EVEREST R290 PAE Kp • Modular air/water heat pumps extra heating/cooling

  • Heatpumps
  • Air/water monoblock
  • Emicon
  • Modular units
  • C 66,3 - 663 kW / H 88,9 - 889 kW
  • R290
  • Optimized for heating

The EVEREST290 PAE Kp is a modular air/water heat pump with 2 pipes that is suitable for heating and cooling. Compared to the air/water heat pump PAE 881 WA Kp, this version has a plate exchanger and air-side battery that have been optimized for heating. The heating capacity of this unit is slightly higher than the "WA" version, but its greatest asset is the outgoing water temperature of up to 70°C. Up to 10 of these modules can be placed in a cascade system. The monoblock unit is filled with the natural refrigerant propane (R290).
The EVEREST290 is an appliance for heating and cooling that uses 2 scroll compressors with the same capacity. This ensures 2 power stages and low power consumption. Due to the specific construction, the appliance will switch to defrost mode less quickly and the defrost cycle is completed as efficiently as possible.
The unit maintains its high COP values ​​even at negative outside temperatures.

Brand

  • Emicon

Application

  • Production of domestic hot water (up to 70°C)
  • Heating or cooling in commercial applications
  • Heating or cooling in industrial applications

Characteristics

Per module:
  • PAE 881 Kp: Cooling capacity: 66,3 kW / Heating capacity: 88,9 kW
  • In heating mode:
Outgoing water temperature of 70°C at 0°C outdoor temperature
Outgoing water temperature of 58°C at -20°C outdoor temperature
  • In cooling mode with glycol:
Outgoing water temperature down to 0°C at -20°C outdoor temperature

Composition

  • Modules of 2-pipe monoblock heat pumps that can be used stand-alone or in a cascade of maximum 10 units
  • Reliable operation
  • Maintenance-free propane leak detector
  • Strong, compact, steel structure with powder coating RAL 7035
  • Movable with hand pallet truck
  • 2 EC fans
  • 2 Scroll compressors in tandem with crankcase heating in a soundproof casing
  • Electronic expansion valve
  • Insulated stainless steel plate exchanger with flow switch
  • Copper/aluminium batteries mounted in V with innovative mini-channel technology and hydrophilic coating
  • Winter regulation down to -20°C
  • Phase monitor
  • Plug-and-play hydraulic and electrical connections

Options

  • Rubber anti-vibration mounts. Type PA-Kp (PAE GPE)
  • Anti-vibration mounts with springs. Type PM-Kp (PAE GPE)
  • Soundproofing jacket on compressors. Type Cl-Kp (PAE GPE)
  • Ampere and voltmeter used to measure the electrical current absorbed and the electrical supply voltage of the unit. Type A+V-Kp (PAE GPE)
  • Tablet interface kit in combination with KGR5/10 or KGH/10 kit in modular use. Type KTA-Kp (PAE GPE)
  • Remote display. Type PQ-Kp (PAE GPE)
  • Water collector kit without insulation (1 per unit). Type KCA-Kp (PAE)
  • Insulation for water collector. Type KCC-Kp (PAE)
  • Gateway framework kit for 2 to 5 units in modular use (1 in case of multiple units). Type KG5-Kp (PAE GPE)
  • Gateway framework kit for 6 to 10 units in modular use (1 in case of multiple units). Type KG10-Kp (PAE GPE)
  • Gateway kit for stand-alone unit with Hi-web and Wi-Fi router. Type KGH1-Kp (PAE GPE)
  • Gateway board kit for 2 to 5 units in modular use with Hi-web and Wi-Fi router (1 case of multiple units). Type KGH5-Kp (PAE GPE)
  • Gateway board kit for 6 to 10 units in modular use with Hi-web and Wi-Fi router (1 in case of multiple units). Type KGH10-Kp (PAE GPE)
  • Gateway kit for stand-alone unit with Wi-Fi router. Type KGR1-Kp (PAE GPE)
  • Gateway board kit for 2 to 5 units in modular use with Wi-Fi router (1 in case of multiple units). Type KGR5-Kp (PAE GPE)
  • Gateway board kit for 6 to 10 units in modular use with Wi-Fi router (1 in case of multiple units). Type KGR10-Kp (PAE GPE)
  • Display interface kit for monitoring leak detector. Type KLD-Kp (PAE GPE)
  • Electrical switch and connection board for a kit up to 5 modules (connect main power here in case of cascade). Type KP5-Kp (PAE GPE)
  • Electrical switch and connection board for a kit up to 10 modules (connect main power here in case of cascade). Type KP10-Kp (PAE GPE)
  • Victaulic cap + socket kit/welded. Type KTT-Kp (PAE GPE)
  • Lifting brackets securely attached to the frame to lift the unit with hooks and cables. Type MG-Kp (PAE GPE)
  • Manometers in front panel. Type MT-Kp (PAE GPE)
  • Anti-freeze tracing around the evaporator. Type RA-Kp (PAE)
  • Double insulation around the evaporator. Type VB-Kp (PAE)
  • Anti-freeze tracing around the internal hydraulic pipes. Type VH-Kp (PAE)

