PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

HTI DS170 Inverter • Inverter high temperature air/water heat pump with DHW tank 70°C

The HTI high temperature heat pump with a DS170 DHW tank is an environmentally friendly device that uses the natural refrigerant R290 (propane) to heat water up to 70°C. The indoor module consists of a DHW tank of 170 liters and a built-in hydraulic module. The unit guarantees good operation down to -20°C outside temperature. The HTI monoblock is a heating only appliance with an inverter compressor; The unit maintains its high COP values even at negative outside temperatures. The DS170 consists of a monobloc outdoor unit and an indoor module with a buffer tank of 50 liters. Its compactness is its great asset and makes it applicable in most places.

Brand

  • Auer - Intuis

Application

  • Production of domestic hot water
  • Floor heating
  • Fan coils

Composition

Outdoor: Monoblock heatpump type HTI70 6-8-11-14 kW with supplied:
  • Communication cable of 10 m long, between HTI/Pilote (3 core and already connected to HTI) (do not place along the power supply cables)
  • Flexible pipes (Durite) of 1 m long => rest of the hydraulic circuit in fixed insulated pipe to indoor module (diameter according the distance between these two, see table at the bottom of this page)
  • Ball valve with built-in filter for placement on the return connection.
  • Pressure relief valve (2,5 bar) to be installed at the hydraulic output of the heatpump.

Indoor module Pilote DS 170 D:
  • Primairy circulation pump between the HTI heatpump and this indoor module
  • Built-in pump for circulation of central heating water through underfloor heating, radiators or fan coil units
  • Hydraulic disconnection between primary and secondary circuit
  • Enamelled tank for domestic hot water of 170 liters with built-in heating coil
  • 3-way valve for automatic switchover between DHW and CH water
  • Cast iron back-up resistance 3 kW
  • Pressure sensor
  • Electronic controller
  • Water pressure sensor
  • Expansion vessel 8L (dimensioned for hydraulic piping between indoor and outdoor unit)
  • Vent valve
  • Replaceable magnesium anode built into this tank
  • Only for models DS170 11 or 14: included buffertank 25 L (to be placed in return line)

Refrigerant

  • Ecological and natural refrigerant Propane (R290) with a GWP value of only 3

Installation

  • The secondary water pump is selected by the installer depending on the consumer network.
  • The startup of the installation is always with a technician of CAIROX BELGIUM.
  • Safety group should be placed on the cold water supply pipe - connect to drain pipe.
  • The addition of an anti-corrosion agent or a glycol/anti-corrosion mixture is mandatory.

Accessories

  • Room thermostat, type TH HRC70
  • Low water temperature regulation, type Thorix
  • Clean existing heating systems first.
  • Commissioning (STRONGLY RECOMMENDED), type XSTARTUPJ quote on request

Applicable outdoor units

  • HTI 6-8-11-14 kW

Articles

Artikelselectie-assistent
Diameter D [mm]
Artikelnummer Type [mm] Diameter D [mm] E-shop
C011000000080 MTS 80 80
C011000000100 MTS 100 100
C011000000125 MTS 125 125
C011000000150 MTS 150 150
C011000000160 MTS 160 160
C011000000180 MTS 180 180
C011000000200 MTS 200 200
C011000000250 MTS 250 250
C011000000315 MTS 315 315
C011000000355 MTS 355 355
C011000000400 MTS 400 400
C011000000450 MTS 450 450
C011000000500 MTS 500 500
C011000000560 MTS 560 560
C011000000630 MTS 630 630
C011000000800 MTS 800 800
=> Voorraadproduct centraal magazijn behoudens verkoop
=> Voorraadproduct regionale filialen behoudens verkoop

Technical data

DS170 indoor module  
Dimensionsmm1725 x Ø 520
Weightkg80
Backup resistanceW2 x 1500
Power supplyV230 mono
Absorbed currentA23
Cable section 3G4
Fuse 25A
Hydraulic connections 6 x 3/4"
Maximum water pressure CHBar2.5
    
HTI outdoor unit HTI 6 monoHTI 8 mono
Maximum water temperature°C7070
Maximum heating capacitykW68
Nominal heating capacity +7°C/+35°CkW4.176.06
Absorbed power +7°C/+35°CkW0.831.13
COP +7°C/+35°C 5.675.35
Heating capacity -7°C/+70°CkW5.56.85
Energy class A++A++
Annual energy consumptionKWh/year25713134
Sound level according to EN 12102dB(A)5657
Refrigerant (GWP) R290 (3)
Amount of refrigerant R290kg0.420.6
Dimensions outdoor unitmm1035 x 820 x 4801035 x 1070 x 480
Weight outdoor unitkg9298
Nominal air flow ratem³/h35004500
Nominal water flow ratem³/h1.051.35
Hydraulic connection diametermm26/34 male
Operating range°C-15°C to +40°C
Maximum absorbed currentA1515
Power supply outdoor unit 230V
FuseA2020
Cable sectionmm²3G2,53G2,5
Power position OFF (POFF) 0.0030.003
Power thermostat OFF (PTO) 0.0050.005
Power in standby (PSB) 0.0030.003
Power carter heating (PCK) 0.0130.013

Notes

A: Return from the heat pump
B: Supply to the heat pump
C: Return from the heating circuit
D: Suplly to the heating circuit
E: Domestic cold water
F: Domestic hot water
G: Decoupling
LTP: Floor temperature limiter aquastat
Rt: Thermostatic valve
Rm: Manual valve
SECS: Sanitary probe
Sext: Outdoor sensor
TA: Room thermostat
SA: Room sensor
VF: Filter valve

1: Heat pump circulation pump
2: Circulation pump for circuit 1
4: Module flow sensor
5: Safety aquastat 110 ° C
6: Auxiliary immersion heater 3kW
7: Pressure sensor
8: 3 bar safety valve
9: 3-way valve
10: Expansion vessel 8 liters
11: Air vent (not supplied)
12: Electrical connection (not supplied)
13: Security group for sanitary cold water (not supplied)
14: Filling device (not supplied)

Dimensions

 DescriptionHydraulic connection
1Outgoing water heat pump1"
2Incoming water back-up boiler1"
3Emptying3/4"
4Outgoing water back-up boiler1"
5Incoming water circuit 11"
6Outgoing water circuit 11"
7Incoming water circuit 2 (optional)1"
8Outgoing water circuit 2 (optional)1"
9Incoming water (cold) to heat pump1"
10Safety valve for drainingNot provided
    
HTIMinimum required piping diameter
6 kW8 kW
If distance between heat pump and indoor module >10m[mm]22/2422/24
(or the equivalent of 20m linear pressure losses)
If distance between heat pump and indoor module >10m and <15m[mm]24/628/30
(or the equivalent of 30m lineair drukverlies)
If distance between heat pump and indoor module >15 and <25m[mm]28/3032/34
(or the equivalent of 50m linear pressure losses)
If distance between heat pump and indoor module >25m and <50m[mm]32/3436/38
(or the equivalent of 100m linear pressure losses)
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be