PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

LIGHT-600x600 • Cassette units 600 x 600 mm AC motors

EUROVENT certified fan coil; cassette unit for ceiling mounting 600 x 600 mm, for cooling and/or heating of water

Brand

  • Ventilclima

Application

  • For cooling and/or heating by water of hotels, hospitals, shops, offices,...

Composition

  • Galvanised steel, with thermo-acoustic isolation
  • Hooks in corners for easy mounting in ceiling
  • Condensate pump (Prevalence is 650 mm)
  • One phase electrical motor with overload cutout, 3 speeds
  • Air filter is attached on the inside of the louvre
  • The exchagers are made of copper tubes with female fittings
  • Also available ECM model with EC motor

Options

Louvre/valves/controller have to be ordered seperately
  • 2-pipe (LIGHT 6x) or 4-pipe (LIGHT 8x)
  • With infrared controller or wall mounted controller
  • Premounted internal valves
  • Electrical resistance (E)
  • Input of fresh air
  • ON/OFF or modulating motor 230 or 24V on the valves
  • Eurovent certificated hygiene units available on demand
  • Also available ECM model with EC motor

Accessories

  • Decoration panel, type LIGHT-PANEL-600x600: to be ordered separately!
    • In metal (MET) or plastic (ABS)
    • Manual (M), motorized (A) or fixed (F) louvers
    • Thermostat (NC) or infrared controller (RC)
    • Thermostat, type I-10 / I-20/ I-50 / I-60 / I-70 (to be ordered separately)
  • Infrared controller, type LIGHT-IR
  • Auxiliary drain pan always supplied included (not installed)

  • The decorative panel must be ordered separately

Order example

LIGHT-ECM-63-RC-E

Explication

LIGHT-ECM = Cassette with EC motor

63 = Size

RC = With infrared controller

NC = Wall thermostat

E = Electric resistance

(83C and 84C have more cooling capacity than 83 and 84 due to more efficient battery)

Articles

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] Hydraulic connection E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Left
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Left
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Left
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Left
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Left
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Left
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Right
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Right
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Right
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Right
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Right
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Right
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Left
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Left
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Left
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Left
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Left
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Left
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Right
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Right
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Right
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Right
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Right
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Right
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Left
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Left
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Left
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Left
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Left
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Left
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Right
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Right
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Right
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Right
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Right
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Right
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Left
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Left
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Left
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Left
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Left
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Left
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Right
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Right
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Right
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Right
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Right
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Right
Prices right version = prices left version

Specifications

LIGHT-600 x 600 - 2 pipes (LIGHT 6x)
   6162636465
Cooling capacity 7/12°C *[W]max22232667424749755381
[W]med18352433304736484655
[W]min15561944214426973967
Water flow[l/h]max390465739867939
[l/h]med321424530635812
[l/h]min271338372468691
Water pressure drop[kPa]max2016242430
[kPa]med1414181824
[kPa]min1110111618
Heating capacity 45/40°C *[W]max23402620408049105420
[W]med19202370293034404930
[W]min15901910209025804090
Water pressure drop[kPa]max20.915.518.522.829.6
[kPa]med14.212.516.21825.7
[kPa]min10.58.99.715.319.2
Heating capacity 50°C *[W]max28003150491059006500
[W]med23002850352241505900
[W]min19002300251031004900
Water pressure drop[kPa]max19161923,129
[kPa]med13131719,823
[kPa]min1091016,518
Sound power level[dB(A)]max4644526062
[dB(A)]med3941444959
[dB(A)]min3334343956
Sound pressure level[dB(A)]max3735435153
[dB(A)]med3032354050
[dB(A)]min2425253047
Air flow[m³/h]max367398550660760
[m³/h]med295355398468660
[m³/h]min225269269328550
Net weight[kg]net2021232324
Asynchronous motor
Motor fan absorbed power[W]max4843637589
Motor fan absorbed current[A]max0,220,190,280,330,39
EC-motor (LIGHT-ECM)
Motor fan absorbed power[W]max1211,225,54058
Motor fan absorbed current[A]max0,110,110,220,330,47
Electrical heating (LIGHT-E)
Heating power output[W] 15001500250025002500
Heating power input[V] 230230230230230
* The cooling capacity/ heating capaity are realised under the following EUROVENT conditions
(Cooling) Temp. Int.: 27°C D.B./19°C W.B. – Water: 7°Cin /12°C out
(Heating) Temp. Int: 20°C D.B. – Water : 45°C in /40°C out
(Heating) Temp. Int: 20°C D.B. – Water : 50°C in
The sound power level test has been performed according to EN 16583:2015 standard (n.a. = Non available)

Specifications

LIGHT-600 x 600 - 4 pipes (LIGHT 8x)
   81828383C8484C
Cooling capacity*[W]max230327073337382738254395
[W]med190523732507295730483408
[W]min160618641884197423672627
Water flow[l/h]max403472584668669767
[l/h]med333414438515532594
[l/h]min280324328343412456
Water pressure drop[kPa]max18141732.32128
[kPa]med151214281722
[kPa]min101010221217
Heating capacity*[W]max269030703900289043803250
[W]med230026803070234035102610
[W]min178021502150168027602100
Water pressure drop[kPa]max122043184121
[kPa]med111635153519
[kPa]min91221112213
Sound power level[dB(A)]max464752525858
[dB(A)]med394144444951
[dB(A)]min333734373944
Sound pressure level[dB(A)]max373843434949
[dB(A)]med303235354042
[dB(A)]min242825283035
Air flow[m³/h]max367398550550660660
[m³/h]med295355398398468468
[m³/h]min224269269269328328
Net weight[kg]net232424242424
Asynchronous motor
Motor fan absorbed power[W]max474363637575
Motor fan absorbed current[A]max0,220,190.280.280.330.33
EC-motor (LIGHT-ECM)
Motor fan absorbed power[W]max121225293844
Motor fan absorbed current[A]max0.160.160.280.310.360.42
Moteur EC (LIGHT-ECM)
Heating power output[W] n.a.n.a.n.a.n.a.n.a.n.a.
Heating power input[V] n.a.n.a.n.a.n.a.n.a.n.a.
* The cooling capacity/ heating capaity are realised under the following EUROVENT conditions 
(Cooling) Temp. Int.: 27°C D.B./19°C W.B. – Water: 7°Cin /12°C out 
(Heating) Temp. Int: 20°C D.B. – Water : 65°C in /55°C out 
The sound power level test has been performed according to EN 16583:2015 standard (n.a. = Non available) 

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...