Versions

  • PAE 881 Kp
  • PAE 881 WA Kp

Order example

  • PAE 881 Kp
Explanation
88

=

Nominal heating capacity (kW)

1 = Number of cooling circuits

Kp = Propane refrigerant

Articles

Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number Type # pipes AC or EC engine Horizontal or vertical Hydraulic connection E-shop
J035520030010 FRESH-H-1/L/2P 2 AC Horizontal Left
J035520030012 FRESH-V-1/L/2P 2 AC Vertical Left
J035520030020 FRESH-H-2/L/2P 2 AC Horizontal Left
J035520030022 FRESH-V-2/L/2P 2 AC Vertical Left
J035520030030 FRESH-H-3/L/2P 2 AC Horizontal Left
J035520030032 FRESH-V-3/L/2P 2 AC Vertical Left
J035520030040 FRESH-H-4/L/2P 2 AC Horizontal Left
J035520030042 FRESH-V-4/L/2P 2 AC Vertical Left
J035520030050 FRESH-H-5/L/2P 2 AC Horizontal Left
J035520030052 FRESH-V-5/L/2P 2 AC Vertical Left
J035520030060 FRESH-H-6/L/2P 2 AC Horizontal Left
J035520030062 FRESH-V-6/L/2P 2 AC Vertical Left
J035520030070 FRESH-H-7/L/2P 2 AC Horizontal Left
J035520030072 FRESH-V-7/L/2P 2 AC Vertical Left
J035520031010 FRESH-H-1/R/2P 2 AC Horizontal Right
J035520031012 FRESH-V-1/R/2P 2 AC Vertical Right
J035520031020 FRESH-H-2/R/2P 2 AC Horizontal Right
J035520031022 FRESH-V-2/R/2P 2 AC Vertical Right
J035520031030 FRESH-H-3/R/2P 2 AC Horizontal Right
J035520031032 FRESH-V-3/R/2P 2 AC Vertical Right
J035520031040 FRESH-H-4/R/2P 2 AC Horizontal Right
J035520031042 FRESH-V-4/R/2P 2 AC Vertical Right
J035520031050 FRESH-H-5/R/2P 2 AC Horizontal Right
J035520031052 FRESH-V-5/R/2P 2 AC Vertical Right
J035520031060 FRESH-H-6/R/2P 2 AC Horizontal Right
J035520031062 FRESH-V-6/R/2P 2 AC Vertical Right
J035520031070 FRESH-H-7/R/2P 2 AC Horizontal Right
J035520031072 FRESH-V-7/R/2P 2 AC Vertical Right
J035520032010 FRESH-H-1/L/4P 4 AC Horizontal Left
J035520032012 FRESH-V-1/L/4P 4 AC Vertical Left
J035520032020 FRESH-H-2/L/4P 4 AC Horizontal Left
J035520032022 FRESH-V-2/L/4P 4 AC Vertical Left
J035520032030 FRESH-H-3/L/4P 4 AC Horizontal Left
J035520032032 FRESH-V-3/L/4P 4 AC Vertical Left
J035520032040 FRESH-H-4/L/4P 4 AC Horizontal Left
J035520032042 FRESH-V-4/L/4P 4 AC Vertical Left
J035520032050 FRESH-H-5/L/4P 4 AC Horizontal Left
J035520032052 FRESH-V-5/L/4P 4 AC Vertical Left
J035520032060 FRESH-H-6/L/4P 4 AC Horizontal Left
J035520032062 FRESH-V-6/L/4P 4 AC Vertical Left
J035520032070 FRESH-H-7/L/4P 4 AC Horizontal Left
J035520032072 FRESH-V-7/L/4P 4 AC Vertical Left
J035520033010 FRESH-H-1/R/4P 4 AC Horizontal Right
J035520033012 FRESH-V-1/R/4P 4 AC Vertical Right
J035520033020 FRESH-H-2/R/4P 4 AC Horizontal Right
J035520033022 FRESH-V-2/R/4P 4 AC Vertical Right
J035520033030 FRESH-H-3/R/4P 4 AC Horizontal Right
J035520033032 FRESH-V-3/R/4P 4 AC Vertical Right
J035520033040 FRESH-H-4/R/4P 4 AC Horizontal Right
J035520033042 FRESH-V-4/R/4P 4 AC Vertical Right
J035520033050 FRESH-H-5/R/4P 4 AC Horizontal Right
J035520033052 FRESH-V-5/R/4P 4 AC Vertical Right
J035520033060 FRESH-H-6/R/4P 4 AC Horizontal Right
J035520033062 FRESH-V-6/R/4P 4 AC Vertical Right
J035520033070 FRESH-H-7/R/4P 4 AC Horizontal Right
J035520033072 FRESH-V-7/R/4P 4 AC Vertical Right

