This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
The slim
condensate pump Pumpkin10 with a separate 2-stage detection block is very
convenient for installation in a mounting duct thanks to its small dimensions.
The 2-stage detection block switches the pump on/off.
Brand
Eckerle
Application
Split units up to 10 kW
Composition
The condensate pump with vibration dampers
A detection block
A PVC vent hose
2x double sided padded tape
A silicone hose (Ø15 mm, lenght 40mm) connected to the drain hose
Specifications
The pump can be placed horizontally and vertically. The float switch must be placed horizontal.
Max. flow rate: 9 l/h
Max. delivery height: 10 m
Max. suction height: 1,5 m
Sound level at 1m: 23 dB(A) (according to EN ISO 3744)
Mounting
Directly on the drainage hose
On the drainage of the condensate tray
Dimensions
Pump (L x W x H) : 165 x 33 x 33 mm
Detection block (L x W x D): 82 x 39 x 39 mm
Dimensions
Accessoires
Anti-return valve, type ACC-CV
Condensate drain
hose 6 mm, type Kristal 6/9 (L= 50 m)
Connection piece 6mm (set of 10 pcs), type ACC-CON6
Electrical extension cable 3 m, type ACC-CBL3
Electrical extension cable 5m, type ACC-CBL5
Replacement detection block, type ACC-FS
Technical data
Supply voltage: 230 V AC
Power consumption: 15 W (operation) and 1 W (standby)