PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

RENOVENT EXCELLENT • HRU system D ≤ 450 m³/h

Heat recovery units with counter-flow heat exchanger. The range consists of several types for air flow ranges from 100 to 450 m³/h.

Brand

  • Brink

Application

  • Ventilation with heat recovery for residential and non-residential applications

  • Indoor mounting in a frost-free area

Composition

  • Casing in prelacquered steel plate
  • Round connections with diameter 125/160/180 mm
  • Excellent 300 - 400 - 450: automatic 100% bypass
  • Excellent 180 without bypass and electric pre-heater
  • Condensation tray and drain with connexion dia 32 mm
  • Inner casing in EPS foam for thermal and acoustic insulation
  • The Plus version is a unit with extra regulation possibilities for several applications such as CO2

Fan

  • Single inlet centrifugal fan EBM Papst from the latest generation
  • Direct driven EC-motor

Exchanger

  • Static counter-flow heat exchanger made of plastic
  • Efficiency: according to NBN EN 308 downloadable
  • Complete and automatic bypass (only type 300 - 400 - 450)
  • Intelligent anti-frost regulation with triac driven electrical pre-heater (only type 300 - 400 - 450)

Filter

  • Standard Renovent Excellent with two G3 filters

Options

  • Renovent Excellent Plus:

Certification

  • The unit is tested according to NBN EN 308 (www.epbd.be)
  • Passive house certificat

Accessories

  • 4-positions switch with filter indication, type CVREN 4
  • Replacement filters, type FSREN
  • Enthalpy changer, type WTW-H
  • RF remote control (4 positions) with receiver, type RFREN
  • Regulating module with timer function, type DCREN AC
  • Demand controlled ventilation, type DCV
  • Stench trap, type SIP 32
  • Electric post-heater, type CVR-NE (plus version)
  • Humidity sensor, type HRT REN
  • CO2-sensor, type CO2 REN E-BUS
  • Cable for Renovent, type RJ12
  • Mounting chairs, type MC
  • ModBus module, type REN MODBUS

Order example

RENOVENT EXCELLENT PLUS 400 R 4/0

Explanation

  • RENOVENT EXCELLENT = type of heat recovery unit
  • 400 = max airflow m³/h
  • R = right configuration, L = left configuration
  • 4/0 = 4 connections on top, 2/2 = 2 connections on top and 2 at the bottom
  • Plus = version with extra regulation possibilities

Technical data

  Q [m³/h]P [W]Lwa [dB(A)]
  

Lwa2

Lwa5

Lwa6
Renovent Excellent 180Vmin50 @ 7-16Pa16 - 18   
V175 @ 18-40Pa24 - 2632

31

49
V2100 @ 30-68Pa30 - 4239

37

56
V3150 @ 60-150Pa62-8648

45,50

66
Vmax180 @ 150Pa116   
Renovent Excellent 300Vmin50 @ 3-7Pa9 - 9,2   
V1100 @ 11-28Pa13,7 - 15,2

30

3344
V2150 @ 26-66Pa22 - 29,2

38

3951
V3225 @ 56-142Pa46,8 - 66,2

44

4560
Vmax300 @ 150Pa104

50

5467
Renovent Excellent 400Vmin50 @ 3-6Pa8,60   
V1100 @ 6-20Pa9,5 - 1528,5030,5041,50
V2200 @ 25-49Pa29 - 4039,5045,5056
V3300 @ 56-178Pa72 - 985255,5065
Vmax400 @ 150Pa16653,505869,50
Renovent Excellent 450Vmin50 @ 2-5Pa9,5   
V1100 @ 5-15Pa11 - 1829,531,542,5
V2200 @ 20-60Pa32 - 4540,546,557
V3300 @ 40-130Pa80 - 1055156,566
V400 @ 150Pa17054,55970,5
Vmax450 @ 100Pa222---

Lwa2 = Sound power level enviromment

Lwa 5 = Sound power level @inlet

Lwa 6 = Sound power level @outlet

Energy efficiency class

 ManualSensorsClock / sensor
Renovent Excellent 180BAA
Renovent Excellent 300AA+A
Renovent Excellent 400AA+A
Renovent Excellent 450AAA

1: to the house 2: to outside 3: from the house

4: from outside 5: electrical connection 6: condensate drain

Dimensions

 H [mm]B [mm]D [mm]Ø [mm][kg]
Renovent Excellent 18060056030212525
Renovent Excellent 30076567756416038
Renovent Excellent 40076567756418038
Renovent Excellent 45076567756418038
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Requesting information. Please wait a moment...