Specifications

EVEREST PAE 881 Kp
Nominal cooling capacity (EN14511) (1)kW66,3
Total input power in cooling (EN14511)kW26,4
Total nominal current per module in coolingA50,8
EER (EN14511) 2,51*
Number of refrigerant circuits 1
Number of compressors 2
Number of axial fans 2
Total air flow rate of axial fans (1)m³/h35.390
Total fan input power (1)kW1,8
Total fan input current (1)A3,3
Number of plate exchangers 1
Total water flow rate of plate exchangerm³/h11,3
Pressure dropkPa27,4*
Diameter of hydraulic connectionsDN2" Victaulic*
Total pump input power P1 (1)kW0,73
Pump input current P1 (1)A1,4
Total pump electrical input power P1 (1)kW0,2
Nominal heating capacity (EN14511) (2)kW88,9
Total input power in heating (EN14511)kW22,2
Total nominal current in heatingA45,9
SCOP (3) 3,87*
COP (EN14511) 4,00*
Total air flow rate of axial fans (2)m³/h32.480
Total fan input power (2)kW1,6
Total fan input current (2)A3
Total water flow rate of plate exchanger (2)m³/h 
Pressure dropkPa43,6*
Diameter of hydraulic connectionsDN2" Victaulic*
Total electric pump input power P1 (2)kW0,8
Pump input current P1 (1)A1,6
Total pump electrical input power P1 (2)kW0,3
Refrigerant charge R290kg6,1
Global warming potential (GWP) 3
Equivalent CO2 chargekg18,3
Transport weightkg835
Operating weightkg840
Lengthmm2.560*
Depthmm1100
Heightmm2.450*
Sound power level (4)dB(A)87**
Sound pressure level (5)dB(A)55**
Power supplyV/Ph/Hz400/3/50+PE
The specified values apply to the following conditions:
(1) Fluid: water - In/Out temperature: 7/12°C - outside air 35°C
(2) Fluid: water - In/Out temperature: 30/35°C - outside air 7°C RH 87%.
(3) Calculated according to EU.813/2013.
(4) Sound power level in accordance with ISO 3744.
(5) Sound pressure level at 10 m from the unit in free field conditions in accordance with ISO 3744.
Technical data relating to the unit. In case of a modular system with n units, multiply the data (exept those marked with "*" ) by n to obtain the total values.
** In case of modular system see paragraph with sound data.

Specifications

Sound data EVEREST 290
Octave bands63 Hz125 HZ250 HZ500 HZ1000 HZ2000 HZ4000 HZ8000 HZLwLp1Lp10
PAE 881 Kp43 dB(A)51 dB(A)69 dB(A)76 dB(A)79 dB(A)84 dB(A)76 dB(A)63 dB(A)86,5 dB(A)68,3 dB(A)54,6 dB(A)
In the case of a modular system consisting of 1 to n modules, the total value of the sound level can be estimated by the following formula:
Leq tot= 10 x log 10 [n x ( 10 LW1/10)]