PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

SOLANO CEILING • Recessed air curtains

Ceiling curtains with less visual impact by discrete installation

Application

  • Representative rooms like stores, restaurants, showrooms, etc. SOLANO CEILING units are designed for installation in suspended ceilings. Their advantage is possibility of installation in existing ceiling without cutting additional holes.

Specifications

  • 3 lengths - 1, 1,5 and 2 meter
  • 3-speed motor
  • 4 meter range*
  • Adjustable air stream
  • Integrated in the ceiling
  • Cross flow fan
  • Controlled by thermostat with S-C or S-TOUCH
  • Door switch operation
  • Enhanced automation in standard
  • BMS ready
  • Various operation modes
  • Different operation modes MASTER-SLAVE connection
*Vertical range of isothermal stream (at velocity boundary equal to 2,0 m/s)

Accessoires

  • Touchscreen control, type S-TOUCH
  • Room thermostat for SOLANO, type S-C
  • Motorised hydraulic valve, QCV-2 and QCV-3
  • Motorised hydraulic valve, S-V-2 and S-V-3

Artikelen

Article selection assistant
Type
Volume [L]
Article number Type Volume [L] E-shop
J050801010012 HEV 12 12
J050801010018 HEV 18 18
J050801010024 HEV 24 24
J050801010035 HEV 35 35
=> Stock product central warehouse, except sales
=> Stock product local warehouses, except sales

Technical data

  Ceiling W-100Ceiling N-100Ceiling E-100Ceiling W-150Ceiling N-150Ceiling E-150Ceiling W-200Ceiling N-200Ceiling E-200
Power supply[V/Hz]230/50230/503 x 400/50230/50230/503x400/50230/50230/503x400/50
Power consumption[kW]0.340.427.50.360.4411.50.380.4915.5
Current consumption[A]1.51.9111.6216.61.72.222.4
Heating capacity[kW]11.9 -720.5 -1127.7 -15
IP 212121212121212121
Connection["]1/2" - -1/2" - -1/2" - -
Air flow[m³/h]260035002600400048004000520066005200
Sound level (1)[dB(A)]586058596059616361
Max. heating water temp.[°C]95 - -95 - -95 - -
Max. operating pressure[MPa]1.6 - -1.6 - -1.6 - -
Air temperature rise (2)(∆T) [°C]15 -1115 -1216 -13
Weight[kg]32.331.734.541.238.942.45047.253.2
Weight of unit filled with water[kg]33.1 - -42.4 - -51.6 - -
Range (3)[m]555555555
(1) Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m³, at distance of 3 m from the unit
(2) For CEILING-W at inlet/outlet water temperature 90/70°C and inlet air temperature 10°C / for CEILING-E at inlet air temperature 10°C
(3) Range of vertical isothermal air stream, at velocity limit above 2 m/s

Order example

CEILING W-100
W = curtain with water heater exchanger
N = curtain without heater exchanger (ambient)
E = curtain with electric heaters

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...