PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

PSG • Safety groups

  • Hydraulic accessories
  • Safety groups

Safety group (SFR 1852550) with shut-off valve and check valve for hot water installations to protect the water heater. According to current legislation it is mandatory to install a safety group for each appliance that heats water.

Brand

Watts

Installation

The safety group should be connected directly to the cold water inlet of the hot water heater. The outlet side of the group should face down and should be connected to the drain pipe through the siphon (SSG). To prevent leaks from the safety group due to expansion when the water heats up, an expansion vessel should be installed. If the pressure of the water at the inlet exceeds 3 bar, it is advisable to install a pressure regulator (PRV).

The complete installation and commissioning instructions can be found in the manual under “Downloads”.

Function

  • To protect the hot water storage heater from pressure excess: As the water temperature increases, the pressure also increases inside the hot water storage heater (dilation of the water).
  • To isolate the hot water storage heater from the cold water supply: This function is carried out by the shut-off valve (also part of the safety group).
  • To prevent a backflow of hot water into the cold water piping system : The internal check valve prevents any backflow of hot water.

Specifications

  • Connection: G 3/4" M/F
  • Opening pressure: 7 bar
  • Maximum operating pressure: 10 bar
  • Replenishment flow rate: > 4000 liters/hour
  • Maximum discharge capacity: 10kW
  • Conforming to EN 1487
  • Accreditations: Belgaqua, NF, ACS

Accessories

Siphon for pressure safety group, type: SSG

Artikelen

Artikelselectie-assistent
Type
Lengte [mm]
Spleten
Aansluitmaat
Artikelnummer Type Lengte [mm] Spleten Aansluitmaat E-shop
A04650T120625 GYP-P-LINE - 1 - L= 625 MM - A 625 1 A
A04650T120A00 GYP-P-LINE - 1 - L=1000 MM - A 1000 1 A
A04650T120C50 GYP-P-LINE - 1 - L=1250 MM - A 1250 1 A
A04650T220625 GYP-P-LINE - 2 - L= 625 MM - B 625 2 B
A04650T220A00 GYP-P-LINE - 2 - L=1000 MM - B 1000 2 B
A04650T220C50 GYP-P-LINE - 2 - L=1250 MM - B 1250 2 B
A04650T320625 GYP-P-LINE - 3 - L= 625 MM - C 625 3 C
A04650T320A00 GYP-P-LINE - 3 - L=1000 MM - C 1000 3 C
A04650T320C50 GYP-P-LINE - 3 - L=1250 MM - C 1250 3 C
=> Voorraadproduct centraal magazijn behoudens verkoop

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...