The slim
condensate pump Pumpkin10 with a separate 2-stage detection block is very
convenient for installation in a mounting duct thanks to its small dimensions.
The 2-stage detection block switches the pump on/off.
Brand
Eckerle
Application
Split units up to 10 kW
Composition
The condensate pump with vibration dampers
A detection block
A PVC vent hose
2x double sided padded tape
A silicone hose (Ø15 mm, lenght 40mm) connected to the drain hose
Specifications
The pump can be placed horizontally and vertically. The float switch must be placed horizontal.
Max. flow rate: 9 l/h
Max. delivery height: 10 m
Max. suction height: 1,5 m
Sound level at 1m: 23 dB(A) (according to EN ISO 3744)
Mounting
Directly on the drainage hose
On the drainage of the condensate tray
Artikelen
Artikelselectie-assistent
Type
Diameter [mm]
Type
Spanning [V]
Artikelnummer
Type
Diameter [mm]
Type
Spanning [V]
E-shop
I050201110440
HF D 110-17D 400V 1400t/min
110
17D
3 x 400
I050201160440
HF D 160-17D 400V 1400t/min
160
17D
3 x 400
I050201200440
HF D 200-17D 400V 1400t/min
200
17D
3 x 400
I050201250440
HF D 250-15D 400V 1400t/min
250
15D
3 x 400
I050201315440
HF D 315-15D 400V 1400t/min
315
15D
3 x 400
Dimensions
Pump (L x W x H) : 165 x 33 x 33 mm
Detection block (L x W x D): 82 x 39 x 39 mm
Dimensions
Accessoires
Anti-return valve, type ACC-CV
Condensate drain
hose 6 mm, type Kristal 6/9 (L= 50 m)
Connection piece 6mm (set of 10 pcs), type ACC-CON6
Electrical extension cable 3 m, type ACC-CBL3
Electrical extension cable 5m, type ACC-CBL5
Replacement detection block, type ACC-FS
Technical data
Supply voltage: 230 V AC
Power consumption: 15 W (operation) and 1 W (standby)