SOLANO CEILING • Recessed air curtains

Ceiling curtains with less visual impact by discrete installation

Application

  • Representative rooms like stores, restaurants, showrooms, etc. SOLANO CEILING units are designed for installation in suspended ceilings. Their advantage is possibility of installation in existing ceiling without cutting additional holes.

Specifications

  • 3 lengths - 1, 1,5 and 2 meter
  • 3-speed motor
  • 4 meter range*
  • Adjustable air stream
  • Integrated in the ceiling
  • Cross flow fan
  • Controlled by thermostat with S-C or S-TOUCH
  • Door switch operation
  • Enhanced automation in standard
  • BMS ready
  • Various operation modes
  • Different operation modes MASTER-SLAVE connection
*Vertical range of isothermal stream (at velocity boundary equal to 2,0 m/s)

Accessoires

  • Touchscreen control, type S-TOUCH
  • Room thermostat for SOLANO, type S-C
  • Motorised hydraulic valve, QCV-2 and QCV-3
  • Motorised hydraulic valve, S-V-2 and S-V-3

Articles

Article selection assistant
Type
Code supplier
Article number Type Code supplier E-shop
J083501042200 VAPACYL 422 D1-2L222 / PCM1-2L-2WO
J083501052200 VAPACYL 522/922 D1-2N235 / PCD1-2N-2WA
J083501053400 VAPACYL 534/934 D1-2H335
J083501183400 VAPACYL 1834 D3N335 / PCM3N-3WA
J083501303400 VAPACYL 3034 D4N355 / PCD4N-3WB
J083501456400 VAPACYL 4564 D4N655 / PCD4N-6WB
=> Stock product central warehouse, except sales

Technical data

  Ceiling W-100Ceiling N-100Ceiling E-100Ceiling W-150Ceiling N-150Ceiling E-150Ceiling W-200Ceiling N-200Ceiling E-200
Power supply[V/Hz]230/50230/503 x 400/50230/50230/503x400/50230/50230/503x400/50
Power consumption[kW]0.340.427.50.360.4411.50.380.4915.5
Current consumption[A]1.51.9111.6216.61.72.222.4
Heating capacity[kW]11.9 -720.5 -1127.7 -15
IP 212121212121212121
Connection["]1/2" - -1/2" - -1/2" - -
Air flow[m³/h]260035002600400048004000520066005200
Sound level (1)[dB(A)]586058596059616361
Max. heating water temp.[°C]95 - -95 - -95 - -
Max. operating pressure[MPa]1.6 - -1.6 - -1.6 - -
Air temperature rise (2)(∆T) [°C]15 -1115 -1216 -13
Weight[kg]32.331.734.541.238.942.45047.253.2
Weight of unit filled with water[kg]33.1 - -42.4 - -51.6 - -
Range (3)[m]555555555
(1) Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m³, at distance of 3 m from the unit
(2) For CEILING-W at inlet/outlet water temperature 90/70°C and inlet air temperature 10°C / for CEILING-E at inlet air temperature 10°C
(3) Range of vertical isothermal air stream, at velocity limit above 2 m/s

Order example

CEILING W-100
W = curtain with water heater exchanger
N = curtain without heater exchanger (ambient)
E = curtain with electric heaters