HPB-S 300 • Heat pump water heaters with extra heat exchanger (solar) floor model

Boiler heat pump for the production of domestic hot water. The heat pump is very energy efficient and has the A+ energy label. Sound insulation ensures silent operation of the boiler. The tank is made of enamelled steel and has a volume 293 liters, which allows the production of domestic hot water. The device is equipped with a micro-channel heat exchanger which are made of aluminum. The main advantage being the absence of contact with water.

Brand

  • R-AQUA

Application

  • Production of domestic hot water for household use

Product

  • Smart Grid Ready
  • Enemelled steel water tank of 293 liters (enamelling process at 860°C)
  • The aluminum heat exchanger of the heat pump is located around the water tank instead of in the water tank: this ensures a separation between the refrigerant and the domestic hot water
  • The S version is equipped with an additional heat exchanger for the connection of another heat source, for example solar panels.
  • Energy label A+ with a COP up to 3.02 according to EN16147
  • Low-noise operation of only 38.1 dB (A)
  • Production of domestic hot water possible from 38°C to 55°C (75°C with resistance)
  • Anti-legionella cycle
  • Heating capacity of the heat pump: 1,5 kW
  • Electric back-up resistance of 1,5 kW
  • Protection through a magnesium anode
  • Economy, smart or boost function
  • Holiday mode
  • Attention : The safety group (max. pressure 7 bar) is not included. To be provided by the installer and to be mounted on the cold water supply pipe - To be connected to the drain pipe.

Refrigerant

  • R290

Installation

  • Floor mounting

Accessories

  • WiFi module, type HPB(-S) WIFI
  • Insulation coupling, type ISC
  • Safety group, type PSG

  • Siphon for pressure safety group, type SSG

  • Expansion vessel for sanitary water, type SEV

  • Connection kit for sanitary expansion vessel, type EVC SAN

  • Pressure regulator, type PRV

  • Insulated duct (2m), type ISDR 200/170
  • Insulated bend, type ISDR BD90/45° 200/170
  • Connection piece, type ISDR M
  • Wall passage, type ISDR BLR 200/170
  • Roof passage, type ISDR DDI 200/170
  • Suspension bracket, type OBMC 200, for mounting of ducts with outer diameter 200

Articles

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] Hydraulic connection E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Left
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Left
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Left
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Left
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Left
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Left
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Right
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Right
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Right
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Right
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Right
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Right
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Left
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Left
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Left
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Left
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Left
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Left
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Right
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Right
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Right
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Right
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Right
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Right
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Left
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Left
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Left
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Left
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Left
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Left
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Right
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Right
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Right
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Right
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Right
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Right
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Left
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Left
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Left
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Left
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Left
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Left
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Right
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Right
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Right
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Right
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Right
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Right
Prices right version = prices left version

Technical data

  HPB-S 300
Volumel293
Max. heating capacity heat pump + electrical resistanceW3000
Heating capacity heat pump *W1500
Absorbed power compressorW410
Built-in electrical backup resistanceW1500
Operating temperature range°C-5 ~43
Temperature DHW with heat pump°C38 ~ 55
Flow ratem³/h350
Static fan pressure***Pa40
Sound pressure level at 1 mdB(A)38,10
Refrigerant (GWP) R290 (3)
Precharged quantity of refrigerantg(CO2eq-kg)150 (0,45)
Heating time*h9h19
COP (outdoor temperature +7°C)** 3,02
COP (indoor temperature +15°C)** 3,51
Seasonal energy efficiency ratio (outdoor temperature +7°C)**%124,70
Energy class (outdoor temperature +7°C)** A+
DimensionsmmØ640 X 1905 H
Weight (net)kg119
Connection diameter of air duct (supply/discharge)mm2 x 150
Hydraulic connection diameterinch3/4"
Power supplyV / Ph / Hz230/1/50
Automatic fuseA16
Protection class IPX1
Tank material Enamelled steel
Maximum operating pressure with safety groupbar7
Maximum temperature with electrical backup resistance°C75
Built-in heat exchanger1,5
Connection diameter built-in heat exchangerinch3/4''
* Test conditions: ambient temp.: 20°C D.B. /15°C W.B., water inlet/outlet temp.: 15°C /55°C
** Test conditions according to standard EN 16147: ambient temp.: 20°C D.B. /15°C W.B., water inlet/outlet temp.: 10°C /55°C
*** Static fan presure : possible up to 120 Pa, but this will change the sound pressure level up to 55 dB(A)

Dimensions

  HPB-S 300 R-AQUA
Amm1905
Bmm1467
Cmm1208
Dmm1088
Emm128
FmmØ640
GmmØ150
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be