PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

CGW-M SG • Air/water heat pumps R32 Monobloc

Air/water DC inverter-controlled monoblock heat pump with R32 refrigerant.

All hydraulic components such as a water pump, expansion vessel, pressure relief valve, back-up heater, etc., as well as the heat pump are combined in this monoblock. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for home heating and cooling and domestic hot water. The intelligent regulation of the compressor and the expansion valve ensures precise and fast water temperature control, thus reducing energy consumption.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Production of domestic hot water, provided a hot water heater is installed

Composition

  • High efficiency plate heat exchanger
  • Energy-efficient circulation pump
  • Colour touch screen controller (wired)

  • Expansion vessel (2 or 3 liters)
  • Safety valve (3 bar)
  • Electrical backup heater
  • Water pressure sensor
  • Integrated outside temperature sensor

  • DC inverter-controlled two-stage compressor with gas injection
  • DC fan motor
  • Gold Fin condenser

Refrigerant

  • R32

Specifications

  • Monobloc system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 55°C at outside temperatures down to -15°C
  • A+++ at 35°C water temperature
  • Bivalent setup
    • The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.

  • Smart Grid ready
  • Visual indication of energy consumption
  • Standard equipped with WiFi
  • Standard equipped with Modbus interface
  • Easy installation
  • EUROVENT EN 14511 and EN 14825 certification
  • Keymark certification

Accessories

  • Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Cascade module, type CASCADE
  • Buffer tank, type BTE 60, BTE 100
  • Anti-vibration mounting blocks, type MPRH
  • 3-way zone valve, type TWV
  • Antifreeze valve, type AFP
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Coding plug for permanently disabling the cooling function, type COD-M-H

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group, anti-freeze protection and expansion vessel MUST be provided on site.

Applicable boiler

  • Domestic hot water heater 200 liters, type SANI-EM 200
  • Domestic hot water heater 300 liters, type SANI-EM 300, SANI+ 300
  • Domestic hot water heater 500 liters, type SANI-EM 500, SANI+ 500

Artikelen

Artikelselectie-assistent
Type
L Gat [mm]
H Gat [mm]
Qv(2Pa) [m³/h]
Qv(10Pa) [m³/h]
Artikelnummer Type L Gat [mm] H Gat [mm] Qv(2Pa) [m³/h] Qv(10Pa) [m³/h] E-shop
E020530200100 GZ60+GZKF+GZKV 200 X 100 200 100 19.30 42.50
E020530200200 GZ60+GZKF+GZKV 200 X 200 200 200 48.30 112.50
E020530300100 GZ60+GZKF+GZKV 300 X 100 300 100 28.50 65.30
E020530300200 GZ60+GZKF+GZKV 300 X 200 300 200 67.50 175.10
E020530300300 GZ60+GZKF+GZKV 300 X 300 300 300 133 289.20
E020530400100 GZ60+GZKF+GZKV 400 X 100 400 100 39 88.20
E020530400200 GZ60+GZKF+GZKV 400 X 200 400 200 107.40 239.10
E020530400300 GZ60+GZKF+GZKV 400 X 300 400 300 192.20 397.70
E020530400400 GZ60+GZKF+GZKV 400 X 400 400 400 291.10 563.80
E020530500100 GZ60+GZKF+GZKV 500 X 100 500 100 47.80 111.40
E020530500200 GZ60+GZKF+GZKV 500 X 200 500 200 141 304.50
E020530500300 GZ60+GZKF+GZKV 500 X 300 500 300 258.40 509.70
E020530500400 GZ60+GZKF+GZKV 500 X 400 500 400 400.10 727
E020530600100 GZ60+GZKF+GZKV 600 X 100 600 100 58.10 134.70
E020530600200 GZ60+GZKF+GZKV 600 X 200 600 200 177.20 371.10
E020530600300 GZ60+GZKF+GZKV 600 X 300 600 300 331.70 625.20
E020530600400 GZ60+GZKF+GZKV 600 X 400 600 400 521.50 897
E020530700100 GZ60+GZKF+GZKV 700 X 100 700 100 86.70 158.20
E020530700200 GZ60+GZKF+GZKV 700 X 200 700 200 216.10 439.10
E020530700300 GZ60+GZKF+GZKV 700 X 300 700 300 412 744.30
E020530700400 GZ60+GZKF+GZKV 700 X 400 700 400 656 1073.30
E020530800100 GZ60+GZKF+GZKV 800 X 100 800 100 79.70 182
E020530800200 GZ60+GZKF+GZKV 800 X 200 800 200 257.70 508.50
E020530800300 GZ60+GZKF+GZKV 800 X 300 800 300 499.30 866.80
E020530800400 GZ60+GZKF+GZKV 800 X 400 800 400 804.80 1257.10
=> Voorraadproduct centraal magazijn behoudens verkoop
=> Voorraadproduct regionale filialen behoudens verkoop

Startup

  • Start-up by CAIROX BELGIUM is strongly recommended

Notes

The 3-way valve is not supplied with the CGW-M unit.

