PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

ARXB GALH • VRF compact duct models Fujitsu

  • Fujitsu
  • VRF Airstage
  • Duct type
  • Indoor unit
  • 2,2 - 5,6 kW
  • R410a

Brand

  • Fujitsu

Product

  • Indoor unit VRF JII-S/JII/VII/VRII, compact duct model

Application

  • Cooling or heating of smalle offices, living rooms, bedrooms, bathrooms, etc...
  • Ideal in hotel rooms horizontal as ceiling concealed, vertical as floor concealed or built-in closet.
  • For area's between 10 and 55 m2

Function

  • Air-Air Heatpump, Inverter type

Refrigerant

  • R410A

Features

  • Maximum installation flexibility, horizontal or vertical
  • Easy maintenance with external control box
  • Standard delivered with long life filters.
  • Compact design, 21,7 cm height
  • Three fan speeds (High/Medium/Low)
  • Interchangeable and removable air inlet, (bottom or front)
  • Adjustable statique pressure up to 50 Pa.
  • Two-direction drain piping
  • Moisture Removal
  • Automatic Air Flow Adjustment
  • Auto Restart
  • ON-/OFF-Timer (Wired Remote controller)
  • Weekly & Setback Timer
  • Connectable Distributing Duct
  • Built-in room thermo sensor in remote controller.
  • Child-lock function
  • Group control setting (One remote controller for several indoor units)
  • Dual remote controlling (Only possible with UTB-YPB)
  • EIB input - & output signal

Applicable outdoor units

  • Type AJYA 40/45/54 LALH
  • Type AJYA 72/90/108/126/144 LALH
  • Type AJY 40/45/54 LBLAH
  • Type AJY 072/090/108/126/144/162 LBLAH
  • Type AJY 40/45/54 LCLAH
  • Type AJY 40/45/54 LELAH
  • Type AJYA 72/90/108/126/144 GALH

Accessories

  • IR receiver unit.Type UTB-YWB (IR remote controller included)
  • Drain Up Kit. Type UTZ-PX1BBA
  • Remote sensor unit. Type UTD-RS100
  • Simple remote controller with master control. Type UTB-YPB
  • Simple remote controller without master control. Type UTB-YRA
  • External Switch Controller. Type UTR-YESA
  • EIB-input wire. Type EXTERNAL WIRE TYPE C
  • EIB-output wire. Type EXTERNAL WIRE TYPE B
  • Connector set for external input on electronic boads. Type UTD-ECS5A
  • Air outlet plenum box with 2xdia.200mm. Type UTD-BC18
  • Air inlet plenum box with short side filter acces with 2xdia.200mm. Type UTD-AFA18
  • Air inlet plenum box with long side filter acces with 2xdia.200mm. Type UTD-AFB18

Artikelen

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035530012010 UTV-10/L/2P 3.83 5.02 2 AC Vertical Left
J035530012020 UTV-20/L/2P 7.05 8.61 2 AC Vertical Left
J035530012030 UTV-30/L/2P 9.2 11.3 2 AC Vertical Left
J035530012040 UTV-40/L/2P 10.6 12.94 2 AC Vertical Left
J035530012050 UTV-50/L/2P 13.1 16.99 2 AC Vertical Left
J035530013010 UTV-10/R/2P 3.83 5.02 2 AC Vertical Right
J035530013020 UTV-20/R/2P 7.05 8.61 2 AC Vertical Right
J035530013030 UTV-30/R/2P 9.2 11.3 2 AC Vertical Right
J035530013040 UTV-40/R/2P 10.6 12.94 2 AC Vertical Right
J035530013050 UTV-50/R/2P 13.1 16.99 2 AC Vertical Right
J035530014110 UTV-10/L/4P 3.6 4.18 4 AC Vertical Left
J035530014120 UTV-20/L/4P 7.00 7.01 4 AC Vertical Left
J035530014130 UTV-30/L/4P 9.01 9.16 4 AC Vertical Left
J035530014140 UTV-40/L/4P 9.57 10.60 4 AC Vertical Left
J035530014150 UTV-50/L/4P 13.63 12.65 4 AC Vertical Left
J035530015010 UTV-10/R/4P 3.6 4.18 4 AC Vertical Right
J035530015020 UTV-20/R/4P 7.00 7.01 4 AC Vertical Right
J035530015030 UTV-30/R/4P 9.01 9.16 4 AC Vertical Right
J035530015040 UTV-40/R/4P 9.57 10.60 4 AC Vertical Right
J035530015050 UTV-50/R/4P 13.63 12.65 4 AC Vertical Right
J035530022010 UTC-10/L/2P 3.83 5.02 2 AC Horizontal Left
J035530022020 UTC-20/L/2P 7.05 8.61 2 AC Horizontal Left
J035530022030 UTC-30/L/2P 9.20 11.33 2 AC Horizontal Left
J035530022040 UTC-40/L/2P 10.60 12.94 2 AC Horizontal Left
J035530022050 UTC-50/L/2P 13.10 16.99 2 AC Horizontal Left
J035530023010 UTC-10/R/2P 3.83 5.02 2 AC Horizontal Right
J035530023020 UTC-20/R/2P 7.05 8.61 2 AC Horizontal Right
J035530023030 UTC-30/R/2P 9.20 11.33 2 AC Horizontal Right
J035530023040 UTC-40/R/2P 10.60 12.94 2 AC Horizontal Right
J035530023050 UTC-50/R/2P 13.10 16.99 2 AC Horizontal Right
J035530032010 UTC-10/L/4P 3.60 4.18 4 AC Horizontal Left
J035530032020 UTC-20/L/4P 7 7.01 4 AC Horizontal Left
J035530032030 UTC-30/L/4P 9.01 9.16 4 AC Horizontal Left
J035530032040 UTC-40/L/4P 9.57 10.60 4 AC Horizontal Left
J035530032050 UTC-50/L/4P 13.63 12.65 4 AC Horizontal Left
J035530033010 UTC-10/R/4P 3.60 4.18 4 AC Horizontal Right
J035530033020 UTC-20/R/4P 7 7.01 4 AC Horizontal Right
J035530033030 UTC-30/R/4P 9.01 9.16 4 AC Horizontal Right
J035530033040 UTC-40/R/4P 9.57 10.60 4 AC Horizontal Right
J035530033050 UTC-50/R/4P 13.63 12.65 4 AC Horizontal Right
*According to Eurovent at highest speed 0Pa
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...