PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

PAS Kp • Reversible heatpumps air/water on propane

  • Chillers and Heatpumps
  • Air/Water Heatpump
  • EMICON
  • 36 - 295 kW 44 - 344 kW
  • R290

Reversible heatpump Air/Water on propane for the production of chilled/hot water. The units are equipped with semi-hermetic reciprocating compressors. Axial 6-pole fans. Suitable for outdoor installation. Refrigerant R290 (GWP 3) (propane) These units are specially designed for cooling medium to large projects. Tandem technology offers multiple capacity stages and increases efficiency at part load. This also improves performance. Leak detector and ATEX certified fan in compartment with cooling circuit included as standard. Mandatory commissioning by CAIROX.

Brand

  • Emicon

Application

  • Outdoor air/water reversible heatpumps suitable for comfort and process cooling and heating applications

Characteristics

  • Cooling capacity: 36 to 295 kW
  • Heating capacity: 44 to 344 kW

Composition

  • Refrigerant gas R290 with a GWP of 3
  • Semi-hermetic reciprocating compressors
  • Power supply 400/3/50
  • Microprocessor controller
  • Leak detector included as standard
  • ATEX certified fan in compartment with cooling circuit
  • Copper/Aluminium battery with Bluefin coating

Options

  • PW Softstart compressors by part winding
  • RM Prepainted protective coating on the fins on the air coil
  • PM Vibration Dampers with Springs
  • PA Rubber Vibration Dampers
  • BF Operation up to outdoor temperatures of -20°C
  • MF Phase Sequence Relay
  • PQ Remote Control
  • RA Anti-frost resistance with thermostat on the evaporator
  • VSC inverter control on the compressors
  • TE Electronic expansion valve(s)
  • CFU Sound-Absorbing Enclosure Around the Compressors
  • RF Correction on the cos phi by capacitor(s)
  • GP Protective grid on the battery
  • IH RS 485, IH BACNET, SNMP, TCP/IP, MODBUS…
  • I1 Insulation Shells for Placement Around Victaulic Joints

Versions

  • PAS. Kp
Standard version with Blue Fin coating on coil

Order example

PAS 451 Kp
Explanation
45 = Nominal cooling capacity (KW)
1 = Number of cooling circuits
Kp = Propane Refrigerant

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right

Specifications

PAS Kp 45152165173188110011201150217022102250229023402
Cooling capacitykW36.244.653.660.574.889.6103129148180208247295
Total power input CoolingkW12.514.416.319.12429.535.439.947.358.670.778.195.9
Water flowm³/h6.237.689.2210.4112.8715.4217.7222.1725.4630.9135.7642.4950.75
Water pressure dropkPa32.242.425.431.51520.526.413.517.224.421.829.523.6
Heating capacitykW44.452.764.47287.6106123148173214247289344
Total power input HeatingkW11.513.714.816.921.525.630.13441.251.758.367.284.3
Refrigerant type (GWP) R290 (3.3)
Precharged refrigerant chargekg(CO2eq-kg)7(0.0231)9(0.0297)13(0.0429)13(0.0429)14(0.0462)17(0.0561)17(0.0561)19(0.0627)26(0.0858)33(0.1089)33(0.1089)41(0.1353)51(0.1683)
SCOP 3.283.273.563.473.373.453.353.33.263.283.293.383.27
Water flowm³/h7.669.0911.1212.4315.1418.3621.325.529.9137.0442.6950.1859.42
Water pressure dropkPa37.751.734.742.318.52633.916.922.633.428.738.430.7
Sound pressure leveldB(A)52535357596161616163636363
Cooling capacity: Outdoor temperature 35°C - chilled water temperature in/out 12/7°C
Heating capacity: Outdoor temperature 7°C - water temperature in/out 30/35°C
Sound pressure level calculated according to ISO 3744 at 10 m distance from the unit

Dimensions

PAS Kp 45152165173188110011201150217022102250229023402
L[mm]1620162026602660266026602660370037004850485058905890
W[mm]1370137013701370137013701370137013701370137013701370
H[mm]2420242024202420242024202420242024202420242024202420
Gewicht/Poids[kg]88294612581280135014161466179818762246236629183106

Prices

Detailed selection / quotation available on request

Operational limits
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...