Technical data

Monobloc unitCGW-M SG 06 A1-1phCGW-M SG 08 A1-1phCGW-M SG 10 A1-1phCGW-M SG 12 A1-1phCGW-M SG 16 A1-1phCGW-M SG 16 M1-3ph
Heating capacity A7/W35kW6,008,2010,2012,0015,7015,70
COP A7/W35 5,405,325,054,944,554,40
Heating capacity A7/W45kW6,808,3010,2013,0016,2016,20
COP A7/W45 4,104,364,083,773,613,61
Heating capacity A2/W35kW4,808,168,8011,0412,6412,64
COP A2/W35 3,993,803,763,653,573,34
Heating capacity A2/W45kW4,808,168,8011,0412,6412,64
COP A2/W45 3,193,043,012,922,862,86
Heating capacity A-7/W35kW3,967,267,799,1110,4310,43
COP A-7/W35 3,152,972,942,882,822,64
Heating capacity A-7/W45kW3,967,267,799,1110,4310,43
COP A-7/W45 2,523,382,352,302,262,11
Heating capacity A-10/W35kW3,606,607,088,289,489,48
Heating capacity A-10/W45kW3,606,607,088,289,489,48
Cooling capacity A35/W7kW5,707,409,0011,1013,8013,80
EER A35/W7 3,253,703,403,102,712,71
Cooling capacity A35/W18kW6,508,3010,2012,0015,5015,40
EER A35/W18 5,105,325,104,904,313,80
SEER A35 4,965,025,064,934,814,68
SCOP W35/W55 5,04/3,504,51/3,704,48/3,884,78/3,804,69/3,764,56/3,83
Seasonal efficiency heat pump ηs W35/W55 199/137177/145176/152188/149184/147179/150
Annual energy consumption heat pump W35/W55kWh2386/28823827/52064163/54865194/63876072/76755927/7404
Energy class W35/W55 A+++/A++A+++/A++A+++/A+++A+++/A++A+++/A++A+++/A+++
Refrigerant (GWP) R32 (675)
Refrigerant chargegr (CO2eq-T)950 (0,64)1600 (1,08)1600 (1,08)2200 (1,49)2200 (1,49)2200 (1,49)
Power supplyV / Ph / Hz230/1/50400/3/50
Rated powerkW2.455,205.756.856,908.66
Air flow ratem³/h320058005800580050155015
Hydraulic connections (supply-return)inch1"
Outgoing water temperature (min.-max.)Heating°C20 ~ 60
Cooling°C7 ~ 25
DHW°C40 ~ 80
ComponentsCompressorType-DC Rotary
Absorbed powerW123023752375368036803680
PumpType-High-efficiency pump
Regulation-Electronic - continuous control
Capacity (min.-max.)W3 ~ 87
Flow rate (min.)l/h720
Expansion vesselVolume*l23
Pre-pressurebar1,50
Electrical heatingType-Wet
Material-Incoloy825
Regulation-Automatic
Number of steps-2
CapacitykW36
CombinationkW1,50 + 1,503 + 3
Heat exchangerType-Plate heat exchanger
Number-1
Sound power level**dB586868686868
Sound pressure level @ 1m**dB(A)535454565959
Sound pressure level @ 5m***dB(A)364646464646
Power cable section heat pumpmm²3G2,53G43G43G63G65G2,5
Automatic fuse (slow) heat pumpA163232404016
Power cable section electrical heatingmm²3G2,53G63G63G63G65G2,5
Automatic fuse (slow) electrical heatingA163232323216
DimensionsUnit (LxDxH)mm735x1150x365878x1206x445
Weightkg95127127142142148
Specifications and design can be modified for further improvement without prior notice
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured according to EN12102
*** Lp measured at 5m in free field (Q=2)
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be