PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

GALILEO-ECM • Design fancoil units for wall mounting

Compact fan coil units, for wall mounting under the ceiling, for cooling or heating (2 pipes). The GALILEO-ECM is equipped with an EC motor with whisper-quiet operation and intelligent airflow control. This ensures high comfort at any ventilation speed.

Brand

  • Ventilclima

Application

  • Compact design fancoil units (thickness 185 mm) with 2 pipes for cooling OR heating of homes, hotels, shops, offices,...

Characteristics

  • Design fancoil unit with compact dimensions and quiet operation
  • Standard color white RAL9010, RAL of your choice according to price on request
  • 4 different sizes
  • Always 2-pipe
  • Only available with left hydraulic connections
  • Model NC-MAL has a manual louver and can be combined with the Ventilclima wall thermostats i-Basic 3, i-Digit 3, i-30 or i-70 (thermostat in option).
  • Model RC-MOL has a motherboard, a motorized louver and can be combined with the Ventilclima wall thermostat RWI-ECM2 (thermostat in option).
  • Model RC-MOL-IR has a motherboard, a motorized louver, a supplied remote control and could also be combined with the Ventilclima wall thermostat RWI-ECM2 (thermostat in option, choice of IR or wired control via DIP switch).
  • Suffix -2WV or -3WV indicates a built-in 2- or 3-way valve.

Composition

  • New modern and elegant design for high wall mounting
  • Copper tube battery with aluminium fins attached to the tubes by mechanical expansion of the copper tube in the opening of the aluminium fins. Brass manifolds with Ø 1/2" female gas connections and easily accessible manual air vents.

  • Tangential fans, aluminum rotors, statically and dynamically balanced
  • Air filter

  • Only 2 pipes

  • Low noise level

  • Limited thickness (185 mm)

  • 4 sizes

  • EC motor

  • Available in different colours (available on request)

  • Also available with AC motor

Versions

  • Standard color white RAL9010, RAL of your choice according to price on request

Accessories

  • 2 or 3-way valves (ON/OFF 230Vac) mounted on models with -2WV and -3WV addition
  • Available on request: 2- or 3-Way valves (ON/OFF 24Vac or 0-10V MODULATING 24Vac)
  • Condensate pump (mounted) GALILEO-CP-M
  • Wall control RWI-ECM2 for ECM-RC-MOL with motorized louvers to be ordered separately
  • Wall control I-Basic 3 I-Digit Zero 1-2-3, I30-I70 for ECM-NC-MAL with manual flaps to be ordered separately
  • Pre-assembly box GALILEO-P-INST-BOX

Order example

GALILEO-ECM-1-RC-MOL-IR-2WV

Explanation

GALILEO= Fan coil unit for wall mounting under the ceiling

ECM = EC motor

1 = size, see table

RC-MOL-IR = with motherboard, motorised louver and supplied with IR remote control

2WV = 2 way valve (mounted), 3WV = 3 way valve (mounted)

Text for tender

Kopiëren
Fan coil units for wall mounting under the ceiling, 230V or 24V, manually adjustable or motorized flaps, 2 or 3 way valves, tangential fans, elegant and modern housing design, available in serveral colours on request.

Articles

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] Hydraulic connection E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Left
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Left
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Left
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Left
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Left
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Left
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Right
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Right
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Right
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Right
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Right
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Right
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Left
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Left
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Left
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Left
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Left
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Left
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Right
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Right
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Right
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Right
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Right
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Right
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Left
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Left
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Left
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Left
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Left
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Left
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Right
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Right
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Right
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Right
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Right
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Right
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Left
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Left
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Left
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Left
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Left
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Left
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Right
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Right
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Right
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Right
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Right
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Right
Prices right version = prices left version

Specifications

TypeCooling capacity*Heating capacity*Airflow*Sound pressure**
 (7/12°C) kW(45/40°C) kWm3/hdB(A)
GALILEO 11.92.2825025
GALILEO 22.252.8837028
GALILEO 33.033.2347027
GALILEO 43.84.478030
* Room temperature 27°C (DB) / 19°C (WB) - cooling
* Room temperature 20°C (DB) - heating
* Values are measured at highest speed

**Sound pressure (Lp), room 90m³, reflection 0,5 sec, at lowest speed
Sound power (Lw) +- 8,6 dB(A) higher than sound pressure (Lp)

Dimensions

 1
2
3
4
L [mm]
930
930
1235
1235
M [mm]850
850
1155
1155
H [mm]
323
323
323
323
H1 [mm]
333
333
333
333
P [mm]
185
185
185
185
[kg]
12.5
12,5
16
16
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be