PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

THORIX • Low and high water temperature regulation

  • Intuis - Auer
  • Air/water monoblock
  • Accessories

Thorix EVOLUTION is used for the regulation and distribution of a 2nd temperature circuit in the installation. This regulation makes it possible to work with 2 different water temperatures for both floor heating at low water temperature and a high water temperature for, for example, fancoils or radiators. A correct adjustment is obtained in combination with the room thermostat. The module can be used with the Auer monoblock heat pumps that are suitable for this appliance.

The module is equipped with an electronically controlled 3-way mixing valve for the adjustment of the 2 temperature circuits of, for example, radiators and floor heating and this depending on the outside temperature (with outside sensor) and the room temperature (with or without thermostat or interactive room sensor). It is equipped with a motorized 2-way valve that allows the circulation of the water from the heat pump to circuit No. 1 - radiators or floor heating, depending on the room temperature.

Brand

  • Auer - Intuis

Installation

Thorix EVOLUTION must be installed in an open area to allow cooling of its electronic components by means of natural ventilation. The ventilation openings on the bottom and top of the appliance must be free and open at all times. Do not install the device in a small space such as a closed cabinet. The maximum ambient temperature must not exceed 25°C. Allow a clearance of 50 mm on each side of the unit for easy removal of the casing.

Accessories

  • Thermostat for HRC TH HRC70

Applicable indoor units

  • Only to be applied in combination with the DS170 & HRC Premium+ heat pumps

Artikelen

Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type Cooling capacity [kW] Heating Capacity* [kW] # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035530012010 UTV-10/L/2P 3.83 5.02 2 AC Vertical Left
J035530012020 UTV-20/L/2P 7.05 8.61 2 AC Vertical Left
J035530012030 UTV-30/L/2P 9.2 11.3 2 AC Vertical Left
J035530012040 UTV-40/L/2P 10.6 12.94 2 AC Vertical Left
J035530012050 UTV-50/L/2P 13.1 16.99 2 AC Vertical Left
J035530013010 UTV-10/R/2P 3.83 5.02 2 AC Vertical Right
J035530013020 UTV-20/R/2P 7.05 8.61 2 AC Vertical Right
J035530013030 UTV-30/R/2P 9.2 11.3 2 AC Vertical Right
J035530013040 UTV-40/R/2P 10.6 12.94 2 AC Vertical Right
J035530013050 UTV-50/R/2P 13.1 16.99 2 AC Vertical Right
J035530014110 UTV-10/L/4P 3.6 4.18 4 AC Vertical Left
J035530014120 UTV-20/L/4P 7.00 7.01 4 AC Vertical Left
J035530014130 UTV-30/L/4P 9.01 9.16 4 AC Vertical Left
J035530014140 UTV-40/L/4P 9.57 10.60 4 AC Vertical Left
J035530014150 UTV-50/L/4P 13.63 12.65 4 AC Vertical Left
J035530015010 UTV-10/R/4P 3.6 4.18 4 AC Vertical Right
J035530015020 UTV-20/R/4P 7.00 7.01 4 AC Vertical Right
J035530015030 UTV-30/R/4P 9.01 9.16 4 AC Vertical Right
J035530015040 UTV-40/R/4P 9.57 10.60 4 AC Vertical Right
J035530015050 UTV-50/R/4P 13.63 12.65 4 AC Vertical Right
J035530022010 UTC-10/L/2P 3.83 5.02 2 AC Horizontal Left
J035530022020 UTC-20/L/2P 7.05 8.61 2 AC Horizontal Left
J035530022030 UTC-30/L/2P 9.20 11.33 2 AC Horizontal Left
J035530022040 UTC-40/L/2P 10.60 12.94 2 AC Horizontal Left
J035530022050 UTC-50/L/2P 13.10 16.99 2 AC Horizontal Left
J035530023010 UTC-10/R/2P 3.83 5.02 2 AC Horizontal Right
J035530023020 UTC-20/R/2P 7.05 8.61 2 AC Horizontal Right
J035530023030 UTC-30/R/2P 9.20 11.33 2 AC Horizontal Right
J035530023040 UTC-40/R/2P 10.60 12.94 2 AC Horizontal Right
J035530023050 UTC-50/R/2P 13.10 16.99 2 AC Horizontal Right
J035530032010 UTC-10/L/4P 3.60 4.18 4 AC Horizontal Left
J035530032020 UTC-20/L/4P 7 7.01 4 AC Horizontal Left
J035530032030 UTC-30/L/4P 9.01 9.16 4 AC Horizontal Left
J035530032040 UTC-40/L/4P 9.57 10.60 4 AC Horizontal Left
J035530032050 UTC-50/L/4P 13.63 12.65 4 AC Horizontal Left
J035530033010 UTC-10/R/4P 3.60 4.18 4 AC Horizontal Right
J035530033020 UTC-20/R/4P 7 7.01 4 AC Horizontal Right
J035530033030 UTC-30/R/4P 9.01 9.16 4 AC Horizontal Right
J035530033040 UTC-40/R/4P 9.57 10.60 4 AC Horizontal Right
J035530033050 UTC-50/R/4P 13.63 12.65 4 AC Horizontal Right
*According to Eurovent at highest speed 0Pa

Notes

Power consumption 4 to 70W depending on the speed.
Absorbed current 0.05 to 0.58A depending on the speed.

Notes

A = boiler inlet 3/4"
B = boiler outlet 3/4"
C = mixing circuit outlet 3/4"
D = direct circuit outlet 3/4"
E = mixing circuit return 3/4"
F = direct circuit return 3/4"

Notes

1 = View of protective covers removed
2 = Return sensor to boiler
3 = Boiler inlet sensor
4 = Flow sensor to heating circuit
5 = LTP (floor circuit only)
6 = Electrical supply of the motorized valve
  • brown wire on terminal 3
  • blue wire on terminal 4

Dimensions

Dimensional characteristics
Height286 mm
Width420 mm
Depth260 mm
Hydraulic connections3/4"
Weight10 kg
Maximum installation power18 kW
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...