PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

CGW-ID A1 • A2W heat pumps R32 with DHW heater

  • R-AQUA
  • Air/water split
  • Hydromodule + DHW
  • R32
  • 6 - 16 kW

Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.
The integrated water heater (185L) is made of enamelled steel to protect against corrosion on the inside. A anode will protect the tank against ionization.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Heating of domestic water

Composition

  • 3-way valve
  • Communication cable included
  • High efficiency plate heat exchangers
  • Energy-efficient circulation pumps
  • Integrated water heater with thermal stratification (185 liters)

  • Colour touch screen controller (wired)

  • Expansion vessel (10 liters)
  • Safety valve (3 bar)
  • Electrical backup heater
  • Electrical backup heater domestic water
  • electronic anode
  • Water pressure sensor

Refrigerant

  • R32

Specifications

  • Split system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 55°C at outside temperatures down to -10°C
  • A+++ at 35°C water temperature
  • Bivalent setup possible
    • The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.

  • Standard equipped with WiFi
  • Standard equipped with Modbus interface
  • Easy installation
  • EUROVENT EN 14511 and EN 14825 certification
  • Keymark certification

Accessories

  • Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Smart Grid module, type SMART GRID
  • Buffer tank, type BTE 60, BTE 100
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Safety group, type PSG

  • Siphon for pressure safety group, type SSG

  • Expansion vessel for sanitary water, type SEV

  • Connection kit for sanitary expansion vessel, type EVC SAN

  • Pressure regulator, type PRV

  • Coding plug for permanently disabling the cooling function, type COD-ID-H

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group and expansion vessel MUST be provided on site.

Applicable outdoor units

  • Outdoor unit, type CGW-OU A1

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right

Startup

  • Start-up by CAIROX BELGIUM strongly recommended

Technical data

Indoor unitCGW-ID 06 A1CGW-ID 08 A1CGW-ID 10 A1CGW-ID 12 A1CGW-ID 14 A1CGW-ID 16 A1
Corresponding outdoor unitCGW-OU 06 A1CGW-OU 08 A1CGW-OU 10 A1CGW-OU 12 A1CGW-OU 14 A1CGW-OU 16 A1
Heating capacity A7/W35kW6,008,0010,0012,0014,0015,50
COP A7/W35 5,004,974,765,004,704,50
Heating capacity A7/W45kW5,808,009,8512,4014,4816,09
COP A7/W45 3,823,863,673,773,683,62
Heating capacity A2/W35kW5,196,567,679,6011,2013,13
COP A2/W35 3,713,693,533,423,343,74
Heating capacity A2/W45kW5,066,407,489,3610,9213,13
COP A2/W45 2,972,952,832,742,673,13
Heating capacity A-7/W35kW4,285,416,337,688,9610,81
COP A-7/W35 2,932,922,792,702,632,74
Heating capacity A-7/W45kW4,155,256,147,448,6810,81
COP A-7/W45 2,342,332,232,162,112,21
Heating capacity A-10/W35kW3,894,925,756,727,8410,04
Heating capacity A-10/W45kW3,764,765,566,487,5610,04
SCOP W35/W55 4,53/3,254,60/3,304,60/3,254,63/3,234,65/3,504,60/3,50
Seasonal efficiency ηs heat pump W35/W55%179/127181/129181/127182/126183/137181/137
Annual energy consumption heat pump W35/W55kWh2729/31693149/43714038/50914967/69855535/80455886/8045
Energy class heat pump W35/W55 A+++/A++
Seasonal efficiency ηs DHW W55%116123123112112112
Annual energy consumption DHW W55kWh885831831915915915
Energy class DHW A

Power supply

V / Ph / Hz230/1/50
Refrigerant (GWP) R32 (675)
Refrigerant pipes (liquid - gas)inch1/4 - 1/21/4 - 5/8
Hydraulic connections (supply - return)inch1
Outgoing water temperaturesHeating°C20 ~ 60
Cooling°C7 ~ 25
DHW°C40 ~ 80
ComponentsPumpType-High-efficiency pump
Regulation-Electronic - continuous control
Capacity (min-max)W2 ~ 753 ~ 87
Flow rate (min)l/h650870870115011501150
Flow rate (nom)l/h103013801710206024102660
Expansion vesselVolume*l10
Pressure (max)bar3
Pre-pressurebar1
Electrical heatingType-Wet
Material-Incoloy825
Regulation-Automatic
Number of steps-2
CapacitykW36
CombinationkW1,5 + 1,53 + 3
Heat exchangerType-Plate heat exchanger
Number-2
Water tankVolumeL185
Electrical resistancekW3
Sound pressure**dB (A)29
Power cable section indoor unitmm²3G2,53G6
Automatic fuse (slow)A2032
DimensionsUnit (LxDxH)mm600x650x1800
Weightkg195
Specifications and design can be modified for further improvement without prior notice
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...