ACA-DX-HP • DX Surface Mounted Air Curtain

The surface-mounted air curtains ACA-DX-HP are equipped with EC fans and are specially designed for connection to Fujitsu inverter heat pumps with direct expansion. The sleek and modern air curtain is designed for use in shops and public areas where users do not want to worry about the air curtain and where maintaining high energy efficiency and comfort levels is required.

The ACA-DX-HP is available in three different capacities for door heights up to 3 m. The 3 lengths can be combined to provide a solution for every door width.

This type of air curtain is equipped with a state of the art bypass system, which creates a pleasant air jet even during the inevitable defrost cycle of the heat pump, without consuming any extra energy.

The air curtain is standard equipped with a wired control that makes it possible to control the ventilation speed in 5 positions and that is equipped with a door contact indication, various LED indicators, an automatic/manual mode and an on/off button for heating. The power supply board is also equipped with a GBS input (potential-free contact) and GBS output (potential-free contact) for external control.

Application

  • Hospitals
  • Shops
  • Office buildings
  • Hotel lobbies

Specifications

  • Only heating
  • Cooling on request
  • EC fans

Material

  • Steel casing
  • Remote control in a PVC casing for surface mounting : dimensions 70x70x26 mm

Colour

  • RAL 9016 (traffic white). Other colors available on request

Mounting

  • Suited for surface mounting on the ceiling

Accessoires

  • Communication module, type ACA-DX-BOX
  • Door contact
  • Connection to GBS by use of an external contact
  • Master/Slave control possible with RJ45 cable. Max. 30 m. (to provide on site)

Text for tender

Copy
The surface-mounted air curtain has a state of the art bypass system, which creates a pleasant air jet even during the inevitable defrost cycle of the heat pump, without consuming extra energy. Thanks to this system, the air flow during the defrost cycle is not directed through the cold heat exchanger of the air curtain, but through the suction at the top of the air curtain. This temporarily uses the unused heat from the ceiling area to effectively shield the opening. After the heat pump has completed the defrost cycle, the air flow in the air curtain is returned to the heat exchanger.

The fan is controlled by a 5-speed remote control, supplied with the air curtain. This type of air curtain is only suitable for heat pump applications with Fujitsu inverter controlled outdoor units. The housing is painted in steel in RAL 9016, other colors are available on request. Up to 9 air curtains can be controlled in master/slave using an RJ45 cable and a wired control. This air curtain is GBS-ready and standard equipped with an external input contact, a door input contact and an operation and error output contact.

Technical data

  12
18
24
Lengthcm100150200250100150200250100150200250
Mounting height (Max.)m< 2,30< 2,60< 3,00
Dimensions (HxL)°mm330 x 620
Outlet range  +30°/-30°
Air flow data of air curtain
Effective air flow ratem³/h140018002700360018002700360045002700360054006300
Sound pressure level**dB(A)40-5441-5641-5841-6041-5443-5644-5845-6040-5441-5641-5841-60
Weightkg4971951155075100120497195115
Electrical data of fans
Power supply (50 Hz)°°V230/1
Absorbed power (Max.)kW0,420,630,841,050,420,841,051,260,420,630,841,05
Absorbed current (Max.)A1,72,63,44,31,83,44,35,01,72,63,44,3
Power cable sectionmm²3G 2,5
Automatic fuse (Slow)A10
Technical data of DX battery (H)
Heating capacity @ 20/35°C*** kW6,99,313,418,79,113,418,222,312,217,927,232,3
Refrigerant R410A
Battery diameter inch1/2-5/81/2-7/81/2-5/81/2-7/8
Technical data of matching Fujitsu outdoor unit
Type of unit (AOYG/A) 30 LETL36 LETL45 LATT60 LATT36 LETL45 LATT60 LATT72 LRLA36 LATT60 LATT72 LRLA90 LRLA
Type of ACA-DX-BOX ACA-DX-BOX 30ACA-DX-BOX 36ACA-DX-BOX 45ACA-DX-BOX 60ACA-DX-BOX 36ACA-DX-BOX 45ACA-DX-BOX 60ACA-DX-BOX 72ACA-DX-BOX 36ACA-DX-BOX 60ACA-DX-BOX 72-
Power supplyV230/1400/3230/1400/3
Absorbed power (Nom. - Max.)kW2,68-3,83,1-4,53,8-5,85,1-7,13,1-4,53,8-5,85,1-7,16,2-9,82,8-5,15,1-7,16,2-9,88,2-12,1
Absorbed current (Nom. - Max.)A11,7-1713,6-205,5-117,6-12,513,6-25,5-117,6-12,59,6-22,84,4-8,57,6-12,59,6-22,812-25,8
Dimensions (Height)mm830830129012908301290129016901290129016901690
Dimensions (Length)mm900900900900900900900930900900930930
Dimensions (Depth)mm330330330330330330330760330330760760
Sound pressure leveldB(A)555554565554565753565759
Weightkg616110410461104104215104104215215
Cooling pipes1inch3/8-5/81/2-7/83/8-5/81/2-7/8
Amount of prefilled refrigerantg210021003450345021003450345011200345034501120011200
Extra amount of refrigerantg/m404050504050501105050110110
Numbre of prefilled metersm402049051797,55
Maximum length/heigth of cooling pipes²m40/2030/3045/3040/3040/3065/3050/3065/3075/3065/3070/3065/30
Minimum length of cooling pipesm555555555555
Cable section between air curtain and outdoor unitmm²4G 1,5
Power cable sectionmm²3G 43G 45G 2,55G 2,53G 45G 2,55G 2,55G 45G 2,55G 2,55G 45G 4
Automatic fuse (Slow)A252516162516162516162525
* Specifications and design are subject to change for further improvement without prior notice
** The sound pressure level is measured at 3m distance of the air curtain's air intake at high speed
*** Heating capacity at 20°C air intake temperature and 35°C air outlet temperature at a condensation temperature between 43 and 50°C
° Fan connection on the left side when standing in front of the device
1 Always use the same cooling pipes as the outdoor unit
² Minimum 5m of cooling pipes between the air curtain and the Fujitsu outdoor unit

Technical data

Refill (gr) *12-1000 R12-1500 R12-2000 R12-2500 R18-1000 R18-1500 R18-2000 R18-2500 R18-1000 R18-1500 R18-2000 R18-2500 R
Type of outdoor unit30 LETL36 LETL45 LATT60 LATT36 LETL45 LATT60 LATT72 LRLA36 LATT60 LATT72 LRLA90 LRLA
5m3043014041030x140xxxxx
10m23063039066023030390560x30290560
15m4308306409104302806401110x2808401110
20m63010308901160630530890166013053013901660
25m8301230114014108307801140221038078019402210
30m10301430139016601030103013902760630103024902760
35m1230-164019101230128016403310880128030403310
40m1430-1890216014301530189038601130153035903860
45m--2140--1780214044101380178041404410
50m-----2030239049601630203046904960
55m-----2280-55101880228052405510
60m-----2530-60602130253057906060
65m-----2780-66102380278063406610
70m--------2630-6890-
75m--------2880---
gr/m404050504050401105050110110
x = No extra refill required
- = Unauthorized length of cooling pipes still possible for this combination
* = Minimum 5m of cooling pipes between the air curtain and the Fujitsu outdoor unit