PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

EPAS MS (VS) Kp • Reversible heatpumps air/water on propane

  • Chillers and Heatpumps
  • Air/Water Heatpump
  • EMICON
  • 91 -295 kW 106 -344 kW
  • R290
  • EUROVENT

Reversible heatpump Air/Water on propane for the production of chilled/hot water. The units are equipped with semi-hermetic reciprocating compressors. Inverter compressors on models 10010-21020. Axial 6-pole fans. Suitable for outdoor installation. Refrigerant R290 (GWP 3) (propane) These units are specially designed for cooling medium to large projects. Tandem technology offers multiple capacity stages and increases efficiency at part load. This also improves performance. Leak detector and ATEX certified fan in compartment with cooling circuit included as standard. Mandatory commissioning by CAIROX.

Brand

  • Emicon

Application

  • Outdoor air/water reversible heatpumps suitable for comfort and process cooling and heating applications

Characteristics

  • Cooling capacity: 91 to 295 kW
  • Heating capacity:106 to 344 kW

Composition

  • Refrigerant gas R290 with a GWP of 3,3
  • Semi-hermetic reciprocating compressors
  • Power supply 400/3/50
  • Microprocessor controller
  • Leak detector included as standard
  • ATEX certified fan in compartment with cooling circuit
  • Copper/Aluminium battery with Bluefin coating

Options

  • RM Prepainted coating on the fins
  • RR copper/copper battery
  • PA Rubber Vibration Dampers
  • PM Vibration dampers with springs
  • BF Winter control down to -20°C
  • MF Phase monitor
  • PQ Remote Control
  • RF Improvement of cos phi >0.9
  • RA Frost protection on evaporator (Electric heating with thermostat)
  • VSC Inverter control compressors Soundproofing cladding around the compressors
  • PW Part-Winding (Lower Startup Current / Soft Start)
  • IWG Interface => SNMP or TCP/IP or BACNET IP or MODBUS IP
  • P1 Pump group with 1 pump
  • P2 Pump group with 2 pumps in parallel (1 running/1 standby) partial heat recovery
  • A+V Ampere and Voltmeter BT Winter control down to -10°C
  • CS Compressor inrush counter
  • RL Compressor overload relay
  • EC EC fans ECP Anti-corrosion coating on the air batteries (Electro coating)
  • HRV2 High Pressure Double Safety Valve
  • VSP Inverter control pump(s)
  • AXT Diffuser on the axial fans
  • GP Protective grille condenser
  • IH RS485 Serial Card
  • IH BAC BACNET RS485 Serial Card
  • I1 Insulation for around Victaulic flanges from pump to hydraulic lines
  • I2 Insulation for around Victaulic Flanges from Buffer Tank to Hydraulic Lines

Versions

  • EPAS. Kp
Standard version with Blue Fin coating on coil
  • EPAS. VB Kp
Low water temperature version with Blue Fin coating on coil

Order example

EPAS 10010 (VS) Kp
Explanation
100 = Nominal cooling capacity (KW)
1 = Number of cooling circuits
VS = Inverter on compressor
Kp = Propane Refrigerant

Artikelen

Artikelselectie-assistent
Type
Lengte [mm]
Kleur
Spleten
Artikelnummer Type Lengte [mm] Kleur Spleten E-shop
A04630C100800 ASR-1 L=800 MM (RAL9016) 800 RAL9016 1
A04630C100A00 ASR-1 L=1000 MM (RAL9016) 1000 RAL9016 1
A04630C100F00 ASR-1 L=1500 MM (RAL9016) 1500 RAL9016 1
A04630C100K00 ASR-1 L=2000 MM (RAL9016) 2000 RAL9016 1
A04630C200800 ASR-2 L=800 MM (RAL9016) 800 RAL9016 2
A04630C200A00 ASR-2 L=1000 MM (RAL9016) 1000 RAL9016 2
A04630C200F00 ASR-2 L=1500 MM (RAL9016) 1500 RAL9016 2
A04630C200K00 ASR-2 L=2000 MM (RAL9016) 2000 RAL9016 2
A04630C300800 ASR-3 L=800 MM (RAL9016) 800 RAL9016 3
A04630C300A00 ASR-3 L=1000 MM (RAL9016) 1000 RAL9016 3
A04630C300F00 ASR-3 L=1500 MM (RAL9016) 1500 RAL9016 3
A04630C300K00 ASR-3 L=2000 MM (RAL9016) 2000 RAL9016 3
A04630C400800 ASR-4 L=800 MM (RAL9016) 800 RAL9016 4
A04630C400A00 ASR-4 L=1000 MM (RAL9016) 1000 RAL9016 4
A04630C400F00 ASR-4 L=1500 MM (RAL9016) 1500 RAL9016 4
A04630C400K00 ASR-4 L=2000 MM (RAL9016) 2000 RAL9016 4
A04630F100800 ASR-1 L=800 MM 800 Aluminium 1
A04630F100A00 ASR-1 L=1000 MM 1000 Aluminium 1
A04630F100F00 ASR-1 L=1500 MM 1500 Aluminium 1
A04630F100K00 ASR-1 L=2000 MM 2000 Aluminium 1
A04630F200800 ASR-2 L=800 MM 800 Aluminium 2
A04630F200A00 ASR-2 L=1000 MM 1000 Aluminium 2
A04630F200F00 ASR-2 L=1500 MM 1500 Aluminium 2
A04630F200K00 ASR-2 L=2000 MM 2000 Aluminium 2
A04630F300800 ASR-3 L=800 MM 800 Aluminium 3
A04630F300A00 ASR-3 L=1000 MM 1000 Aluminium 3
A04630F300F00 ASR-3 L=1500 MM 1500 Aluminium 3
A04630F300K00 ASR-3 L=2000 MM 2000 Aluminium 3
A04630F400800 ASR-4 L=800 MM 800 Aluminium 4
A04630F400A00 ASR-4 L=1000 MM 1000 Aluminium 4
A04630F400F00 ASR-4 L=1500 MM 1500 Aluminium 4
A04630F400K00 ASR-4 L=2000 MM 2000 Aluminium 4

Specifications

EPAS (VS) Kp 1001012010150201702021020250202902034020
Cooling capacitykW90.7104129148180208247295
Total power input CoolingkW29.435.439.947.358.670.778.195.9
Water flowm³/h15.6117.9722.1725.4630.9135.7642.4950.75
Water pressure dropkPa20.526.413.517.224.421.829.523.6
Heating capacitykW106123148173214247289344
Total power input HeatingkW25.530.13441.251.758.367.284.3
SCOP 3.453.353.33.263.283.293.383.27
Refrigerant type (GWP) R290 (3.3)
Precharged refrigerant chargekg(CO2eq-kg)17(0.0561)17(0.0561)19(0.0627)26(0.0858)33(0.1089)33(0.1089)41(0.1353)51(0.1683)
Water flowm³/h18.3321.2325.529.9137.0442.6950.1859.42
Water pressure dropkPa2633.916.922.633.428.738.430.7
Sound pressure leveldB(A)6161616063636363
Cooling capacity: Outdoor temperature 35°C - chilled water temperature in/out 7/12°C
Heating capacity: Outdoor temperature 7°C - water temperature in/out 30/35°C
Sound pressure level calculated according to ISO 3744 at 10 m distance from the unit

Dimensions

EPAS (VS) Kp 1001012010150201702021020250202902034020
L[mm]26602660370025904740484048405890
W[mm]13701370137013701370137013701370
H[mm]24202420242025702420242025702420
Gewicht/Poids[kg]14161466179813041310236620983106

Prices

Detailed selection / quotation available on request

Operational limits
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be