PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

PAS Kp • Reversible heatpumps air/water on propane

  • Chillers and Heatpumps
  • Air/Water Heatpump
  • EMICON
  • 36 - 295 kW 44 - 344 kW
  • R290

Reversible heatpump Air/Water on propane for the production of chilled/hot water. The units are equipped with semi-hermetic reciprocating compressors. Axial 6-pole fans. Suitable for outdoor installation. Refrigerant R290 (GWP 3) (propane) These units are specially designed for cooling medium to large projects. Tandem technology offers multiple capacity stages and increases efficiency at part load. This also improves performance. Leak detector and ATEX certified fan in compartment with cooling circuit included as standard. Mandatory commissioning by CAIROX.

Brand

  • Emicon

Application

  • Outdoor air/water reversible heatpumps suitable for comfort and process cooling and heating applications

Characteristics

  • Cooling capacity: 36 to 295 kW
  • Heating capacity: 44 to 344 kW

Composition

  • Refrigerant gas R290 with a GWP of 3
  • Semi-hermetic reciprocating compressors
  • Power supply 400/3/50
  • Microprocessor controller
  • Leak detector included as standard
  • ATEX certified fan in compartment with cooling circuit
  • Copper/Aluminium battery with Bluefin coating

Options

  • PW Softstart compressors by part winding
  • RM Prepainted protective coating on the fins on the air coil
  • PM Vibration Dampers with Springs
  • PA Rubber Vibration Dampers
  • BF Operation up to outdoor temperatures of -20°C
  • MF Phase Sequence Relay
  • PQ Remote Control
  • RA Anti-frost resistance with thermostat on the evaporator
  • VSC inverter control on the compressors
  • TE Electronic expansion valve(s)
  • CFU Sound-Absorbing Enclosure Around the Compressors
  • RF Correction on the cos phi by capacitor(s)
  • GP Protective grid on the battery
  • IH RS 485, IH BACNET, SNMP, TCP/IP, MODBUS…
  • I1 Insulation Shells for Placement Around Victaulic Joints

Versions

  • PAS. Kp
Standard version with Blue Fin coating on coil

Order example

PAS 451 Kp
Explanation
45 = Nominal cooling capacity (KW)
1 = Number of cooling circuits
Kp = Propane Refrigerant

