KG5/KG10-Kp (PAE GPE) • Gateway framework kit for communication between up to 5 or 10 units in cascade

  • Heatpumps
  • Air/water monoblock
  • Emicon
  • Accessories for modular units
  • Communication card for cascaded units

When multiple EVEREST 290 units are cascaded, the individual units must communicate with each other. For this purpose, a gateway panel must be used (KG5-Kp (PAE GPE) kit if the system consists of 2 to 5 units or KG10-Kp (PAE GPE) kit if the system consists of 6 to 10 units) to which each unit must be connected via a data cable of the RJ45 ETHERNET type.

Brand

  • Emicon

Application

  • Can only be ordered as an option when purchasing EVEREST 290 units in cascade
  • KG5-Kp (PAE GPE) for communication between 2 to 5 EVEREST units in cascade
  • KG10-Kp (PAE GPE) for communication between 6 to 10 EVEREST units in cascade
  • You only need 1 kit per cascade

Characteristics

  • Gateway communication kit for 2 to 5 units (KG5-Kp (PAE GPE)) or 6 to 10 units (KG10-Kp (PAE GPE) in cascade: Card for creating a data communication network between multiple modular EVEREST units in cascade. A space is provided on the back of the front panel of each EVEREST unit to mount the closed board containing this card (supplied as a kit).
  • It is advisable to install the KG5-Kp (PAE GPE) or KG10-Kp (PAE GPE) kit on one of the two units on the outside of the modular system. In this case, removing one of the units from the system does not mean that the network cables of the other units have to be re-laid.
  • The supply and installation of the cables for data transmission is the responsibility of the installer.
  • The data cable to be used must be suitable for external installations, UV-resistant and in any case suitable for the environmental conditions expected at the installation site.
  • A non-inverting Ethernet cable of at least category 6 is recommended.
  • The data cables must be physically separated from the power cables. It is necessary to create a special pipeline to avoid failures due to electromagnetic interference.

Composition

  • KG5-Kp (PAE GPE) Closed board with built-in gateway panel that provides the communication between 2 to 5 units in cascade
  • KG10-Kp (PAE GPE) Closed board with built-in gateway panel that provides the communication between 6 to 10 units in cascade

Versions

  • KG5-Kp (PAE GPE)
  • KG10-Kp (PAE GPE)

Artikelen

Artikelselectie-assistent
Type
Koelvermogen* [kW]
Verwarmingsvermogen* [kW]
Wateraansluiting
Artikelnummer Type Koelvermogen* [kW] Verwarmingsvermogen* [kW] Wateraansluiting E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Links
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Links
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Links
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Links
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Links
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Links
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Rechts
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Rechts
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Rechts
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Rechts
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Rechts
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Rechts
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Links
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Links
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Links
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Links
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Links
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Links
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Rechts
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Rechts
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Rechts
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Rechts
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Rechts
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Rechts
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Links
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Links
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Links
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Links
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Links
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Links
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Rechts
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Rechts
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Rechts
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Rechts
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Rechts
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Rechts
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Links
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Links
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Links
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Links
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Links
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Links
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Rechts
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Rechts
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Rechts
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Rechts
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Rechts
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Rechts
* (Koeling) Binnen temp.: 27°C ruimtetemp. - Waterregime.: 7°C ingaand /12°C uitgaand op middensnelheid (Verwarming) Binnen temp.: 20°C - Waterregime.: 45°C ingaand /40°C Uitgaand op middensnelheid.