PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

S-ECM • Extended control system for SOLANO

  • Accessories
  • Accessory for SOLANO air curtain

The control unit dedicated to SOLANO air curtains. Control module delivered in set which enables connection to S-TOUCH controller and integration with SOLANO SYSTEM

Application

  • For SOLANO EASY, SOLANO DESIGN and SOLANO INDUSTRY

Specifications

  • Integration to the SOLANO SYSTEM
  • Communication with BMS (MODBUS RTU)
  • The works programs
    • K1 programm – Signal from door switch or thermostat is main signal for the device to run
    • K2 programm – Signal from door switch is main signal for the device to run and thermostat is in charge of valve/heaters
  • Connection to the door switch S-DS-MAG/S-DS-MEC
  • Connection to the controller S-C/S-TOUCH
  • The ability to cennect devices MASTER-SLAVE
  • Ability to cennect ext. temp. sensor (PT-1000)

Artikelen

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035530012010 UTV-10/L/2P 3.83 5.02 2 AC Vertical Left
J035530012020 UTV-20/L/2P 7.05 8.61 2 AC Vertical Left
J035530012030 UTV-30/L/2P 9.2 11.3 2 AC Vertical Left
J035530012040 UTV-40/L/2P 10.6 12.94 2 AC Vertical Left
J035530012050 UTV-50/L/2P 13.1 16.99 2 AC Vertical Left
J035530013010 UTV-10/R/2P 3.83 5.02 2 AC Vertical Right
J035530013020 UTV-20/R/2P 7.05 8.61 2 AC Vertical Right
J035530013030 UTV-30/R/2P 9.2 11.3 2 AC Vertical Right
J035530013040 UTV-40/R/2P 10.6 12.94 2 AC Vertical Right
J035530013050 UTV-50/R/2P 13.1 16.99 2 AC Vertical Right
J035530014110 UTV-10/L/4P 3.6 4.18 4 AC Vertical Left
J035530014120 UTV-20/L/4P 7.00 7.01 4 AC Vertical Left
J035530014130 UTV-30/L/4P 9.01 9.16 4 AC Vertical Left
J035530014140 UTV-40/L/4P 9.57 10.60 4 AC Vertical Left
J035530014150 UTV-50/L/4P 13.63 12.65 4 AC Vertical Left
J035530015010 UTV-10/R/4P 3.6 4.18 4 AC Vertical Right
J035530015020 UTV-20/R/4P 7.00 7.01 4 AC Vertical Right
J035530015030 UTV-30/R/4P 9.01 9.16 4 AC Vertical Right
J035530015040 UTV-40/R/4P 9.57 10.60 4 AC Vertical Right
J035530015050 UTV-50/R/4P 13.63 12.65 4 AC Vertical Right
J035530022010 UTC-10/L/2P 3.83 5.02 2 AC Horizontal Left
J035530022020 UTC-20/L/2P 7.05 8.61 2 AC Horizontal Left
J035530022030 UTC-30/L/2P 9.20 11.33 2 AC Horizontal Left
J035530022040 UTC-40/L/2P 10.60 12.94 2 AC Horizontal Left
J035530022050 UTC-50/L/2P 13.10 16.99 2 AC Horizontal Left
J035530023010 UTC-10/R/2P 3.83 5.02 2 AC Horizontal Right
J035530023020 UTC-20/R/2P 7.05 8.61 2 AC Horizontal Right
J035530023030 UTC-30/R/2P 9.20 11.33 2 AC Horizontal Right
J035530023040 UTC-40/R/2P 10.60 12.94 2 AC Horizontal Right
J035530023050 UTC-50/R/2P 13.10 16.99 2 AC Horizontal Right
J035530032010 UTC-10/L/4P 3.60 4.18 4 AC Horizontal Left
J035530032020 UTC-20/L/4P 7 7.01 4 AC Horizontal Left
J035530032030 UTC-30/L/4P 9.01 9.16 4 AC Horizontal Left
J035530032040 UTC-40/L/4P 9.57 10.60 4 AC Horizontal Left
J035530032050 UTC-50/L/4P 13.63 12.65 4 AC Horizontal Left
J035530033010 UTC-10/R/4P 3.60 4.18 4 AC Horizontal Right
J035530033020 UTC-20/R/4P 7 7.01 4 AC Horizontal Right
J035530033030 UTC-30/R/4P 9.01 9.16 4 AC Horizontal Right
J035530033040 UTC-40/R/4P 9.57 10.60 4 AC Horizontal Right
J035530033050 UTC-50/R/4P 13.63 12.65 4 AC Horizontal Right
*According to Eurovent at highest speed 0Pa

Technical data

Temp. range-10 ÷ 60 [o C]
IP54
InstallationOn wall installation
Max. cable cross2,5 mm²
Weight0,75 kg
ColourLight grey

  • Before any installation work, you must disconnect the power supply from the S-ECM
  • S-ECM can only be installed indoors
  • The input signal control should be completed sleeves
  • The input signal control should be selected by the designer