PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

ERAS MC (VS) Kp • Air cooled chillers on propane

  • Chillers
  • Air/Water Cooling Only
  • EMICON
  • 54 - 353 kW
  • R290

Air-cooled propane chillers for the production of chilled water. The units are equipped with semi-hermetic reciprocating compressors. Inverter compressors on models 5210-10010. Axial 6-pole fans. Suitable for outdoor installation. Refrigerant R290 (GWP 3) (propane) These units are specially designed for cooling medium to large projects. Tandem technology offers multiple capacity stages and increases efficiency at part load. This also improves performance. Leak detector and ATEX certified fan in compartment with cooling circuit included as standard. Microchannel condenser coil. Mandatory commissioning by CAIROX.

Brand

  • Emicon

Application

  • Outdoor air/water chillers suitable for comfort and process cooling applications

Characteristics

  • Cooling capacity: 54 to 353 kW

Composition

  • Refrigerant gas R290 with a GWP of 3,3
  • Semi-hermetic reciprocating compressors
  • Power supply 400/3/50
  • Microprocessor controller
  • Leak detector included as standard
  • ATEX certified fan in compartment with cooling circuit
  • Microchannel condenser coil

Options

  • P1 Pump group with 1 pump
  • P2 Pump group with 2 pumps in parallel (1 running/1 standby)
  • partial heat recovery
  • Compressor Acoustic Enclosure
  • PA Rubber Vibration Dampers
  • PM Vibration dampers with springs
  • A+V Ampere and Voltmeter
  • BF Winter control down to -20°C
  • BT Winter control down to -10°C
  • CS Compressor inrush counter
  • MF Phase monitor
  • PQ Remote Control
  • PW Part-Winding (Lower Startup Current / Soft Start)
  • RF Improvement of cos phii >0.9
  • RL Compressor overload relay
  • EC EC fans
  • ECP Anti-corrosion coating on the condenser coils (Electro coating)
  • HRV2 High Pressure Double Safety Valve
  • PCP Anti-corrosion coating on the condenser coils (Powder coating)
  • RA Frost protection on evaporator (Electric heating with thermostat)
  • VSC Inverter control compressors
  • VSP Inverter control pump(s)
  • TE Electronic expansion valve
  • AXT Diffuser on the axial fans
  • GP Protective grille condenser
  • IH RS485 Serial Card
  • IH BAC BACNET RS485 Serial Card
  • IWG Interface => SNMP or TCP/IP or BACNET IP or MODBUS IP
  • I1 Insulation for around Victaulic flanges from pump to hydraulic lines
  • I2 Insulation for around Victaulic Flanges from Buffer Tank to Hydraulic Lines

Versions

  • ERAS.MC Kp
Standard version with Microchannel condenser coil
  • ERAS.MC VB Kp
Low water temperature version

Order example

ERAS 5210 MC (VS) Kp
Explanation
52 = Nominal cooling capacity (KW)
1 = Number of cooling circuits
MC = Microchannel condenser coil
VS = Inverter on compressor
Kp = Propane Refrigerant

Artikelen

Artikelselectie-assistent
Type
L Gat [mm]
H Gat [mm]
Qv(2Pa) [m³/h]
Qv(10Pa) [m³/h]
Artikelnummer Type L Gat [mm] H Gat [mm] Qv(2Pa) [m³/h] Qv(10Pa) [m³/h] E-shop
E020530200100 GZ60+GZKF+GZKV 200 X 100 200 100 19.30 42.50
E020530200200 GZ60+GZKF+GZKV 200 X 200 200 200 48.30 112.50
E020530300100 GZ60+GZKF+GZKV 300 X 100 300 100 28.50 65.30
E020530300200 GZ60+GZKF+GZKV 300 X 200 300 200 67.50 175.10
E020530300300 GZ60+GZKF+GZKV 300 X 300 300 300 133 289.20
E020530400100 GZ60+GZKF+GZKV 400 X 100 400 100 39 88.20
E020530400200 GZ60+GZKF+GZKV 400 X 200 400 200 107.40 239.10
E020530400300 GZ60+GZKF+GZKV 400 X 300 400 300 192.20 397.70
E020530400400 GZ60+GZKF+GZKV 400 X 400 400 400 291.10 563.80
E020530500100 GZ60+GZKF+GZKV 500 X 100 500 100 47.80 111.40
E020530500200 GZ60+GZKF+GZKV 500 X 200 500 200 141 304.50
E020530500300 GZ60+GZKF+GZKV 500 X 300 500 300 258.40 509.70
E020530500400 GZ60+GZKF+GZKV 500 X 400 500 400 400.10 727
E020530600100 GZ60+GZKF+GZKV 600 X 100 600 100 58.10 134.70
E020530600200 GZ60+GZKF+GZKV 600 X 200 600 200 177.20 371.10
E020530600300 GZ60+GZKF+GZKV 600 X 300 600 300 331.70 625.20
E020530600400 GZ60+GZKF+GZKV 600 X 400 600 400 521.50 897
E020530700100 GZ60+GZKF+GZKV 700 X 100 700 100 86.70 158.20
E020530700200 GZ60+GZKF+GZKV 700 X 200 700 200 216.10 439.10
E020530700300 GZ60+GZKF+GZKV 700 X 300 700 300 412 744.30
E020530700400 GZ60+GZKF+GZKV 700 X 400 700 400 656 1073.30
E020530800100 GZ60+GZKF+GZKV 800 X 100 800 100 79.70 182
E020530800200 GZ60+GZKF+GZKV 800 X 200 800 200 257.70 508.50
E020530800300 GZ60+GZKF+GZKV 800 X 300 800 300 499.30 866.80
E020530800400 GZ60+GZKF+GZKV 800 X 400 800 400 804.80 1257.10
=> Voorraadproduct centraal magazijn behoudens verkoop
=> Voorraadproduct regionale filialen behoudens verkoop

Specifications

ERAS MS(VS) Kp 521059107210871010010140201702021020240202902034020
Cooling capacitykW54.36174.792.9107156183216252289353
Total power inputkW16.419.223.329.234.247.556.468.376.9896.7114
SEER 4.174.124.244.174.14415241474.124.264.134.24
Refrigerant (GWP) R290 (3,3)
Precharged refrigerant chargekg(CO2eq-kg)4(13,2)4(13,2)7(23,1)7(23,1)8(26,4)14(46,2)14(46,2)16(52,8)16(52,8)15(49,5)20(66)
Water flowm³/h9.3410.5112.8615.9918.4326.7731.4737.1243.4249.7860.65
Water pressure dropkPa25.631.714.621.527.818.825.22329.522.732.4
Sound pressure leveldB(A)5456566060606363646467
Cooling capacity: Outdoor temperature 35°C - chilled water temperature in/out 12/7°C
Sound pressure level calculated according to ISO 3744 at 10 m distance from the unit

Dimensions

ERAS MC (VS) Kp 5210591072108710100101402017020210202402029020Z34020
L[mm]25902590259025904740484048404840484048404430
W[mm]13701370137013701370137013701370137013701370
H[mm]25702570257024202570257025702570257025702480
Gewicht/Poids[kg]10941096120613041310200220982156252225983100

Prices

Detailed selection / quotation available on request

Operational limits
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...