The cleaner (C3 Cleaner 570911) dislodges sludge, scale deposits and dirt particles from hydraulic installations, after which the filter or dirt separator collects the dirt so that it can be eliminated. The cleaner can be applied to new and existing heating and cooling systems at high or low temperature. The cleaner is non-aggressive and therefore suitable for all materials used in hydraulic systems. In addition, the cleaner can be used with all types of propylene glycol.

Brand

Caleffi

Application

To remove sludge, scale, dirt particles and deposits from existing installations. For new installations, the cleaner enables commissioning to the required standards.

Specifications

  • Bottle content: 500 ml liquid
  • Colour: light brown
  • Odour: light
  • pH: 7-8
  • Relative density: 1,15
  • Solubility (in water): soluble in hot and cold water

Artikelen

Artikelselectie-assistent
Type
Lengte [mm]
Kleur
Spleten
Artikelnummer Type Lengte [mm] Kleur Spleten E-shop
A04630C100800 ASR-1 L=800 MM (RAL9016) 800 RAL9016 1
A04630C100A00 ASR-1 L=1000 MM (RAL9016) 1000 RAL9016 1
A04630C100F00 ASR-1 L=1500 MM (RAL9016) 1500 RAL9016 1
A04630C100K00 ASR-1 L=2000 MM (RAL9016) 2000 RAL9016 1
A04630C200800 ASR-2 L=800 MM (RAL9016) 800 RAL9016 2
A04630C200A00 ASR-2 L=1000 MM (RAL9016) 1000 RAL9016 2
A04630C200F00 ASR-2 L=1500 MM (RAL9016) 1500 RAL9016 2
A04630C200K00 ASR-2 L=2000 MM (RAL9016) 2000 RAL9016 2
A04630C300800 ASR-3 L=800 MM (RAL9016) 800 RAL9016 3
A04630C300A00 ASR-3 L=1000 MM (RAL9016) 1000 RAL9016 3
A04630C300F00 ASR-3 L=1500 MM (RAL9016) 1500 RAL9016 3
A04630C300K00 ASR-3 L=2000 MM (RAL9016) 2000 RAL9016 3
A04630C400800 ASR-4 L=800 MM (RAL9016) 800 RAL9016 4
A04630C400A00 ASR-4 L=1000 MM (RAL9016) 1000 RAL9016 4
A04630C400F00 ASR-4 L=1500 MM (RAL9016) 1500 RAL9016 4
A04630C400K00 ASR-4 L=2000 MM (RAL9016) 2000 RAL9016 4
A04630F100800 ASR-1 L=800 MM 800 Aluminium 1
A04630F100A00 ASR-1 L=1000 MM 1000 Aluminium 1
A04630F100F00 ASR-1 L=1500 MM 1500 Aluminium 1
A04630F100K00 ASR-1 L=2000 MM 2000 Aluminium 1
A04630F200800 ASR-2 L=800 MM 800 Aluminium 2
A04630F200A00 ASR-2 L=1000 MM 1000 Aluminium 2
A04630F200F00 ASR-2 L=1500 MM 1500 Aluminium 2
A04630F200K00 ASR-2 L=2000 MM 2000 Aluminium 2
A04630F300800 ASR-3 L=800 MM 800 Aluminium 3
A04630F300A00 ASR-3 L=1000 MM 1000 Aluminium 3
A04630F300F00 ASR-3 L=1500 MM 1500 Aluminium 3
A04630F300K00 ASR-3 L=2000 MM 2000 Aluminium 3
A04630F400800 ASR-4 L=800 MM 800 Aluminium 4
A04630F400A00 ASR-4 L=1000 MM 1000 Aluminium 4
A04630F400F00 ASR-4 L=1500 MM 1500 Aluminium 4
A04630F400K00 ASR-4 L=2000 MM 2000 Aluminium 4

Notes


Flushing an existing or new installation:

  1. Turn off the circulation pump.

  2. Add the appropriate amount of cleaner to the installation, this can be done through the dirt separator. Overdosage poses no problems.
    Dosage: 500 ml per 150 l of water.

  3. Turn the circulation pump on and let the water circulate during:
    min. 1 hour for high temperature water (T > 50°C)
    min. 4 hours for low temperature water (30°C < T < 40°C)
    up to 1 week for cold water

  4. Turn off the circulation pump.

  5. Drain the water and flush thoroughly, at least twice, until the water runs clear. Dispose of drain water according to applicable regulations. Repeat the above steps for heavily contaminated systems.

  6. Add the appropriate amount of protection additive to the system.
    Dosage: 500 ml per 150 l of water.

  7. Turn the circulation pump on.

The complete instructions can be found in the manual under “Downloads”.