White fire resistant ventilation exhaust valves with thermal fuse of 70°C and fire resistance class EI60(veo->i)S
Application
For ventilation purposes and fire compartimentation in walls with fire resistance of 60 minutes
Material
Steel
Colour
White, RAL 9010
Construction
Composition
Steel body with white powder coated finish
Moulded fireproof heat-resistant material
Disc in ceramic felt
Threaded rod
Central core in powder coated steel
Standard mounting frame in galvanized steel
Locking device
Threaded support with fuse
Fuse-hook
Return spring in steel
Fuse 70°C
Locking clips
x: total length when locked (after exposure to heat)
Mounting
The valve should be mounted in a brick wall or partition gypsum plaster, according to the following methodology:
Make a reservation DN + 40 mm in the wall crossing. Ø particular case of a partition gypsum: spare a square booking dimension (DN 70) x (DN 70) therein a trimmer with a headband Promatect'H thickness 15mm.
Fix the pipe in DN standardized circular, to the mounting flange.
Position and the wedge together in the center of the book so that the folded edge of the flange comes into bare outer face of the receiving valve.
Grouting periphery coated with gypsum mixed with sand.
Adjusting the opening of the movable part of the valve (see graphs)
Install the valve set in the standby position, in its collar by rotating 1/4 turn: to build on the outer edge of the body: do not put stress on the central core!
Certification
CE Certified under the name BCF-2-EI60S
CE certified 1812-CPD-1039
Conforme according EN15650-2010
Classification EI60(veo->i)S
Service pressure 300Pa
Fuse tested according ISO 10294-4
Accessories
Mountingframe (included)
End of range switch, type FDC DVS-B+K
Text for tender
The ventilation valves will be fire resistant EI60(veo->i)S with thermal fuse of 70° and equipped with mountingframe.
Finished white, RAL 9010
type DVS-B+K
The ventilation valves will be fire resistant EI60(veo->i)S with thermal fuse of 70° and equipped with mountingframe.
Finished white, RAL 9010
type DVS-B+K
Order example
DVS-B + K, 125
Explanation
DVS-B+K = Type of fire resistant valve
125 = Connection diameter
Articles
Article selection assistant
Connection diameter [mm]
Article number
Type
Connection diameter [mm]
E-shop
A06132T100000
GYP-SQUARE 100
100
A06132T125000
GYP-SQUARE 125
125
=> Stock product central warehouse, except sales
Quick selection
Q
DVS-B+K
100
125
s
3
6
9
12
3
6
9
12
30
Ps
40
12
Lw(A)
32
25
40
Ps
75
25
45
Lw(A)
40
25
27
60
Ps
50
18
100
30
Lw(A)
44
35
40
25
80
Ps
32
18
51
Lw(A)
43
36
34
100
Ps
50
28
80
35
Lw(A)
50
42
42
32
120
Ps
40
51
24
Lw(A)
48
39
32
140
Ps
70
30
Lw(A)
48
36
180
Ps
50
Lw(A)
45
Selection graphs
Symbols and specifications
Q = Air volume in m³/h
Ps = Static pressure in Pa
s = Distance between the central cone and the body of the valve in mm