Artikelen

Artikelselectie-assistent
Type
Koelvermogen* [kW]
Verwarmingsvermogen* [kW]
Wateraansluiting
Artikelnummer Type Koelvermogen* [kW] Verwarmingsvermogen* [kW] Wateraansluiting E-shop
J036151900001 Romeo-ECM-1M-NC/L/2P 0.70 0.87 Links
J036151900002 Romeo-ECM-2M-NC/L/2P 1.49 1.77 Links
J036151900003 Romeo-ECM-3M-NC/L/2P 2.04 2.34 Links
J036151900004 Romeo-ECM-4M-NC/L/2P 2.53 2.78 Links
J036151900005 Romeo-ECM-5M-NC/L/2P 2.84 3.12 Links
J036151900006 Romeo-ECM-6M-NC/L/2P 3.19 3.60 Links
J036151901001 Romeo-ECM-1M-NC/R/2P 0.70 0.87 Rechts
J036151901002 Romeo-ECM-2M-NC/R/2P 1.49 1.77 Rechts
J036151901003 Romeo-ECM-3M-NC/R/2P 2.04 2.34 Rechts
J036151901004 Romeo-ECM-4M-NC/R/2P 2.53 2.78 Rechts
J036151901005 Romeo-ECM-5M-NC/R/2P 2.84 3.12 Rechts
J036151901006 Romeo-ECM-6M-NC/R/2P 3.19 3.60 Rechts
J036151910001 Romeo-ECM-1M-RC/L/2P 0.70 0.87 Links
J036151910002 Romeo-ECM-2M-RC/L/2P 1.49 1.77 Links
J036151910003 Romeo-ECM-3M-RC/L/2P 2.04 2.34 Links
J036151910004 Romeo-ECM-4M-RC/L/2P 2.53 2.78 Links
J036151910005 Romeo-ECM-5M-RC/L/2P 2.84 3.12 Links
J036151910006 Romeo-ECM-6M-RC/L/2P 3.19 3.60 Links
J036151911001 Romeo-ECM-1M-RC/R/2P 0.70 0.87 Rechts
J036151911002 Romeo-ECM-2M-RC/R/2P 1.49 1.77 Rechts
J036151911003 Romeo-ECM-3M-RC/R/2P 2.04 2.34 Rechts
J036151911004 Romeo-ECM-4M-RC/R/2P 2.53 2.78 Rechts
J036151911005 Romeo-ECM-5M-RC/R/2P 2.84 3.12 Rechts
J036151911006 Romeo-ECM-6M-RC/R/2P 3.19 3.60 Rechts
J036151920001 Romeo-ECM-1M-RC/TD/L/2P 0.70 0.87 Links
J036151920002 Romeo-ECM-2M-RC/TD/L/2P 1.49 1.77 Links
J036151920003 Romeo-ECM-3M-RC/TD/L/2P 2.04 2.34 Links
J036151920004 Romeo-ECM-4M-RC/TD/L/2P 2.53 2.78 Links
J036151920005 Romeo-ECM-5M-RC/TD/L/2P 2.84 3.12 Links
J036151920006 Romeo-ECM-6M-RC/TD/L/2P 3.19 3.60 Links
J036151921001 Romeo-ECM-1M-RC/TD/R/2P 0.70 0.87 Rechts
J036151921002 Romeo-ECM-2M-RC/TD/R/2P 1.49 1.77 Rechts
J036151921003 Romeo-ECM-3M-RC/TD/R/2P 2.04 2.34 Rechts
J036151921004 Romeo-ECM-4M-RC/TD/R/2P 2.53 2.78 Rechts
J036151921005 Romeo-ECM-5M-RC/TD/R/2P 2.84 3.12 Rechts
J036151921006 Romeo-ECM-6M-RC/TD/R/2P 3.19 3.60 Rechts
J036151930001 Romeo-ECM-1M-RC/TD/App/L/2P 0.70 0.87 Links
J036151930002 Romeo-ECM-2M-RC/TD/App/L/2P 1.49 1.77 Links
J036151930003 Romeo-ECM-3M-RC/TD/App/L/2P 2.04 2.34 Links
J036151930004 Romeo-ECM-4M-RC/TD/App/L/2P 2.53 2.78 Links
J036151930005 Romeo-ECM-5M-RC/TD/App/L/2P 2.84 3.12 Links
J036151930006 Romeo-ECM-6M-RC/TD/App/L/2P 3.19 3.60 Links
J036151931001 Romeo-ECM-1M-RC/TD/App/R/2P 0.70 0.87 Rechts
J036151931002 Romeo-ECM-2M-RC/TD/App/R/2P 1.49 1.77 Rechts
J036151931003 Romeo-ECM-3M-RC/TD/App/R/2P 2.04 2.34 Rechts
J036151931004 Romeo-ECM-4M-RC/TD/App/R/2P 2.53 2.78 Rechts
J036151931005 Romeo-ECM-5M-RC/TD/App/R/2P 2.84 3.12 Rechts
J036151931006 Romeo-ECM-6M-RC/TD/App/R/2P 3.19 3.60 Rechts
* (Koeling) Binnen temp.: 27°C ruimtetemp. - Waterregime.: 7°C ingaand /12°C uitgaand op middensnelheid (Verwarming) Binnen temp.: 20°C - Waterregime.: 45°C ingaand /40°C Uitgaand op middensnelheid.

Specifications

PAS Kp 45152165173188110011201150217022102250229023402
Cooling capacitykW36.244.653.660.574.889.6103129148180208247295
Total power input CoolingkW12.514.416.319.12429.535.439.947.358.670.778.195.9
Water flowm³/h6.237.689.2210.4112.8715.4217.7222.1725.4630.9135.7642.4950.75
Water pressure dropkPa32.242.425.431.51520.526.413.517.224.421.829.523.6
Heating capacitykW44.452.764.47287.6106123148173214247289344
Total power input HeatingkW11.513.714.816.921.525.630.13441.251.758.367.284.3
Refrigerant type (GWP) R290 (3.3)
Precharged refrigerant chargekg(CO2eq-kg)7(0.0231)9(0.0297)13(0.0429)13(0.0429)14(0.0462)17(0.0561)17(0.0561)19(0.0627)26(0.0858)33(0.1089)33(0.1089)41(0.1353)51(0.1683)
SCOP 3.283.273.563.473.373.453.353.33.263.283.293.383.27
Water flowm³/h7.669.0911.1212.4315.1418.3621.325.529.9137.0442.6950.1859.42
Water pressure dropkPa37.751.734.742.318.52633.916.922.633.428.738.430.7
Sound pressure leveldB(A)52535357596161616163636363
Cooling capacity: Outdoor temperature 35°C - chilled water temperature in/out 12/7°C
Heating capacity: Outdoor temperature 7°C - water temperature in/out 30/35°C
Sound pressure level calculated according to ISO 3744 at 10 m distance from the unit

Dimensions

PAS Kp 45152165173188110011201150217022102250229023402
L[mm]1620162026602660266026602660370037004850485058905890
W[mm]1370137013701370137013701370137013701370137013701370
H[mm]2420242024202420242024202420242024202420242024202420
Gewicht/Poids[kg]88294612581280135014161466179818762246236629183106

Prices

Detailed selection / quotation available on request

Operational limits
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be