KG5/KG10-Kp (PAE GPE) • Gateway framework kit for communication between up to 5 or 10 units in cascade

  • Heatpumps
  • Air/water monoblock
  • Emicon
  • Accessories for modular units
  • Communication card for cascaded units

When multiple EVEREST 290 units are cascaded, the individual units must communicate with each other. For this purpose, a gateway panel must be used (KG5-Kp (PAE GPE) kit if the system consists of 2 to 5 units or KG10-Kp (PAE GPE) kit if the system consists of 6 to 10 units) to which each unit must be connected via a data cable of the RJ45 ETHERNET type.

Brand

  • Emicon

Application

  • Can only be ordered as an option when purchasing EVEREST 290 units in cascade
  • KG5-Kp (PAE GPE) for communication between 2 to 5 EVEREST units in cascade
  • KG10-Kp (PAE GPE) for communication between 6 to 10 EVEREST units in cascade
  • You only need 1 kit per cascade

Characteristics

  • Gateway communication kit for 2 to 5 units (KG5-Kp (PAE GPE)) or 6 to 10 units (KG10-Kp (PAE GPE) in cascade: Card for creating a data communication network between multiple modular EVEREST units in cascade. A space is provided on the back of the front panel of each EVEREST unit to mount the closed board containing this card (supplied as a kit).
  • It is advisable to install the KG5-Kp (PAE GPE) or KG10-Kp (PAE GPE) kit on one of the two units on the outside of the modular system. In this case, removing one of the units from the system does not mean that the network cables of the other units have to be re-laid.
  • The supply and installation of the cables for data transmission is the responsibility of the installer.
  • The data cable to be used must be suitable for external installations, UV-resistant and in any case suitable for the environmental conditions expected at the installation site.
  • A non-inverting Ethernet cable of at least category 6 is recommended.
  • The data cables must be physically separated from the power cables. It is necessary to create a special pipeline to avoid failures due to electromagnetic interference.

Composition

  • KG5-Kp (PAE GPE) Closed board with built-in gateway panel that provides the communication between 2 to 5 units in cascade
  • KG10-Kp (PAE GPE) Closed board with built-in gateway panel that provides the communication between 6 to 10 units in cascade

Versions

  • KG5-Kp (PAE GPE)
  • KG10-Kp (PAE GPE)

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right