COP A-7/W35 | | 3,15 | 2,97 | 2,94 | 2,88 | 2,82 | 2,64 | Heating capacity A-7/W45 | kW | 3,96 | 7,26 | 7,79 | 9,11 | 10,43 | 10,43 | COP A-7/W45 | | 2,52 | 3,38 | 2,35 | 2,30 | 2,26 | 2,11 | Heating capacity A-10/W35 | kW | 3,60 | 6,60 | 7,08 | 8,28 | 9,48 | 9,48 | Heating capacity A-10/W45 | kW | 3,60 | 6,60 | 7,08 | 8,28 | 9,48 | 9,48 | Cooling capacity A35/W7 | kW | 5,70 | 7,40 | 9,00 | 11,10 | 13,80 | 13,80 | EER A35/W7 | | 3,25 | 3,70 | 3,40 | 3,10 | 2,71 | 2,71 | Cooling capacity A35/W18 | kW | 6,50 | 8,30 | 10,20 | 12,00 | 15,50 | 15,40 | EER A35/W18 | | 5,10 | 5,32 | 5,10 | 4,90 | 4,31 | 3,80 | SEER A35 | | 4,96 | 5,02 | 5,06 | 4,93 | 4,81 | 4,68 | SCOP W35/W55 | | 5,04/3,50 | 4,51/3,70 | 4,48/3,88 | 4,78/3,80 | 4,69/3,76 | 4,56/3,83 | Seasonal efficiency heat pump ηs W35/W55 | | 199/137 | 177/145 | 176/152 | 188/149 | 184/147 | 179/150 | Annual energy consumption heat pump W35/W55 | kWh | 2386/2882 | 3827/5206 | 4163/5486 | 5194/6387 | 6072/7675 | 5927/7404 | Energy class W35/W55 | | A+++/A++ | A+++/A++ | A+++/A+++ | A+++/A++ | A+++/A++ | A+++/A+++ | Refrigerant (GWP) | | R32 (675) | Refrigerant charge | gr (CO2eq-T) | 950 (0,64) | 1600 (1,08) | 1600 (1,08) | 2200 (1,49) | 2200 (1,49) | 2200 (1,49) | Power supply | V / Ph / Hz | 230/1/50 | 400/3/50 | Rated power | kW | 2.45 | 5,20 | 5.75 | 6.85 | 6,90 | 8.66 | Air flow rate | m³/h | 3200 | 5800 | 5800 | 5800 | 5015 | 5015 | Hydraulic connections (supply-return) | inch | 1" | Outgoing water temperature (min.-max.) | Heating | °C | 20 ~ 60 | Cooling | °C | 7 ~ 25 | DHW | °C | 40 ~ 80 | Components | Compressor | Type | - | DC Rotary | Absorbed power | W | 1230 | 2375 | 2375 | 3680 | 3680 | 3680 | Pump | Type | - | High-efficiency pump | Regulation | - | Electronic - continuous control | Capacity (min.-max.) | W | 3 ~ 87 | Flow rate (min.) | l/h | 720 | Expansion vessel | Volume* | l | 2 | 3 | Pre-pressure | bar | 1,50 | Electrical heating | Type | - | Wet | Material | - | Incoloy825 | Regulation | - | Automatic | Number of steps | - | 2 | Capacity | kW | 3 | 6 | Combination | kW | 1,50 + 1,50 | 3 + 3 | Heat exchanger | Type | - | Plate heat exchanger | Number | - | 1 | Sound power level** | dB | 58 | 68 | 68 | 68 | 68 | 68 | Sound pressure level @ 1m** | dB(A) | 53 | 54 | 54 | 56 | 59 | 59 | Sound pressure level @ 5m*** | dB(A) | 36 | 46 | 46 | 46 | 46 | 46 | Power cable section heat pump | mm² | 3G2,5 | 3G4 | 3G4 | 3G6 | 3G6 | 5G2,5 | Automatic fuse (slow) heat pump | A | 16 | 32 | 32 | 40 | 40 | 16 | Power cable section electrical heating | mm² | 3G2,5 | 3G6 | 3G6 | 3G6 | 3G6 | 5G2,5 | Automatic fuse (slow) electrical heating | A | 16 | 32 | 32 | 32 | 32 | 16 | Dimensions | Unit (LxDxH) | mm | 735x1150x365 | 878x1206x445 | Weight | kg | 95 | 127 | 127 | 142 | 142 | 148 | Specifications and design can be modified for further improvement without prior notice | Capacities measured according to EN14511 | * The size of the expansion vessel should be determined in accordance with the total water volume of the system | ** Measured according to EN12102 | *** Lp measured at 5m in free field (Q=2) |
|